epro • System III MB Moisture / Gas Barrier Patent Pending

Excellent Strength and Durability • Exceptional Chemical Resistance • Seamless System • Fully Bonded to Slab • Redundant Protection

System Description
System III MB is a field installed composite
waterproofing and gas vapor barrier that is comprised
of a water-based polymer modified asphalt (PMA)
membrane sandwiched between two HDPE and
polypropylene fabric laminate sheets which provides
the durability and chemical resistance of HDPE with the
constructability and installation efficiencies of a PMA.
(See below for special designs for water table
conditions.)

System Components

Ecoshield-P (Base Course) – An HDPE film laminated


with a nonwoven polypropylene fabric geo-membrane.
Ecoline-S (Middle Course) – A spray or fluid applied,
water based polymer modified asphalt membrane. Excellent Strength and Durability – The result of the
Ecoshield-PP (Top Course) – Same as Ecoshield-P unique field installed composite design.
except with micro-perforations.
Exceptional Chemical Resistance – The HDPE films
System Components (Water Table Design) are very resistant to most contaminates including
Ecoshield-PB -(Replaces Ecoshield-PP) - A VOCs.
geocomposite membrane comprised of polypropylene
fabric and bentonite granules laminated to an HDPE Seamless System – The fluid applied component
sheet to provide self sealing characteristics and makes the transition details and field barrier a
puncture resistance. monolithic installation.

Additional Information Fully Bonded to Slab – The geo-textile surface of the


barrier mechanically interlocks with the concrete
Specifications – Reference “Specification Beneath Slab slab to form a permanent bond between the
Moisture Barrier” barrier and slab.
Detail Drawings – Reference all “MB” labeled Details
Installation Guidelines – Reference “Moisture Barrier Redundant Protection – Multiple waterproofing and
Installation” and “Repair Procedures – Moisture gas vapor barriers as well as protection courses.
Barrier”
OF DIFFE
Product Information –Reference “Ecoline-S”, “Ecoline- W
OR
LD RE
N
CE
A

R”, “Ecoshield-P”, "Beneath Slab Gas Vapor Barrier"


product brochures
S
FO

ON
R

TI

W a te r p r oo f i n g Sys tems EA I
R

LW ND
ORLD CO

800-882-1896 • www.eproserv.com
rev. sys3-mb_042111
epro • System III MB - Moisture / Gas Barrier
Epro Below Slab Water / Gas Barrier Composite System Testing
Composition HDPE film and polypropylene fabric laminate and polymer modified asphalt and HDPE film and
polypropylene fabric laminate. ( Ecoshield-P / Ecoline-S / Ecoshield-PP )

Tensile Strength* ......................... ASTM D-412 ..... 662 psi Chemical Permeation** .... ASTM F-739 Perm Rate Perm Rate
Elongation* .................................. ASTM D-412 ..... 45% Ug/cm2 ml/day
Adhesion to Concrete*** .............. ASTM C-836 .... 27 lbf/in Chlorinated Solvent
Puncture Resistance .................... ASTM D-1709 ... 310.9 lbs Perchloroethylene ................................... 69.4 .......... 0.0008
Hydrostatic Pressure ................... ASTM D-5385 ... 369.5 ft. Trichloroethylene ........ ............................ 89.8 .......... 0.0012
Aromatic Hydrocarbon
Soil Burial* ................................... ASTM D-4068 Benzene .................... ............................ 59.3 .......... 0.0013
Weight change ..................... See Note 1 ........ 1.2% ......... passed
Tensile Strength ................... See Note 1 ........ 9.89% ....... passed Chemical Resistance** ...... ASTM D-543 Net change
Elongation ............................ See Note 1 ........ 2.2% ......... passed Chlorinated Solvents .. ASTM D-882 Mod. (Less 10% pass)
Perchloroethylene
Heat Aging* ................................. ASTM D-4068 Weight ........................ ............................. 4.1%
Tensile Strength .................. See Note 1 ....... 8.6% ......... passed Tensile Strength ......... ............................. 6.5%
Elongation .......................... See Note 1 ....... 8.9% ......... passed Tricholorethylene
Weight ........................ ............................. 5.4%
Environmental Stress Cracking* .. ASTM D-1693 Tensile Strength ......... ............................. 6.0%
Failure ................................ See Note 2 ........ 620 hrs. .... passed
Aromatic Hydrocarbon
Oil Resistance* .......................... ASTM D-543 & Benzene
ASTM D-412 Weight ........................ ............................. 4.1%
Weight change ............................ See Note 1 ....... 7.6% ......... passed Tensile Strength ......... ............................. 4.4%
Tensile Strength ................. See Note 1 ....... 1.1% ......... passed
Elongation .......................... See Note 1 ....... 4.4% ......... passed Gases
Hydrogen Sulfide
Methane Transmission* .............. ASTM D-1434 Weight ........................ ............................. 0.6%
See Note 3 ....... 3.70xE-15.. passed Tensile Strength ......... ............................. 0.8%

* Tests performed by SGS / US Testing W


OR
LD
OF DIFFE
RE
N
CE
A

** Tests performed by TRI Environmental


*** Tests performed by Momentum Technologies