MicroWave trouble shooting - simple guide


www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

MicroWave Troubleshooting procedure


Step 1: Observe the led lights state of SCC&PXC board,
If
The lights work normally The lights are all dead Then Go to step 2 Check the power supply of the site

The power of the site is abnormal

Contact the site engineer and resume the power supply. Replace the PXC board ,if not resume ,replace the SCC board.

The power of the site is normal

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 2

MicroWave Troubleshooting procedure


Step 2: Check the NE current alarms, especially for the
following alarms orderly:

Volt _los RADIO_TSL_HIGH/LOW HARD_BAD IF_CABLE_OPEN BD_STATUS

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 3

1. VOLT_LOS
step1

Step2 Check the power switch of the ODU.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 4

1. VOLT_LOS

Step 3 Check the IF fiber jumper, IF cable, or ODU section by

section for a short circuit.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 5

2. Radio_tsl_low or high

Step1 The ODU which reports this kind alarm is faulty ,replace

the ODU .

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 6

3. Hard_Bad

Step 1 Remove and insert the alarmed board.

Step 2 Replace the board that reports the alarm, and then check whether the alarm clears.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 7

4. IF_CABLE_OPEN

Step 1 Check whether the connector of the IF cable is loose or whether the connector is not made properly.

Step 2 Check whether the surface of the IF jumper and the IF

cable is damaged, and test the connectivity between the IF jumper and the IF cable.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 8

4. IF_CABLE_OPEN

Step 3 Replace the IF board that reports the alarm. If the alarm

does not disappear, replace the ODU connecting to the board


reports the alarm.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 9

5. BD_STATUS

Step 1 Check whether the logical slot and the physical slot of the

alarmed board are consistent.

Step 2 Remove and insert the alarmed board.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 10

5. BD_STATUS

Step 3 Replace the alarmed board.

Step 4 The slot is faulty. (1) If an idle slot is available, insert the board in the idle slot and

add the board again. Then, the board can work normally.
(2) Contact Huawei engineers to handle the faulty slot.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 11

Thank you