Professional Documents
Culture Documents
Hardware Description
www.huawei.com
Objectives
Page2
Contents
1.
Product Introduction
2.
Cabinet, Sub-rack
3.
Boards
4.
5.
Features
Page3
Product Introduction
Page4
Network Application
4010G
160 10G
iManager T2000
10G/2.5G
OSN 3500 /7500/9500
OSN 1500/2500
OSN 2500/Metro
10G
OSN 7500/9500
OSN 2500/3500
OSN1500/Metro
Long-Haul
Back Bone
10G/2.5G
Core
OSN 3500/7500/9500
OSN 1500/2500
OSN1500/Metro
Page5
Convergenc
e
Access
System Architecture
STM-1
STM-4/16
LU
LU
STM-64
(OSN3500)
LU
order matrix
(VC-4)
Low-order matrix
(VC-12/VC-3)
PDH
Ethernet
TU
TU
SAN/Video
TU
TU
ATM
Timing Unit
External
synchronization
interface
Auxiliary Unit
SCC
Unit
Auxiliary
interface
Page6
Management
interface
capacity
SDH unit
SDH unit
West
STM-1/4/16/64
VC-4-4c/8c /
16c/64c
East
Cross-connect matrix
Large cross-connect
capacity
Multi-granularity
cross-connect
capacity
PDH
Interface
unit
E1/T1/E3/T3/E4
Ethernet
Interface
unit
FE/GE
Other
Interface
unit
ATM/SAN/Video
Page7
Contents
1.
Product Introduction
2.
Cabinet, Sub-rack
3.
Boards
4.
5.
Features
Page8
Cabinet
ETSI 300/600 Cabinet
W(mm)
D(mm)
H(mm)
600
2000
600
2200
300
2600
mounted
OptiX
OSN
1500
H
W
OptiX OSN
2500
OptiX
OSN
3500
2000
2200
2600
Page9
Indicators
Indicator
Power
Critical alarm
Major alarm
Minor alarm
Color
Status
Description
On
Cabinet is powered ON
Off
Cabinet is OFF
On
Critical alarm
Off
No critical alarm
On
Major alarm
Off
No major alarm
On
Minor alarm
Off
No minor alarm
Note:
Indicators do not flash
If alarm indicator is ON, alarm occurs on one or more sub-racks
inside the cabinet
Page10
3
2
OUTPUT
3 4
ON
3
2
OUTPUT
ON
RTN1(+) RTN2(+) NEG1(-) NEG2(-)
OFF
32A
32A
20A
INPUT
20A
2. Power cable
RTN1(+)
OFF
32A
32A
20A
20A
3. Power cable
RTN2(+)
The 1 st & 2nd switches are mainly for the OptiX OSN
Page11
Power Consumption
DC power supply
Equipment
OptiX OSN
1500A
OptiX
OSN
1500B
OptiX
OptiX OSN
OSN 2500
3500
Power
Consumption
(W)
Fuse Capacity
(A)
200
280
400
600
10
10
15
20
Page12
Dimensions
(mm)
Weight (kg)
Page13
SLOT 20
FAN
SLOT 11
SLOT 6
1.25G
2.5G
SLOT 7 1.25G
SLOT 3
2.5G
SLOT 8 1.25G
SLOT 4
2.5G
SLOT 9 1.25G
SLOT 5
2.5G
SLOT 10
l it
sp
SLOT 2
SLOT 1
SLOT 20
FAN
SLOT 11
SLOT 6
1.25G
SLOT 2
1.25G
SLOT 12
1.25G
SLOT 7
1.25G
SLOT 3
1.25G
SLOT 13
1.25G
SLOT 8
1.25G
1.25G
SLOT 4
2.5G
SLOT 9
SLOT 5
2.5G
SLOT 10
Page14
Page15
SLOT 18 PIU
SLOT 15
13 16,17
SLOT 16
SLOT 19 PIU
SLOT 17
SLOT 11
2.5G
SLOT 6 622M
15
SLOT 1 2
2.5G
SLOT 7
622M
17
SLOT 1 3
2.5G
SLOT 8
622M
SLOT 4
2.5G
SLOT 9
622M
SLOT 5
2.5G
SLOT 10
Slot Relation 7
(After split)
8
l it
sp
SLOT 20
FAN
12 14,15
SLOT 14
15
SLOT 18 PIU
SLOT 15
SLOT 16
17
SLOT 19 PIU
SLOT 17
14
12
15
16
13
17
SLOT 20
FAN
SLOT 1 1.25G
SLOT 11 1.25G
SLOT 6
622M
SLOT 2 1.25G
SLOT 12 1.25G
SLOT 7
622M
SLOT 3 1.25G
SLOT 13 1.25G
SLOT 8
622M
622M
SLOT 4
2.5G
SLOT 9
SLOT 5
2.5G
SLOT 10
Page16
Page17
OO O O
T T T T
1 2 3 4 6
6 2 2 2 2 2 2
2 2 . . . . . .
2 2 5 5 5 5 5 5
M M G G G G G G
S
L
O
T
13
S
L
O
T S S S S
L L L L
14
OO O O
T T T T
S 15 16 17 18
1
. A
2 P
5
G
SLOT 23
FAN
SLOT 24
FAN
Slot Relation 20
6
(After split)
12
13
1
2
SLOT 25
PIU
21
7
3
4
1, 2
3, 4
13 17, 18
S
L
O
T
19
S S S S 622
L L L L M
O O O O
T T T T S
1 2 3 4 L
O
T
5
622
M
15 1
6
17 1
12 15, 16
li t
sp
S S S S S S S
L L L L L L L
O O O O O O O
S S S S T T T T T T T
L L L L
5 6 7 8 9 10 11
Slot Relation
S S
L L
O O
T T
20 21
622 1.25
M G
S S
L L
O O
T T
6 7
622 1.25
M G
S S S S
L L L L
O O O O
T T T T
8 9 10 11
S
L
O
T
12
S
L
O
T
13
S
L
O
T S S S S
L L L L
14
O O O O
T T T T
S 15 16 17 18
2 2 2 2 2 1
. . . . . . A
5 5 5 5 5 25 P
G G G G G G
SLOT 23
FAN
Page18
SLOT 24
FAN
SLOT 25
PIU
(mm)
(H)
Weight (kg)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page19
Slot Relation
2 19, 20
S
L
O
T
1
9
S
L
O
T
2
0
S S
L L
O O
T T
2 2
1 2
S
L
O
T
2
3
S
L
O
T
2
4
S
L
O
T
2
5
S
L
O
T
2
6
3 21, 22
4 23, 24
5 25, 26
13 29, 30
14 31, 32
S
L
O
T
2
7
S
L
O
T
2
8
P
I
U
P
I
U
FAN
S
L
O
T
1
S
L
O
T
2
S
L
O
T
3
S
L
O
T
4
S
L
O
T
2
9
S
L
O
T
3
0
S
L
O
T
3
1
S
L
O
T
3
2
S
L
O
T
6
S
L
O
T
7
S
L
O
T
8
S
L
O
T
3
5
S
L
O
T
3
6
S
L
O
T
3
7
S
L
O
T
9
S
L
O
T
10
XCS
XCS
FAN
S S S
L L L
O O O
T T T
11 12 13
15 33, 34
16 35, 36
Fiber Routing
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
S
L
O
T
3
4
A
U
X
FAN
S
L
O
T
5
S
L
O
T
3
3
Page20
S S S S S
L
L L
L L
O O O O O
T T T T T
14 15 16 17 18
S
C
C
S
C
C
Configure 1
Access capacity :
FAN
35G
622 M x 8
2.5 G x 4
10 G x 2
FAN
FAN
S
L
O
T
1
S
L
O
T
2
S
L
O
T
3
S
L
O
T
4
S S S S
L L L L
O O O O
T T T T
5 6 7 8
S
L
O
T
9
S
L
O
T
10
S
L
O
T
11
S
L
O
T
12
S
L
O
T
14
S
L
O
T
15
S
L
O
T
16
6
2
2
M
6
2
2
M
6
2
2
M
6
2
2
M
6 2 2 10
2 . . G
2 5 5
M G G
G
X
C
S
G
X
C
S
10 2 2 6
G . . 2
5 5 2
G G M
6
2
2
M
6
2 S S
2 C C
M C C
Fiber Routing
Page21
S
L
O
T
13
S
L
O
T
17
S
L
O
T
18
Configure 2
Access capacity :
FAN
58.75G
1.25 G x 7
2.5 G x 4
10
Gx4
FAN
FAN
S
L
O
T
1
S
L
O
T
2
S
L
O
T
3
S
L
O
T
4
S S S S
L L L L
O O O O
T T T T
5 6 7 8
S
L
O
T
9
S
L
O
T
10
S
L
O
T
11
S
L
O
T
12
S
L
O
T
15
S
L
O
T
16
S
L
O
T
17
1
.
2
5
G
1
.
2
5
G
1
.
2
5
G
1 2 2 10 10
. . . G G
2 5 5
5 G G
G
E
/
U
X
C
S
E
/
U
X
C
S
10 10 2 2 1
G G . . .
5 5 2
G G 5
G
1
.
2
5
G
1.
25
G S
/ C
S C
C
C
Fiber Routing
Page22
S
L
O
T
13
S
L
O
T
14
S
L
O
T
18
Configure 3
Access capacity :
FAN
155G
5 Gx 7
10 G x 4
20 G x 4
S
L
O
T
1
S
L
O
T
2
S
L
O
T
3
S
L
O
T
4
FAN
FAN
S S S S
L L L L
O O O O
T T T T
5 6 7 8
S
L
O
T
9
S
L
O
T
10
S
L
O
T
11
S
L
O
T
12
5 5 5 5 10 10 20 20
G G G G G G G G
S
X
C
S
S
X
C
S
20 20 10 10 5 5 5G S
G G G G G G S/ C
C C
C
Fiber Routing
Page23
S
L
O
T
13
S
L
O
T
14
S
L
O
T
15
S
L
O
T
16
S
L
O
T
17
S
L
O
T
18
Questions
Page24
Contents
1.
Product Introduction
2.
Cabinet, Sub-rack
3.
Boards
4.
5.
Features
Page25
Contents
3.
Boards
3.1 SDH Unit
3.2 PDH Unit
3.3 Ethernet Unit
3.4 ATM Unit
3.5 MST Unit
3.6 WDM Unit
3.7 Cross-connect and System Control Unit
3.8 Auxiliary Unit
Page26
SDH Unit
Processing
Interface
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page27
Line Unit
16
Digital rate:
- : 1*STM-N signal
64:STM-64
D: 2*STM-N signals
Page28
Board Description
Connecto
Board
Full name
Module available
SF64
SL64
SF16
SLQ16
SL16 (A)
r type
Fixed wavelength output, I-16, S-16.1, L16.1, L-16.2, L-16.2Je, V-16.2Je (with
BA), and U-16.2Je (with BA and PA)
Page29
LC
4 indicators
STAT
ACT
PROG
SRV
SF64
STAT
ACT
PROG
SRV
SF16
STAT
ACT
PROG
SRV
SL16
STAT
ACT
PROG
SRV
SLQ16
S TAT
ACT
P ROG
S RV
SL16A
SFP Module
STAT
ACT
PROG
SRV
CLASS1
LASER
PRODUCT
CLASS 1
LASER
PRODUCT
CLASS 1
LASER
PRODUCT
CLASS 1
LASER
PRODUCT
CLASS 1
LASER
PRODUCT
CLASS 1
LASER
PRODUCT
LC Connector
O U T 1IN 1
O U T I2N 2
OUT
OUT
OUT
IN
IN
IN
IN
OUT
O U T 3IN 3
IN
O U T 4IN 4
Electrostatic
Discharge
OUT
SL64
SF64
SF 16
SL16
SLQ4
Page30
SL16A
CLASS 1
LASER
PRODUCT
Slot available
Slot available
Board
Name
OSN
OSN
OSN
1500A
1500B
2500
SF64
SL64
SF16
SL16(A)
12, 13
11~13
SLQ16
7, 8,
11 ~ 13
OSN 3500
40G
80G
8, 11
7, 8, 11, 12
6 ~ 8,
11 ~ 13
5 ~ 8, 11 ~ 14
200G
1 ~ 8, 11 ~
16
Page31
Board Description
Board
SLQ4
SLD4
SL4
SLT1
SLO1
SLQ1
SL1
Full name
Module available
Connector
type
board
12 x STM-1 processing with optical interface
LC
board
8 x STM-1 processing with optical interface
board
4 x STM-1 processing with optical interface
board
1 x STM-1 processing with optical interface
board
Page32
S LQ4
STAT
ACT
PROG
SRV
STAT
ACT
PROG
SRV
SL4
STAT
ACT
PROG
SRV
CLASS1
CLASS1
LASER
PRODUCT
LASER
PRODUCT
CLASS1
LASER
O U T 2IN 2
SL4
SLT1
CLASS1
LASER
PRODUCT
OUT
IN
O U T 4IN 4
O U T 4I N 4
SLD4
CLASS1
LASER
PRODUCT
O U T 3I N 3
O U T 3I N 3
SLQ4
CLASS1
LASER
PRODUCT
O U T 2IN 2
O U T 1IN 1
O U T I2N 2
CLASS 1
LASER
PRODUCT
SL1
STAT
ACT
PROG
SRV
O U T 1IN 1
O U T 1I N 1
IN
STAT
ACT
PROG
SRV
OUT
SLQ1
SLO1
STA T
ACT
PR OG
SR V
PRODUCT
SLT1
STAT
ACT
PROG
SRV
CLAS S1
LASE R
PRODUCT
SLO1
SLQ1
Page33
SL1
OSN
OSN
1500A
1500B
OSN 3500
OSN 2500
6 ~ 8,
SLQ4
SLT1
80G
5 ~ 8, 11 ~ 14
11 ~
SLD4
SL4
40G
13
12, 13
11~13
5 ~ 8,
11 ~ 13
1 ~ 8,
SLO1
11 ~
SLQ1
16
1 ~ 8, 11 ~ 17
SL1
Page34
200G
Board
SEP1
Full name
2 x STM-1 processing with electrical
interface board
Board
Full name
SLH1
SEP
Board
Full name
OU08
EU08
EU04
Board
TSB4
TSB8
board
4 x electrical signal access
Full name
board
Tributary Switch Board for 4
Signal
processing with
electrical
interface board
Connector type
SMB
Signal processing
Connector (Interface)
type
LC/SC (I-1 and S-1.1)
Interface
SMB
SMB
TPS
signals
Tributary Switch Board for 8
signals
Page35
SEP1
SEP
Page36
OUT1 IN1
OUT2 IN2
OUT3 IN3
OUT4 IN4
OUT5 IN5
OUT6 IN6
OUT7 IN7
OUT1IN1OUT2IN2OUT3IN3OUT4IN4OUT5IN5OUT6IN6OUT7IN7OUT8IN8
OUT8 IN8
Page37
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
TSB8
OU08
OU08
EU04
EU08
CLASS 1
LASER
PRODUCT
C
o
n
n
e
c
t
o
r
SEP1
SLH1
SFP Module
OUT1IN1 OUT2 IN2 OUT3IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 O UT8IN8
S
M
B
TSB8
OU08
OU08
EU04
EU08
SC Connector
STAT
ACT
PROG
SRV
STAT
ACT
PROG
SRV
SEP1
SLH1
Slot available
Board
Name
SEP1
OSN
OSN
OSN
1500A
1500B
2500
12,13
11~13
5 ~ 8,
11 ~ 13
SLH1
SEP
OU08
EU08
40G
80G
OSN 7500
200G
1 ~ 6, 13 ~ 16
2 ~ 5,
13 ~
16
12, 13
6 ~ 7,
12 ~ 13
2 ~ 5, 13 ~ 16
14, 16
1 ~ 4,
15 ~ 18
19, 21,
19 ~
23, 25,
26, 29
29, 31,
~ 36
33, 35
19, 21, 23, 25, 29, 31,
33, 35
14
1,17
19,35
240G
360G
1 ~ 3, 17, 18
EU04
TSB4
TSB8
Slot available
OSN 3500
2, 3, 17, 18
19 ~ 22, 35 ~
38
37,38
Page38
Boards Description
Board
R1SLD4
R1SL4
R1SLQ1
R1SL1
Full name
Connector
Module available
type
4.2
LC
1.2
Page39
R1SLD4
R1SL4
STAT
ACT
PROG
SRV
STAT
ACT
PROG
SRV
R1SLQ1
O U TIN
R1SL4
R1SL1
STAT
ACT
PROG
SRV
O U T IN
O U T 1IN 1 O U T 2IN 2
R1SLD4
R1SLQ1
STAT
ACT
PROG
SRV
R1SL1
Page40
Slot available
Slot available
Board
Name
OSN
OSN
OSN
1500A
1500B
2500
1 ~ 3, 11
~ 13
7, 21
R1SLD4
R1SL4
R1SLQ1
R1SL1
2, 3, 6 ~
9, 12, 13
1 ~ 3, 6
~ 9, 11 ~
13
OSN 3500
40G
80G
200G
5 ~ 7,19
~ 21
R1- boards are used in the small slots in OptiX OSN 1500 or when slots are
segmented in OptiX OSN 1500/2500.
Page41
Indicator
Indicator
STAT
Board
Status
ACT
Board
Activation
Status
Color
Description
On, green
On, red
Off
On, green
Board is activated/configured.
Off
Page42
Slot available
Indicat
or
PROG
Board
Software
Status
Color
Description
On, green
On, red
Off
No power supply.
On, green
SRV
Critical or major alarm occurs to service.
On, red
Service
Alarm 2006
Minor
or remote alarm occurs to service.
Copyright
reserved.
On,Huawei
yellowTechnologies Co., Ltd. All rights
Page43
Functions of SL16
Collect Alarm
and
performance
C
o SC
t
d
Sen
TR
U-P
A
and ssing
H
O
ce
pro
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page44
Send to Cross-connect
unit
STM-16
16
X
VC
4
Features of SL16
Page45
I-16
(01)
S16.1
(02)
L-16.1
(03)
L-16.2
(04)
L16.2Je
(02)
V-16.2Je
(BA)
(03)
U-16.2Je
(BA+PA) (04)
Wavelength (nm)
1310
1310
1310
1550
1550
1550
1550.12
Distance (km)
02
2 15
15 40
40 80
80
100
80 140
140 170
-10~3
-5~0
-2~3
-2~3
5~7
14
17
-18
-18
-27
-28
-28
-28
-34
-3
-9
-9
-9
-9
-10
(Board characteristic
#)
Receiver sensitivity
(dBm)
Receiver overload
(dBm)
Page46
unit
Alarm
level
Critical
Major
Colo
r
Alarm
name
R_LOS
MS_AIS
AU_AIS
POWER_
ABNORMAL
MS_RDI
Minor
HP_RDI
LOOP_ALM
Alarm reason
Receiver can not receive STM-N signal normally.
Critical alarm e.g. R_LOS happens.
Critical alarm e.g. R_LOS happens.
Wrong service configuration
Faulty SDH board
Power module of the line board fails.
Opposite station receives the R_LOS, R_LOF or MS_AIS
signal
Faulty receiver at the opposite node or transmitter at
the local node
Opposite node receives such alarms as AU_AIS and
AU_LOP.
Faulty receiver at the opposite node or transmitter at
the local node
Software inloop or outloop is being performed.
Page47
Performance meaning
RSBBE
MSBBE
MSFEBBE
HPBBE
HPFEBBE
RPLCUR
RPLMAX
RPLMIN
TPLCUR
TPLMAX
TPLMIN
Page48
PDH Unit
Board
Name
Description
Interface board
SPQ4
Processes 4 x E4/STM-1
MU04
PD3
Processes 6 x E3/T3
D34S
PL3
Processes 3 x E3/T3
C34S
PL3A
Processes 3 x E3/T3
PQM
Processes 63 x E1/T1
PQ1
Processes 63 x E1
PD1
Processes 32 x E1/T1
L75S,L12S,D75S,D12S,D12B
PL1
Processes 16 x E1/T1
PD1 and PL1 are used in the small slot in OptiX OSN 1500/2500.
PD1 cooperates with L75S/L12S in OptiX OSN 1500A, and cooperates with
D75S/D12S in OptiX OSN 2500 or OptiX OSN 1500B.
Page49
Slot available
Board
Name
OSN
OSN
OSN
1500A
1500B
2500
SPQ4
PD3
C34S
80G
200G
6, 7,
12, 13
2 ~ 5, 13 ~ 16
12, 13
11~13
5 ~ 8,
11 ~
13
1 ~ 8, 11 ~
16
14, 16
1, 3,
15, 17
MU04
D34S
40G
12, 13
PL3
PL3A
OSN 3500
1 ~ 8, 11 ~ 17
PL3A is a processing board with cables led out from the front panel. .
Page50
SPQ4/MU04
SPQ4
M U 04
STAT
ACT
PROG
SRV
SMB connector
Indicators
O U T 1 IN 1 O U T 2 IN 2 O U T 3IN 3 O U T 4 IN 4
SPQ4
M U 04
Page51
PL3
STAT
ACT
PROG
SRV
D34S
P L3A
C34S
STAT
ACT
PROG
SRV
SMB connector
Indicators
PL3A
D34S
O U T 1I N 1 O U T 2I N 2 O U T 3I N 3
PL3
O U T 1I N 1 O U T 2I N 2 O U T 3I N 3 O U T 4I N 4 O U T 5I N 5 O U T 6I N 6
O U T 1I N 1 O U T 2I N 2 O U T 3I N 3
PD3
C34S
Page52
Slot available
Slot available
Board
Name
PQM
PQ1
OSN 3500
OSN
OSN
1500A
1500B
11 ~
13
14 ~ 17
1 ~ 5, 13 ~ 16
14 ~
17
1 ~ 4, 15 ~ 18
19 ~ 26, 29 ~ 36
OSN 2500
40G
80G
D75S
D12S
D12B
Page53
200G
Slot available
Board
Name
OSN
OSN
OSN
1500A
1500B
2500
PD1
2, 12
1 ~ 3, 6
~ 8, 11
~ 13
PL1
6~9
6~9
6~7
L75S
L12S
5 ~ 7, 19
~ 21
OSN 3500
40G
80G
200G
PL1 is a processing board with cables let out from the front panel.
PD1/PL1 can be used in the small slot or used when slots are segmented in OptiX OSN
1500/2500.
Page54
DB44
D 75 S
PQM
D 12 S
D12B
STAT
ACT
PROG
SRV
18
18
18
2mmHM
L12S
L75S
1 72 4
1 72 4
1 72 4
D12S
D12B
Page55
1-16
D75S
1-1 6
2 53 2
2 53 2
2 53 2
PQM
91 6
PL1
STAT
ACT
PROG
SRV
1-16
PQ1
91 6
91 6
PD1
STAT
ACT
PROG
SRV
Functions of PQ1
C
o SC
t
d
Sen
1 X VC4
63
X
E1
E1
and
H
O
LP
PTR
U
T
s s in
e
c
pro
Page56
Send to Cross-connect
unit
Collect Alarm
and
performance
Features of PQ1
Page57
Colo
level
Alarm name
ALM_SUBCARD_ABN
Major
T_ALOS
Alarm reason
The interface board and the processing
board are mismatched
No E1 service is accessed
Critical alarm e.g. R-LOS happens
TU_AIS
Minor
LP_RDI
LP_REI
Page58
Performance meaning
LPBBE
LPFEBBE
LPES
LPFEES
TUPJCHIGH
TUPJCLOW
Page59
Ethernet Unit
Number of ports on the front panel
Ethernet
Note:
If there is no port on the board, then the board must work with an interface board.
ETF8/EFF8 is the interface board. ETF8 accesses 8FE twisted pair signal, and
EFF8 accesses 8FE optical signal
Page60
Ethernet Unit
Boards Description
Board
Full name
Interface type
Connector
EGS4
4 x GE with L2 switching
processing with interface
board
1000BASE-SX/LX/ZX
LC
EGS2
2 x GE with L2 switching
processing with interface
board
1000BASE-SX/LX/ZX
LC
EGT2
2 x GE transparent
transmission processing with
interface board
1000BASE-SX/LX/ZX
LC
EMS4
4 GE + 16 x FE with L2
switching processing with
interface board
1000BASE-SX/LX/ZX,
100Base-FX (From interface
board)
RJ-45, LC
Page61
EGS4
STAT
ACT
PROG
SRV
EMS4
EG T 2
STAT
STAT
ACT
PROG
SRV
LINK1
ACT1
LINK2
ACT2
STAT
ACT
PROG
SRV
LINK1
ACT1
LINK2
ACT2
ACT
PROG
SRV
CLASS 1
CLASS 1
LASER
PRODUCT
LASER
PRODUCT
CLASS 1
LASER
PRODUCT
CLASS 1
LASER
PRODUCT
O U T 2IN 2
O U T 2IN 2
O U T 1IN 1
O U T 1IN 1
O U T 2IN 2
O U T 2IN 2
O U T 1IN 1
O U T 1IN 1
O U T 3IN 3
O U T 3IN 3
O U T 4IN 4
O U T 4IN 4
LINK
LINK
ACT
CLASS 1
LASER
PRODUCT
Indicator
LINK
EG S2
EG T 2
Status
EM S4
Description
On
Link is established
Off
Flashin
ACT
ACT
EGS4
Color
g
Off
Page62
Data exchanged
No data being
exchanged
Full name
EGR 2
EMR0
STAT
ACT
PROG
SRV
LINK1
ACT1
LINK2
ACT2
EGR2
EMR0
STAT
ACT
PROG
SRV
LINK
ACT
CLASS 1
O U T 2IN 2
O U T 1IN 1
Function
LASER
PRODUCT
O U T 1IN 1
CLASS 1
LASER
PRODUCT
EVPL/EVPLAN Service
FE1
QoS
FE2
FE3
GE PORT
SFP Module
FE PORT
RJ 45 connector
Page63
FE4
EGR2
EMR0
Slot available
Slot available
Board
Name
EGS4
EGS2
EGT2
EMS4
OSN
OSN
OSN
1500A
1500B
2500
40G
80G
200G
12, 13
EGR2
12, 13
EMR0
OSN 3500
11 ~ 13
5 ~ 8, 11
~ 13
(11)12,
13
(11)12,
13
1 ~ 8, 11 ~ 16
1 ~ 6, 13 ~ 16
6, 7, 12,
13
1 ~ 8, 11 ~ 16
5 ~ 8, 11
~ 13
1 ~ 6, 13 ~ 16
1 ~ 4, 15
~16
Page64
Boards Description
Board
Full name
Interface type
Connector
EFS4
4 x FE with L2 switching
processing with interface board
10Base-T/ 100Base-TX
RJ-45
EFS0
8 x FE with L2 switching
processing board
EFT8
8 (16) x FE transparent
transmission processing with
interface board
10Base-T/ 100Base-TX
RJ-45
10Base-T/ 100Base-TX
RJ-45
10Base-T/ 100Base-TX
RJ-45
100Mbit/s-FX
LC
ETF8
ETS8
EFF8
Page65
EFS0
EFT 8
STAT
ACT
PROG
SRV
STAT
ACT
PROG
SRV
RJ 45 connector
FE1
FE2
FE1
FE3
FE4
EFT 4
FE2
STAT
ACT
PROG
SRV
FE5
FE6
FE3
FE7
FE1
FE8
FE2
FE3
FE4
FE4
EFS4
EFS0
EFT8
Page66
EFF 8
ETF8
1
2
3
4
5
6
7
8
FE PORT
RJ 45
Connector
LINK ACT
FE2 FE3
FE4
FE1 FE2
FE6 FE7
FE8
FE5
FE3 FE4
FE1
CLASS 1
LASER
PRODUCT
Board
Name
Interface Board
EFT8
ETF8,EFF8
EFS0
ETF8,EFF8,EFS8
EMS4
EMR0
ETF8,EFF8
FE8
ETS8
EFF8
ET F8
Page67
Boards Description
Slot available
Board
Name
EFS4
OSN
OSN
1500A
1500B
12, 13
11 ~
13
EFS0
OSN 3500
OSN 2500
5 ~ 8, 11 ~
13
6, 7, 12, 13
7, 12, 13
(5 ~ 8, 11
~ 13)
40G
80G
200G
1 ~ 8, 11 ~ 16 (17)
2 ~ 5, 13 ~ 16
12 ~
13
EFT4
2, 3, 6,
9, 12,
13
1 ~ 3,
6 ~ 9,
12, 13
5 ~ 7, 19 ~
21
ETF8
ETS8
EFF8
14 ~
16
1, 3, 15, 17
EFT8
1 ~ 6, 13 ~ 16
Page68
Function of EFS4
Collect Alarm
and
performance
4
X
FE
GFP
NVC12/VC3
VC-12Xv(x63), VC3-Xv(x12)
8 X VC4
Page69
Send to Cross-connect
unit
FE
SCC
o
t
d
Sen
Features of EFS4
Supports MPLS
Supports LCAS
Page70
Major
Color
Alarm name
HARD_BAD
ETH_LOS
TU_AIS_VC3
PROTOCOL_MM
LP_RDI_VC3
Minor
LCAS_BAND_
DECREASED
Alarm reason
Faulty board hardware
Interrupted Ethernet link
Interrupted contiguous VC3-xc
Mismatched encapsulation protocol
TU_AIS_VC3 happens in the opposite node
VC-Trunk bandwidth decreases
Page71
Performance
name
Performance meaning
DropOv
DropUd
RxBadOctOv
RxBadOctUd
TxBadOctOv
TxBadOctUd
ColOv
ColUd
Page72
ATM Unit
Boards Description
Board
ADL4
ADQ1
Full name
Interface type
interface board
4.2
interface board
1.2, L-1.1
Connecto
r type
LC
IDL4
IDQ1
interface board
4.2
interface board
1.2, L-1.1
Page73
ADQ1
STAT
ACT
PROG
SRV
CLASS 1
I DQ1
I DL4
STAT
ACT
PROG
SRV
STAT
ACT
PROG
SRV
CLASS 1
STAT
ACT
PROG
SRV
CLASS 1
CLASS 1
LASER
LASER
LASER
LASER
PRODUCT
PRODUCT
PRODUCT
PRODUCT
O U TI N1 1
O U T IN
1 1
O U T IN
1 1
O U T IN
1 1
O U TI 2N 2
O U T I2N 2
CLASS 1
LASER
PRODUCT
O U TI 3N 3
O U T I3N 3
ADQ 1
O U T I 4N 4
O U T 4IN 4
ADL4
IDL4
I DQ1
Page74
S
F
P
C
O
N
N
E
C
T
O
R
Slot available
Slot available
Board
Name
OSN
OSN
OSN
1500A
1500B
2500
ADL4
ADQ1
12, 13
IDL4
IDQ1
(11),
12, 13
OSN 3500
40G
80G
200G
6 ~ 8,
11 ~ 13
1 ~ 8, 11 ~ 17
1 ~ 8,
11 ~ 16
1 ~ 8,11 ~ 17
7, 8, 1113
Page75
Function of ADQ1
Collect Alarm
and
performance
4
X
ATM
Send to Cross-connect
unit
ATM
SCC
o
t
d
Sen
Mappe
r
VC-12, VC-4,
VC-4-Xv
8
X
VC4
Page76
Features of ADQ1
Supports QoS
Page77
Alarm
level
Color
Alarm
name
VPAIS
Alarm reason
More critical alarms e.g. R_LOS happens.
Critica
VCAIS
Major
VPRDI
VCRDI
LCD
Page78
unit
Performance name
Performance meaning
VC3BBE
VC3ES
VC3FEBBE
VC3FEES
ATM_INGCELL
ATM_EGCELL
ATM_CORRECTED_HCSERR
ATM_UNCORRECTED_HCSER
R
ATM_RECV_CELL
ATM_RECV_IDLECELL
ATM_TRAN_CELL
Page79
MST Unit
Board description
Board Name
Description
4 x multi-service transparent
MST4
Slot available
Slot available
Board
Name
MST4
OSN
OSN
1500A
1500B
12, 13
11 ~ 13
OSN 2500
OSN 3500
5 ~ 8, 11 ~
13
1 ~ 8, 11 ~
16 (17)
Page80
MST Unit
Service Types
Service type
Rate
Remarks
GE
1000 Mbit/s
Data service
FC50
531.25 Mbit/s
FC100/FICON
1062.5 Mbit/s
SAN service
FC200
2125 Mbit/s
SAN service
ESCON
200 Mbit/s
SAN service
DVB-ASI
270 Mbit/s
Video service
Page81
M ST 4
STAT
ACT
PROG
SRV
O U T 1IN 1
O U T 2IN 2
O U T 3IN 3
O U T 4IN 4
M ST 4
S
F
P
C
O
N
N
E
C
T
O
R
side
SFP Modules
Services
SDH side
Client side
FC100
3000km
40km
FC200
1500km
20km
Page82
Function
Collect Alarm
and
performance
Send to Cross-connect
unit
Multi-Services
SAN
C
o SC
t
d
Sen
GFP-T
VC-4-4c/8c/16c
16
X
VC4
Page83
Timing Unit
SCC Unit
Line Unit
Page84
Cross-Connect Unit
SDH unit
PDH unit
Data unit
Collect Alarm
to S
d
n
Se
High-order cross-connect
matrix
Low-order cross-connect
matrix
MultiGranularity:
VC12/VC3/VC4/V
C-4-xc
Page85
CC
CX L 4
CXL1
STAT
ACTX
ACTC
PROG
SRVX
SRVL
SYNC
ALMC
STAT
ACTX
ACTC
PROG
SRVX
SRVL
SYNC
ALMC
STAT
ACTX
ACTC
PROG
SRVX
SRVL
SYNC
ALMC
CLASS 1
LASER
PRODUCT
CLASS 1
LASER
PRODUCT
CLASS 1
LASER
PRODUCT
Indicato
r
Color
O U TIN
O U TIN
O U TIN
RESET
RESET
RESET
ALM CUT
ALM CUT
ALM CUT
Description
ACTX
status
Cross-connect unit is in standby
status
CX L 1 6
CX L 4
CX L 1
Logical unit
GXCL (5G)
EXCL (20G)
Page86
Page87
OSN 3500
Cross-connect
Max
High-order
Low-order
For Extension
and timing
access
cross-connect
cross-connect
sub-rack HO
board
capacity
capacity
capacity
XC capacity
GXCS
35G
35G
5G
EXCS
58.75G
75G
5G
UXCSA
58.75G
60G
20G
UXCSB
60G
60G
20G
1.25G
SXCSA
155G
180G
20G
SXCSB
156.25G
180G
20G
1.25G
XCE
1.25G
1.25G
Page88
EXCSA
UXCSA
STAT
ACT
PROG
SRV
SYNC
STAT
ACT
PROG
SRV
SYNC
STAT
ACT
PROG
SRV
SYNC
GXCSA
EXCSA
UXCSA
UXCSB
STAT
ACT
PROG
SRV
SYNC
XCE
STAT
ACT
PROG
SRV
SYNC
EXA
EXA
EXB
EXB
UXCSB
XCE
SXCSA
STAT
ACT
PROG
SRV
SYNC
SXCSB
STAT
ACT
PROG
SRV
SYNC
EXA
EXB
SXCSA
SXCSB
Page89
XCE
STAT
ACT
PROG
SRV
SYNC
STAT
ACT
PROG
SRV
SYNC
EXA
EXB
UXCSB
DB26 Connector:
To connect the
main sub-rack and
the extension subrack together.
UXCSB/SXCSB
EXA
EXA
EXB
EXB
EXA
EXA
EXB
EXB
EXA
EXB
XCE
XCE
Page90
Cross-Connect Unit
10G line unit
Crossconnect
PDH unit
Crossconnect
Standby
PDH unit
Active
Ethernet unit
Ethernet unit
Page91
Features
Active/standby Restoration
Page92
Indicator
Color
Description
Clock works in Normal mode
SYNC
Clock works in hold-over or free-run mode
Page93
Indicato
Colo
ACT
SYNC
Description
ON Board is active/OFF Board is standby
Clock works in Normal mode
Clock works in hold-over or free-run mode
Page94
Timing Unit
Features
Process traced clock signal from Line, Tributary and external clock
working modes
Page95
unit
Alarm
level
Color
Alarm name
BUS_ERR
Major
Minor
APS_INDI
TEMP_OVER
W_OFFLINE
EXT_SYNC_LOS
CLOCK_ENTER_NO
_TRACE_MODE
APS_FAIL
Warning
Alarm reason
SWITCH_DISABLE
OTH_BD_STATUS
Page96
SDH unit
Commands
PDH unit
Other unit
Cross-connect unit
NMS
DCC
Other NE
Page97
CLASS 1
LASER
PRODUCT
Reset board
RESET
ALM CUT
Alarm cut
switch
(short and
long press)
CXL1
Page98
GSCC
Reset
STAT
ACT
PROG
SRV
PWRA
PWRB
PWRC
ALMC
Color
Description
The 48 V power supply A is normal.
PWRA
RESET
PWRB
ALM CUT
PWRC
RESET
Alarm cut
SCC
ALMC
ALM CUT
GSCC
Page99
Functions
Extended ECC
Page100
NMS
Ring A
Ring B
Ethernet
port
L< 50m
Page101
Ethernet
port
Issued data
MDB
Automatically saves the current
data in dynamic RAM.
If power fails, the data in MDB will
be lost.
MDB
DRDB
Automatically saves the
successfully verified data.
If power fails, the data in
DRDB will be lost.
FDB0, FDB1
Manually or periodically
saves the data. Enduringly
saves data and does not
need battery.
verify
Fail
NE in installing
status
Success
DRDB
Boards in
running status
Save manually or
periodically every 30 mins
FDB0
FDB1
Page102
Alarm
Colo
level
Critical
Alarm name
Alarm reason
NESTATE_INSTALL
MSSW_DIFFERENT
WRG_BD_TYPE
Major
NESF_LOST
POWER_ABNORMA
POWER_FAIL
Page103
Auxiliary Unit
Board Description
Board
Function
Remark
AUX
PIU
EOW
Orderwire Board
SAP
SEI
UPM
External
AMU
BA2
BPA
Pre-amplifier Board
COA
External
DCU
FAN/FANA
Fan unit
Page104
AUX
ETH
COM
CLK
ALM
OAM/F&f
AMU
STA T
PR OG
AM U
PHONE
S1
S2
LAMP1
LAMP2
Page105
Q
1SAP
STAT
PROG
PWRA
PWRB
PWRC
F&f: LCT
PHONE: Orderwire
CLK1/2: 120 Ext clock input/output 1/2
V1/2: NNI Audio/Signaling
ALMO1 ALMO2
LAMP
1
LAMP
2
OA
M
F1
F&
f
PHONE
CLK1
CLK2
CO
M
ALMI1
ALMI2
S1
S2
S3
S4
V1
V2
E
TH
Q
1SAP
Page106
CLK2
ETH
COM
EXT
ALMP1
ALMP2
ALMO1
ALMO2
ALMI1
ALMI2
ALMI3
ALMI4
CLK1
REV
F&f
F1
PHONE
V1
V2
OAM
S1
S2
S3
S4
CLKO1 CLKO2
NIAUX
STAT
NIAUX
CLKI1
Page107
P IUA
NEG(-)
RTN(+)
Switch
CLK IN
PWR
NEG(-)
Interfac
e
75 synchronization
input/output (SMB) interface
PWR
48 V power access
interface
PWS
50 W power output
interface, supplying power
for COA or HUB
Description
CLK
IN/OUT
R 1 P IU
POW ER
PWS
R 1 P IU
POWER
P IUA
Indicat
or
Power
indicator
Status
Description
On, green
Power input is
normal
Off
No power input or
power failure
Page108
NIPIU
PWS
RTN(+)
Used in OSN
3500
Inserted in slot
27 and 28
PWR
NEG(-)
PWR
PS1
PS2
Interface
Description
PWS
NIPI U
PWR
Page109
Functions
Lightning protection
Page110
The EOW board is the orderwire board used in OptiX OSN 1500,
which is inserted in slot 9 of the sub-rack.
EOW
EOW
STAT
PROG
PHONE
S1
S2
S3
S4
Page111
Functions of UPM
Height 1U
Page112
! CAUTION
BAT-
BAT+
48V+
48VLOAD1
LOAD2
5
AC100~240
6
RUN
ALM Vout
ALM
ALM Vout
RS232
1: AC input
4: Battery input
3: Communication interface
Page113
Connecto
r
Description
BA2
LC
BPA
Pre-amplifier Board
LC
COA
LC
Slot available
Board
COA
BA2
BPA
OSN
OSN
OSN
1500A
1500B
2500
OSN 3500
External
12, 13
11 ~ 13
5 ~ 8, 11
~ 13
1 ~ 8, 11
~ 16 (17)
Page114
Tx
Rx
BA
Page115
O U T 1IN 1
1/ 2 BA
modules
LC connector
O U T 2IN 2
Specifications
IN1/2 (dBm)
CLASS 1
LASER
PRODUCT
6 ~ +3
BA2
Output 1
Output 2
(dbm)
(dbm)
+13 ~ +15
+15 ~ +17
+13 ~ +15
+13 ~ +15
+15 ~ +17
+15 ~ +17
+13 ~ +15
+15 ~ +17
Page116
Function
Used on TX side
ALS function
Page117
Gain
22 dB
Tx
Rx
PA
Page118
P O U T P IN
Port 2:
PA module
LC connector
Specifications
B O U T B IN
Port 1:
BA module
LC connector
BIN (dBm)
BOUT (dBm)
-6 ~ +3
-
PIN
POUT
(dBm)
(dBm)
+13 ~ +15
-10 ~ -37
+11 ~ -16
+15 ~ +17
CLASS 1
LASER
PRODUCT
BPA
Page119
Function
1-channel pre-amplification
ALS function
Page120
1. ID DIP switch
5. RS232-2
9. OUT output optical
10
2. Running
3. Alarm
indicator
indicator
6. MONITOR-1
7. MONITOR-2
Copyright
2006 Huawei Technologies Co., Ltd. All rights reserved.
port
11
4. RS232-1
8. IN input optical
port
Page121
External installation
Types
61COA
62COA
Page122
Amplifier Unit
Critical
Color
Alarm name
Alarm reason
IN_PWR_FAIL
No input signal
IN_PWR_HIGH
IN_PWR_LOW
OUT_PWR_ABN
PUM_COOL_ALARM
Page123
Amplifier Unit
Performance name
Performance meaning
EDRPLAVG
EDRPLMAX
EDRPLMIN
EDTMPCUR
EDTMPMAX
EDTMPMIN
EDTPLCUR
EDTPLMAX
EDTPLMIN
Page124
Board
DCU
Description
Connector
Dispersion compensation
board
LC
1/2 DCM
LC connector
O U TI N1 1
O U T I2N 2
Slot available
Board
DCU
OSN
OSN
OSN
OSN
OSN
1500A
1500B
2500
3500
7500
1 ~ 8, 11
~ 17
1-8, 11-18,
26-31
DC U
Page125
Tx
BA
DCU
DCU
PA
Insertion loss 7 dB
Used for 10G signals
Inserted in slots 1 ~ 8, 11 ~ 16
Works with BA and PA
Page126
Rx
Page127
Function
Color
Description
Fan operates normally.
STAT
Alarm level
Major
Color
Alarm name
FAN_FAIL
Alarm reason
Faulty fan
Fan is power off
Page128
Questions
Page129
Contents
1.
Product Introduction
2.
Cabinet, Sub-rack
3.
Boards
4.
5.
Features
Page130
Contents
4. Common network elements
4.1 Terminal multiplexer (TM)
4.2 Add and drop multiplexer (ADM)
4.3 Multi-add and drop multiplexer (MADM)
4.4 Regenerator (REG)
Page131
Terminal multiplexer
TM
Page132
TM functions
Add and drop tributary signals
Page133
TM configuration
Tributary unit
16 x E1s
Line unit
STM-16
PL3A
Slot 20 CXL16
Tributary unit
3 x E3s
FAN
Slot 1 PIU
CXL16
3 x E3s
32 x E1s
PIU
Line unit
STM-16
Slot 11PL1
Slot 6
Slot 12
Slot 7
Slot 13
Slot 8
Slot 4
EOW
Slot 9
Slot 5
AUX
Slot 10
Slot 1 PIU
Slot 11 L75S
Slot 6
Slot 2PD1
Slot 12 L75S
Slot 7
PL3A
Slot 13
Slot 8
CXL16
Slot 4EOW
Slot 9
Slot 5 AUX
Slot 10
PIU
FAN
Slot 20 CXL16
Page134
TM configuration
Tributary unit
63 x E1s
3 x E3s
Line unit
D75S
D75S
C34S
STM-16
Slot14
PIU
Slot15
Slot16
PIU
Slot 17
Slot19
Slot 11
Slot 6
PQ1
Slot 12
Slot 7
PL3
Slot 13
Slot8
CXL16
Slot 4EOW
Slot 9
CXL16
Slot 5 AUX
Slot 10
Slot 20
FAN
Slot18
Page135
TM configuration
Tributary unit
63 x E1s
4 x E3s
D
7
5
S
D
7
5
S
D
3
4
S
S
l
o
t
1
S
l
o
t
2
S
l
o
t
3
P
Q
1
P
D
3
S
l
o
t
6
S
l
o
t
7
Line unit
C
X
L
1
6
C
X
L
1
6
S
l
o
t
9
S
l
o
t
1
0
S
A
P
STM-16
S
l
o
t
4
S
l
o
t
5
S
l
o
t
8
S
l
o
t
1
1
S
l
o
t
1
2
S
l
o
t
1
3
S
l
o
t
1
4
S
l
o
t
1
5
S
l
o
t
1
6
S
l
o
t
1
7
S
l
o
t
1
8
SLOT 23
FAN
SLOT 24
FAN
Page136
SLOT 25
PIU
D
3
4
S
TM configuration
Tributary unit
126 x E1s
Line unit
STM-64
S
l
o
t
1
9
S
l
o
t
2
0
6 x E3s
S
l
o
t
2
1
D
7
5
S
S
l
o
t
2
2
S
l
o
t
2
3
D
7
5
S
D
7
5
S
S
l
o
t
2
4
S
l
o
t
2
5
D
7
5
S
S
l
o
t
2
6
A
U
X
P
I
U
P
I
U
FAN
S
l
o
t
1
S
l
o
t
2
S S S
l l l
o o o
t t t
3 4 5
S
l
o
t
3
0
S
l
o
t
3
1
S
l
o
t
3
2
S
l
o
t
3
3
S
l
o
t
3
4
FAN
P P P
D Q Q
3 1 1
2 x STM-1e
S
l
o
t
2
9
S
l
o
t
6
S
l
o
t
7
S
L
6
4
G
X
C
S
G
X
C
S
S
l
o
t
8
S
l
o
t
9
S
l
o
t
1
0
S
l
o
t
3
6
S
l
o
t
3
7
FAN
S
E
P
1
S
l
o
t
1
2
Fiber Routing
Page137
S
l
o
t
3
5
S
l
o
t
1
2
S
l
o
t
1
3
S
l
o
t
1
4
S
l
o
t
1
5
G G
S S
C C
C C
S
l
o
t
1
6
S
l
o
t
1
7
S
l
o
t
1
8
ADM
Page138
ADM functions
Add and drop tributary signals
Page139
ADM configuration
Tributary unit
16 x E1s
Line unit
Slot 1 PIU
PL3A
Slot 11PL1
Slot 7
Slot 13
Slot 8
Slot 20 CXL16
Line unit
STM-16
Slot 6
Slot 12
CXL16
Tributary unit
3 x E3s
FAN
STM-16
3 x E3s
32 x E1s
PIU
Slot 4 EOW
Slot 9
Slot 5 AUX
Slot 10
Slot 1 PIU
Slot 11 L75S
Slot 6
Slot 2PD1
Slot 12 L75S
Slot 7
PL3A
Slot 13
Slot 8
CXL16
Slot 4EOW
Slot 9
Slot 5 AUX
Slot 10
PIU
FAN
Slot 20 CXL16
Page140
ADM configuration
Tributary unit
63 x E1s
3 x E3s
Line unit
D75S
D75S
C34S
STM-16
Slot14
PIU
Slot15
Slot16
PIU
Slot 17
Slot19
Slot 11
Slot 6
PQ1
Slot 12
Slot 7
PL3
Slot 13
Slot8
CXL16
Slot 4EOW
Slot 9
CXL16
Slot 5AUX
Slot 10
Slot 20
FAN
Slot18
Page141
ADM configuration
Tributary unit
63 x E1s
4 x E3s
D
7
5
S
D
7
5
S
D
3
4
S
S
l
o
t
1
S
l
o
t
2
S
l
o
t
3
P
Q
1
P
D
3
S
l
o
t
6
S
l
o
t
7
Line unit
C
X
L
1
6
C
X
L
1
6
S
l
o
t
9
S
l
o
t
1
0
S
A
P
STM-16
S
l
o
t
4
S
l
o
t
5
S
l
o
t
8
S
l
o
t
1
1
S
l
o
t
1
2
S
l
o
t
1
3
S
l
o
t
1
4
S
l
o
t
1
5
S
l
o
t
1
6
S
l
o
t
1
7
S
l
o
t
1
8
SLOT 23
FAN
SLOT 24
FAN
Page142
SLOT 25
PIU
D
3
4
S
ADM configuration
Tributary unit
126 x E1s
Line unit
STM-64
S
l
o
t
1
9
S
l
o
t
2
0
6 x E3s
S
l
o
t
2
1
D
7
5
S
S
l
o
t
2
2
S
l
o
t
2
3
D
7
5
S
D
7
5
S
S
l
o
t
2
4
S
l
o
t
2
5
D
7
5
S
S
l
o
t
2
6
A
U
X
P
I
U
P
I
U
FAN
S
l
o
t
1
S
l
o
t
2
S S S
l l l
o o o
t t t
3 4 5
S
l
o
t
3
0
S
l
o
t
3
1
S
l
o
t
3
2
S
l
o
t
3
3
S
l
o
t
3
4
FAN
P P P
D Q Q
3 1 1
2 x STM-1e
S
l
o
t
2
9
S
l
o
t
6
S
l
o
t
7
S
l
o
t
3
6
S
l
o
t
3
7
FAN
S
L
6
4
G
X
C
S
G
X
C
S
S
L
6
4
S
l
o
t
8
S
l
o
t
9
S
l
o
t
1
0
S
l
o
t
1
1
Fiber Routing
Page143
S
l
o
t
3
5
S
E
P
1
S
l
o
t
1
2
S
l
o
t
1
3
S
l
o
t
1
4
S
l
o
t
1
5
G G
S S
C C
C C
S
l
o
t
1
6
S
l
o
t
1
7
S
l
o
t
1
8
MADM
Page144
Page145
Tributary unit
Line unit
16 x E1s
STM-16
3 x E3s
STM-4
Tributary unit
32 x E1s
3 x E3s
Line unit
STM-16
STM-4
PIU
FAN
Slot 1 PIU
PL3A
Slot 11PL1
Slot 12
SLQ4
Slot 4
Slot 20 CXL16
PIU
FAN
Slot 7
Slot 13
CXL16
Slot 6
Slot 8
EOW
Slot 5 AUX
Slot 9
Slot 10
Slot 1 PIU
Slot 11 L75S
Slot 6
Slot 2 PD1
Slot 12
Slot 7
PL3A
Slot 13
R1SLD4
Slot 8
CXL16
Slot 4EOW
Slot 9
Slot 5AUX
Slot 10
Slot 20 CXL16
Page146
Tributary unit
Line unit
63 x E1s
STM-16
3 x E3s
STM-4
D75S
D75S
C34S
Slot14
PIU
Slot15
Slot16
PIU
Slot 17
Slot19
Slot 11
Slot 6
PQ1
Slot 12
Slot 7
PL3
Slot 13
R1SLD4
Slot8
CXL16
Slot 4EOW
Slot 9
CXL16
Slot 5AUX
Slot 10
Slot 20
FAN
Slot18
Page147
Tributary unit
D
7
5
S
D
7
5
S
D
3
4
S
S
l
o
t
1
S
l
o
t
2
S
l
o
t
3
P
Q
1
P
D
3
S
L
D
4
C
X
L
1
6
C
X
L
1
6
S
l
o
t
6
S
l
o
t
7
S
l
o
t
8
S
l
o
t
9
S
l
o
t
1
0
Line unit
63 x E1s
STM-16
4 x E3s
STM-4
S
l
o
t
4
S
l
o
t
5
S
A
P
S
l
o
t
1
1
S
l
o
t
1
2
S
l
o
t
1
3
S
l
o
t
1
4
S
l
o
t
1
5
S
l
o
t
1
6
S
l
o
t
1
7
S
l
o
t
1
8
SLOT 23
FAN
SLOT 24
FAN
Page148
SLOT 25
PIU
Tributary unit
Line unit
100 x E1s
STM-64
6 x E3s
STM-16
S
l
o
t
1
9
S
l
o
t
2
0
S
l
o
t
2
1
D
7
5
S
S
l
o
t
2
2
S
l
o
t
2
3
D
7
5
S
S
l
o
t
2
4
D
7
5
S
S
l
o
t
2
5
D
7
5
S
S
l
o
t
2
6
P
I
U
P
I
U
FAN
P P P S
D Q Q L
3 1 1 D
4
2 x STM-1e STM-4
S
l
o
t
1
S
l
o
t
2
S
l
o
t
2
9
S
l
o
t
3
0
S
l
o
t
3
3
S
l
o
t
3
4
G
X
C
S
S
L
6
4
S S S S S S
l l l l l l
o o o o o o
t t t t t t
3 4 5 6 7 8
S
l
o
t
9
S
l
o
t
1
0
S
l
o
t
1
2
Fiber Routing
Page149
S
l
o
t
3
5
S
l
o
t
3
6
S
l
o
t
3
7
FAN
G
X
C
S
S
l
o
t
3
2
FAN
S S
L L
1 6
6 4
S
l
o
t
3
1
A
U
X
S
E
P
1
S
l
o
t
1
2
S
l
o
t
1
3
S
l
o
t
1
4
S
l
o
t
1
5
G G
S S
C C
C C
S
l
o
t
1
6
S
l
o
t
1
7
S
l
o
t
1
8
Regenerator
Page150
Regenerator (Cont.)
Page151
Regenerator (Cont.)
S
L
1
6
S
F
1
6
S
L
6
4
C
R
G
C
R
G
S
L
6
4
S
F
1
6
S S
L A
1 P
6
S
l
o
t
6
S
l
o
t
7
S
l
o
t
8
S
l
o
t
9
S
l
o
t
1
0
S
l
o
t
1
1
S
l
o
t
1
2
S
l
o
t
1
3
CRG:
Timing signal
S
l
o
t
1
S
l
o
t
2
S
l
o
t
3
S
l
o
t
4
S
l
o
t
5
S
l
o
t
1
4
S
l
o
t
1
5
S
l
o
t
1
6
S
l
o
t
1
7
S
l
o
t
1
8
SLOT 23
FAN
SLOT 24
FAN
Page152
SLOT 25
PIU
Regenerator (Cont.)
Page153
Regenerator (Cont.)
Page154
Regenerator
Page155
Regenerator (Cont.)
D
3
4
S
Tributary unit
Line unit
100 x E1s
STM-64
6 x E3s
STM-16 (FEC)
2 x STM-1e STM-16
S
l
o
t
1
9
S
l
o
t
2
0
S
l
o
t
2
1
D
7
5
S
S
l
o
t
2
2
S
l
o
t
2
3
D
7
5
S
S
l
o
t
2
4
D
7
5
S
S
l
o
t
2
5
D
7
5
S
S
l
o
t
2
6
A
U
X
P
I
U
P
I
U
FAN
S
l
o
t
1
S
l
o
t
2
S
l
o
t
2
9
S
l
o
t
3
0
S
l
o
t
3
1
S
l
o
t
3
2
S
l
o
t
3
3
FAN
G
X
C
S
G
X
C
S
S S S
L F L
6 1 1
4 6 6
S S S S S S
l l l l l l
o o o o o o
t t t t t t
3 4 5 6 7 8
S
l
o
t
9
S
l
o
t
1
0
S
l
o
t
1
2
Fiber Routing
Page156
S
l
o
t
3
5
S
l
o
t
3
6
S
l
o
t
3
7
FAN
P P P S S S
D Q Q L F L
3 1 1 1 1 6
6 6 4
S
l
o
t
3
4
S
l
o
t
1
2
S
l
o
t
1
3
S
E
P
1
S
l
o
t
1
4
S
l
o
t
1
5
G G
S S
C C
C C
S
l
o
t
1
6
S
l
o
t
1
7
S
l
o
t
1
8
Regenerator (Cont.)
OSN
3500
SL64
SL64
IN
OUT
OUT
IN
IN
OUT
SL64
SL64
IN
OUT
OSN
3500
OSN
3500
IN
OUT
OUT
OUT
IN
IN
IN
OUT
OSN
3500
PQ1
SL16
SL16
SL16
SL16
Page157
ADM
MADM
REG
STM-64
REG
STM-16
STM-1
ADM
ADM
TM
Low-rate signals
Page158
Contents
1.
Product Introduction
2.
Cabinet, Sub-rack
3.
Boards
4.
5.
Features
Page159
Protection scheme
1:2 TPS
1:1 TPS
FE Processing board
Core unit
Slot 20
FAN
SLOT 18 PIU
SLOT 19 PIU
Protection
SLOT 6 (622M)
Working
SLOT 7 (622M)
Slot 20
SLOT 18 PIU
SLOT 19 PIU
SLOT11
SLOT 6 (622M)
Protection
SLOT 7 (622M)
Working
SLOT 8 (622M)
Working
SLOT 8 (622M)
SLOT 9 (622M)
SLOT 9 (622M)
SLOT 10 AUX
SLOT 10 AUX
FAN
Page160
Protection scheme
1:N (N 4) TPS
FE processing board
Core unit
* The OptiX OSN 2500 can support two TPS groups of different types of services at the
same time.
Page161
S
L
O
T
2
S
L
O
T
3
S
L
O
T
4
S
L
O
T
5
S
L
O
T
6
S
L
O
T
7
S
L
O
T
8
S
L
O
T
9
S
L
O
T
10
C
X
L
C
X
L
S
L
O
T
11
W W
S
L
O
T
12
S
L
O
T
13
S
L
O
T
14
S
L
O
T
15
S
L
O
T
16
S
L
O
T
17
S
L
O
T
18
S
L
O
T
1
S
L
O
T
2
S
L
O
T
3
S
A
P
W W
S
L
O
T
4
S
L
O
T
5
S
L
O
T
6
S
L
O
T
7
T
S
B
P
S
L
O
T
8
S
L
O
T
9
S
L
O
T
10
C
X
L
C
X
L
S
L
O
T
11
S
L
O
T
12
S
L
O
T
14
S
A
P
Page162
S
L
O
T
13
S
L
O
T
15
S
L
O
T
16
S
L
O
T
17
T
S
B
S
L
O
T
18
Protection scheme
1:N (N 8) TPS
SCC unit
Page163
Working
Working
Working
S
L
O
T
7
S
L
O
T
8
S
L
O
T
9
S
L
O
T
1
0
FE board1:1 TPS
S
L
O
T
1
1
S
L
O
T
1
2
S
L
O
T
1
3
S
L
O
T
1
4
S
L
O
T
1
5
S
L
O
T
1
6
S
L
O
T
1
7
S
L
O
T
1
8
S S
C C
C C
S
L
O
T
1
S
L
O
T
2
S
L
O
T
1
S
L
O
T
4
S
L
O
T
5
E1 Working
Working
S
L
O
T
6
E1 Working
Protection
S
L
O
T
5
E3 Working
E3 Protection
E1 Protection
S
L
O
T
4
Working
S
L
O
T
3
Working
Working
S
L
O
T
2
Working
S
L
O
T
1
S S S
2 3 L
O
T
4
F F
E E
P W
S
L
O
T
5
S
L
O
T
6
S
L
O
T
7
S
L
O
T
8
S
L
O
T
9
S
L
O
T
1
0
S
L
O
T
1
1
S
L
O
T
1
2
S
1
3
S S
1 1
4 5
E4
/1
5
5
M
E4 E4
/1 /1
5 5
5 5
M M
W WW
S
L
O
T
6
S
L
O
T
7
S
L
O
T
8
S
L
O
T
9
S
L
O
T
1
0
X
C
S
X
C
S
Page164
S
L
O
T
1
1
S
L
O
T
1
2
S
L
O
T
1
3
S S
L 1
O 5
T
1
4 F
E
S S S
1
L L
6
O O
T T
E4
1 1
/1
7 8
5
5
M
S S
P C C
C C
S S S
1 L L
6 O O
T T
1 1
F 7 8
E
S S
C C
W P C C
Fans
Once one fan modules goes faulty, the others will operate at their full
speed.
Page165
Types
1+1 MSP
1:N (1 N 14) MSP
2-fiber bidirectional MSP ring
MSP ring
Mesh Protection
Intelligent function
SNCP
Dual node interconnection (DNI)
Fiber-Shared Virtual Path Protection
MS-Shared Optical Path Protection
RPR
VP-Ring/VC-Ring Protection
Page166
Intelligent Features
Traffic engineering
Page167
Fair algorithm
3 service levels
Page168
Summary
Product Introduction
Features
Page169
Thank you
www.huawei.com