TE Temperature Controller

1 Panel Illustrations(Patent Panel)


Display measuring value (-199 999)
or display parameters.
Display set value or parameter value.
Alarm output lamp:ON:alarm active,
OFF:no alarm output.
Parameters select/confirm keyAt
measuring estate, set key is used as
modifying set value.
" " decrease key, " " increase key
"AT":press"AT"key for 3 seconds to start or stop PIDAuto-tune.
Auto-tuning indicating lamp:ON:auto-tuning
OFF:auto-tuning not active
Output indicating lamp:ON:Output active
OFF:Output not active
Applications:
TE PID temperature controller can be used for temperature measuring , displaying , alarm ,
adjust and control, with optional output module ( Relay, SSR, SCR), widely applied in
the temperature control systems in all the industries.
2 Features
2.1 Input signals:Thermocouple T/C:K(0 999 ) E(0 999 ) 1(0 999 ) T(0 400 )
RTD:Pt100(-199 600 ) Cu100(-50 150 ),It can be selected by sofeware,(Cu50 input must be
mentioned when order).
2.2 Control output: R: RELAY; S: SSR; K: SCR selected by software. To change different output just
need to change output mode in the controller.
2.3 Auxiliary conrtol output:one relay high value alarm output.Capacity 250VAC/3Aor 30V DC/3A.
2.4 Sampling rate: 0.5S.
2.5 Accuracy: 0.5F.S. 2digit
2.6 Power:TE6 TE7 TE9:220V/110VAC 15,TE4:85 265VAC/DC,50 60HZ,Consumption<5VA.
3 Ordering Code
TE -
10:1 loop input E,1,K,T,Pt100,Cu100
Alarm Output: B: 1 alarm
Control output: R: RELAY output
S: SSR output
K: SCR output
Default:Auto PID controller
Power Supply:Default:110V/220VAC (TE4: 85-265V AC/DC)
Size:4:48W 48H 6:48W 96H 7:72W 72H 9:96W 96H (mm)
TE Temperature Controller
Code Output Alarm
YES
YES
YES
Control Output
TE -RB10
TE -SB10
TE -KB10
TE -
Relay
SSR control output
SCR control output
KK051A-1(A/5)
IF above model can not be satisfied,the customers should
provide specification for special model.
4 Panel Illustrations(Patent Panel)
Code
D
A
C
Size
F
E
G
H
Size
Code
TE4
TE6
TE7
TE9
A B C D E F G H
44+0.5
44+0.5
67.5+0.8
91+0.5
44+0.5
91+0.5
67.5+0.8
91+0.5
30
25
30
25
25
30
14
30
48
48
72
96
48
96
72
96
5
12
12
12
100
100
100
100
Y
A
L
E
R
19
18
17
16
15
14
13
7
6
5
4
3
2
18
17
+
-
SSR
19
17
T
G
SCR
7
6 +
TC
TE7( Please indicate the power supply is AC 110V or AC220V when order)
1
AL
220V/110V( 10)
NC
NO
4
3
7
6
2
1
9
8
7
6
85 265VAC/DC
G
T
TE4
Rt
5
TC/mV
NC
NO
Y
A
L
E
R AL1
4
3
5
3
SSR
Rt
A
B
B
A
B
B
10
10
11
12
13
14
15
16
1
2
3
4
5
6
14
15
+
-
TC
TE9
7
AL
8
9
17
18
19
110V
220V
( 10)
Y
A
L
E
R
NO
NC
7
8
+
-
SSR
7
9
T
G
SCR
20
19
18
17
16
15
14
13
16
15
12
11
10
9
8
7
6
5
4
3
2
110V
4
3
+
-
R
S
S
4
2
T
G
R
C
S
AL
+
-
TC
TE6
1
220V
( 10)
Y
A
L
E
R
NO
NC
Rt
A
B
B
Rt
A
B
B
If any changes,please subject to the connection diagram on the product.
ATTENTION:OVERCURRENT PROTECTION DEVICES,EXTERNAL FUSES(suggest 245V AC/100mA)
OR CIRCUIT BREAKER (suggest 245V AC/100mA) ARE REQUIRED TO BE NEAR THE EQUIPMENT.
5 Key operation:
5.1 Press "SET" key for 3 seconds, enter the PID parameter adjust menu.
5.2 Press "SET" key to select the parameter you want to modify, then press "AT" key, LED flashes,
press "AT" key again to shift the digit. Then press " or " key to increase or decrease the
value. At last, press SET key to confirm the value. Press "SET" key again to move to the next
parameter it also go back to the measuring estate.
5.3 The unit will go back to measuring estate without key operation for 25 seconds. Or press "SET"
key for 3 seconds, it also go back to the measuring estate.
KK051A-2(A/5)