You are on page 1of 5

Job Number Job Title Software Consultants (Pty) Ltd Internet: http://www.prokon.com E-Mail : mail@prokon.

com Client Calcs by Checked by Date

Sheet

General column design


General column design by PROKON. Design code : CP65 - 1999
(GenCol Ver W2.4.12 - 02 Apr 2009)

C13

Input tables
General design parameters:
Code + c + b + b + b + b + b + b + b + b + b + b + b + b + b + b + b + b + b + b + b + b 500.000 391.200 40.000 350.740 40.000 286.378 40.000 202.500 40.000 104.822 40.000 0.000 40.000 -104.822 40.000 -202.500 40.000 -286.378 40.000 -350.740 40.000 -391.200 40.000 -405.000 40.000 -391.200 40.000 -350.740 40.000 -286.378 40.000 -202.500 40.000 -104.822 40.000 0.000 40.000 104.822 40.000 202.500 40.000 -350.740 -391.200 -405.000 -391.200 -350.740 -286.378 -202.500 -104.822 0.000 104.822 202.500 286.378 350.740 391.200 405.000 391.200 350.740 286.378 202.500 104.822 X/Radius or Bar dia. (mm) Y (mm) Angle ()

Job Number Job Title Software Consultants (Pty) Ltd Internet: http://www.prokon.com E-Mail : mail@prokon.com Client Calcs by Checked by Date

Sheet

+ b + b + b + b

286.378 40.000 350.740 40.000 391.200 40.000 405.000 40.000

-286.378 -202.500 -104.822 0.000

Design loads:
Load case 1 Designation Ultimate limit state design loads P (kN) Mx top (kNm) My top (kNm) Mx bot (kNm) My bot (kNm) 3500
CP65 - 1999

General design parameters:


Given: Lo = 5.000 m fcu = 40 MPa fy = 460 MPa Ac = 716423 mm Assumptions: (1) The general conditions of clause 3.8.1 are applicable. (2) The specified design axial loads include the self-weight of the column. (3) The design axial loads are taken constant over the height of the column.

Y
500

X 0

-500

-500

Design approach:
The column is designed using the following procedure: (1) The column design charts are constructed. (2) The design axis and design ultimate moment are determined . (3) The design axial force and moment capacity is checked on the relevant design chart.

Check column slenderness:


End fixity and bracing for bending about the Design axis: At the top end: Condition 1 (fully fixed). At the bottom end: Condition 1 (fully fixed). The column is braced. = 0.75 Effective column height: le = Lo = 3.750 m Check if the column is slender: le/h = 4.4 < 15 The column is short.
3.8.1.3

500

Table 3.21

Initial moments:
The initial end moments about the X-X axis: M1 = Smaller initial end moment = 0.0 kNm M2 = Larger initial end moment = 3500.0 kNm

Job Number Job Title Software Consultants (Pty) Ltd Internet: http://www.prokon.com E-Mail : mail@prokon.com Client Calcs by Checked by Date

Sheet

The initial moment near mid-height of the column : Mi = 0.4M1 + 0.6M2 0.4M2 = 2100.0 kNm The initial end moments about the Y-Y axis: M1 = Smaller initial end moment = 0.0 kNm M2 = Larger initial end moment = 0.0 kNm The initial moment near mid-height of the column : Mi = 0.4M1 + 0.6M2 0.4M2 = 0.0 kNm

3.8.3.2

3.8.3.2

Design ultimate load and moment:


Design axial load: Pu = 0.0 kN

Moments about X-X axis( kNm) Mxtop=3500.0 kNm

Mx=3500.0 kNm Mxmin=0.0 kNm

Mxbot=-0.0 kNm Initial Additional Design

Moments about Y-Y axis( kNm) Mytop=0.0 kNm

My=0.0 kNm Mymin=0.0 kNm

Mybot=-0.0 kNm Initial Additional Design


3.8.2.4

Check for miminum eccentricity: Check that the eccentricity exceeds the minimum in the plane of bending: Use emin = 20mm Mmin = 0.0 kNm about the Y-Y axis.

Job Number Job Title Software Consultants (Pty) Ltd Internet: http://www.prokon.com E-Mail : mail@prokon.com Client Calcs by Checked by Date

Sheet

Design of column section for ULS:


The column is checked for applied moment about the design axis. Through inspection: the critical section lies at the bottom end of the column. The design axis for the critical load case 1 lies at an angle of 0.00 to the X-axis The safety factor for the critical load case 1 is 1.00 For bending about the design axis:

Interaction Diagram 22E3 20E3 18E3 16E3 14E3 12E3 10E3 8000 6000 4000 2000
Moment max = 4168 kNm @ 5560kN

Axial load (kN)

-4500

-4000

-3500

-3000

-2500

-2000

-1500

-1000

1000

1500

2000

2500

3000

3500

4000

0 kNm 0.00

0 kN

-2000 -4000 -6000 -8000 -10E3 -12E3

Bending moment (kNm)

Moment distribution along the height of the column for bending about the design axis: At the top, Mx = 3500.0 kNm Near mid-height, Mx = 2100.0 kNm At the bottom, Mx = 0.0 kNm

4500

-500

500

Job Number Job Title Software Consultants (Pty) Ltd Internet: http://www.prokon.com E-Mail : mail@prokon.com Client Calcs by Checked by Date

Sheet

Stresses at the bottom end of the column for the critical load case 1

CP65 - 1999

Y
500

D X

0.0

D X 0

-500
-500

Summary of design calculations:


Design table for critical load case:
Moments and Reinforcement for LC 1: Top Madd-x Madd-y Mx My M' (kNm) 0.0 (kNm) 0.0 (kNm) 3500.0 (kNm) 0.0 (kNm) 3500.0 0.00 1.07 4.04 % (mm) 2866 Middle 0.0 0.0 2100.0 0.0 2100.0 0.00 1.78 30159 4.04 % 2866 Bottom -0.0 -0.0 -0.0 -0.0 0.0 0.00 1.00 30159 4.04 % 2866

Design axis () Safety factor Asc Percentage AsNom

(mm) 30159

Critical load case: LC 1

Design results for all load cases:


Load case Load case 1 Axis X-X Y-Y N (kN) 0.0 M1 (kNm) M2 (kNm) Mi (kNm) Madd (kNm) Design 0.0 0.0 3500.0 0.0 2100.0 0.0 0.0 0.0 Bottom M (kNm) M' (kNm) 3500.0 0.0 0.0 Safety factor 1.000

500