You are on page 1of 170

OptiX OSN 1500/2500/3500

Hardware Description

www.huawei.com

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Objectives

Upon completion of this course, you will be able to:

Appreciate the networking applications of the OptiX OSN


1500/2500/3500

Describe the system structure of the OptiX OSN


1500/2500/3500

Outline the main boards of the OptiX OSN 1500/2500/3500

Outline the system protection schemes of the OptiX OSN


1500/2500/3500

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page2

Contents
1.

Product Introduction

2.

Cabinet, Sub-rack

3.

Boards

4.

Common Network Elements and Configuration

5.

Features

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page3

Product Introduction

What is OSN 1500/2500/3500

Full name: OptiX OSN 1500/2500/3500 intelligent optical


switching system

Form the OptiX OSN NG-SDH Series

OSN1500/2500: Optical convergence or access switching


system
OSN3500: Optical convergence or core switching system

OSN: Optical Switch Node

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page4

Network Application
4010G

160 10G

OptiX BWS 1600G

iManager T2000

10G/2.5G
OSN 3500 /7500/9500

OSN 1500/2500

OSN 2500/Metro

OptiX BWS 1600G

10G
OSN 7500/9500

OSN 2500/3500

OSN1500/Metro

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Long-Haul
Back Bone

10G/2.5G

Core

OSN 3500/7500/9500

OSN 1500/2500

OSN1500/Metro

Page5

Convergenc
e

Access

System Architecture
STM-1
STM-4/16

LU

LU

STM-64
(OSN3500)

LU

Cross-connect Unit HighLU

order matrix
(VC-4)
Low-order matrix
(VC-12/VC-3)

PDH
Ethernet

TU

TU

SAN/Video

TU

TU

ATM

Timing Unit
External
synchronization
interface

Auxiliary Unit

SCC
Unit
Auxiliary
interface

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page6

Management
interface

Large Capacity and Multi-services


Large and multiAccess
services access
STM-1/4/16/64
VC-4-4c/8c/
16c/64c

capacity
SDH unit

SDH unit

West

STM-1/4/16/64
VC-4-4c/8c /
16c/64c

East

Cross-connect matrix
Large cross-connect
capacity

Multi-granularity
cross-connect
capacity
PDH
Interface
unit

E1/T1/E3/T3/E4

Ethernet
Interface
unit

FE/GE

Other
Interface
unit

ATM/SAN/Video

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page7

Contents
1.

Product Introduction

2.

Cabinet, Sub-rack

3.

Boards

4.

Common Network Elements and Configuration

5.

Features

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page8

Cabinet
ETSI 300/600 Cabinet
W(mm)

D(mm)

H(mm)

600

2000

600

2200
300

2600

Max. number of Sub-racks


Height
(mm)

mounted
OptiX
OSN
1500

H
W

OptiX OSN
2500

OptiX
OSN
3500

2000

2200

2600

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page9

Indicators
Indicator
Power

Power Critical Major Minor

Power distribution Boards

Critical alarm
Major alarm
Minor alarm

Color

Status

Description

On

Cabinet is powered ON

Off

Cabinet is OFF

On

Critical alarm

Off

No critical alarm

On

Major alarm

Off

No major alarm

On

Minor alarm

Off

No minor alarm

Note:
Indicators do not flash
If alarm indicator is ON, alarm occurs on one or more sub-racks
inside the cabinet

Alarms occur on sub-racks, ALM cable should be properly


connected

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page10

Power Distribution Unit


1

3
2
OUTPUT

3 4

ON

3
2
OUTPUT

ON
RTN1(+) RTN2(+) NEG1(-) NEG2(-)

OFF
32A

32A

20A

INPUT
20A

1. Power socket (left)

2. Power cable
RTN1(+)

OFF
32A

32A

20A

20A

3. Power cable
RTN2(+)

4. Power cable NEG1() 5. Power cable NEG2() 6. Power socket


(right)
A: Supply for Left Power interface

From Left, the 1st switch supplies the lower sub-rack

B: Supply for Right Power interface


7500/3500

The 1 st & 2nd switches are mainly for the OptiX OSN

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page11

Power Consumption

DC power supply

Normal voltage: -48V or -60V

Range of input voltage: -48V20%(or -60V20 )

Equipment

OptiX OSN
1500A

OptiX
OSN
1500B

OptiX

OptiX OSN

OSN 2500

3500

Power
Consumption
(W)
Fuse Capacity
(A)

200

280

400

600

10

10

15

20

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page12

OptiX OSN 1500A Sub-rack


PIU
Service slot area
Core
Unit
Auxiliary Unit
FAN box

Dimensions
(mm)
Weight (kg)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

133 (H) x 444 (W) x 262 (D)


8 (without boards and fans)

Page13

OptiX OSN 1500A Sub-rack


(Cont.)
SLOT 1

SLOT 20
FAN

SLOT 11

SLOT 6

1.25G

2.5G

SLOT 7 1.25G

SLOT 3

2.5G

SLOT 8 1.25G

SLOT 4

2.5G

SLOT 9 1.25G

SLOT 5

2.5G

SLOT 10

l it
sp

SLOT 2

SLOT 1

SLOT 20
FAN

SLOT 11

SLOT 6

1.25G

SLOT 2

1.25G

SLOT 12

1.25G

SLOT 7

1.25G

SLOT 3

1.25G

SLOT 13

1.25G

SLOT 8

1.25G
1.25G

SLOT 4

2.5G

SLOT 9

SLOT 5

2.5G

SLOT 10

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page14

OptiX OSN 1500B Sub-rack


Interface slot area
PIU
Service slot area
Core
Unit
Auxiliary Unit
FAN box
Dimensions
(mm)
Weight (kg)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

221 (H) x 444 (W) x 262 (D)


9 (without boards and fans)

Page15

OptiX OSN 1500B Sub-rack


(Cont.)
Slot Relation
SLOT 14

SLOT 18 PIU

SLOT 15

13 16,17

SLOT 16

SLOT 19 PIU

SLOT 17
SLOT 11

2.5G

SLOT 6 622M

15

SLOT 1 2

2.5G

SLOT 7

622M

17

SLOT 1 3

2.5G

SLOT 8

622M

SLOT 4

2.5G

SLOT 9

622M

SLOT 5

2.5G

SLOT 10

Slot Relation 7
(After split)
8

l it
sp

SLOT 20
FAN

12 14,15

SLOT 14

15

SLOT 18 PIU

SLOT 15
SLOT 16

17

SLOT 19 PIU

SLOT 17

14

12

15

16

13

17

SLOT 20
FAN

SLOT 1 1.25G

SLOT 11 1.25G

SLOT 6

622M

SLOT 2 1.25G

SLOT 12 1.25G

SLOT 7

622M

SLOT 3 1.25G

SLOT 13 1.25G

SLOT 8

622M
622M

SLOT 4

2.5G

SLOT 9

SLOT 5

2.5G

SLOT 10

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page16

OptiX OSN 2500 Sub-rack


SEI (Auxiliary
Boards)
Service slot
area
Interface slot area
Core Unit
SAP (Auxiliary Unit)
PIU
FAN Unit
Dimensions
(mm)
Weight (kg)

447 (W) x 295 (D) x 472 (H)


17 (without boards and fans)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page17

OptiX OSN 2500 Sub-rack (Cont.)


S
L
O
T
12

OO O O
T T T T
1 2 3 4 6

6 2 2 2 2 2 2
2 2 . . . . . .
2 2 5 5 5 5 5 5
M M G G G G G G

S
L
O
T
13

S
L
O
T S S S S
L L L L
14

OO O O
T T T T
S 15 16 17 18

1
. A
2 P
5
G

Fiber routing panel


SLOT 22
PIU

SLOT 23
FAN

SLOT 24
FAN

Slot Relation 20
6
(After split)

12
13

1
2

SLOT 25
PIU

21
7

3
4

1, 2

3, 4

13 17, 18
S
L
O
T
19
S S S S 622
L L L L M

O O O O
T T T T S
1 2 3 4 L

O
T
5
622
M

15 1
6
17 1

12 15, 16

li t
sp

S S S S S S S
L L L L L L L
O O O O O O O
S S S S T T T T T T T
L L L L
5 6 7 8 9 10 11

Slot Relation

S S
L L
O O
T T
20 21
622 1.25
M G
S S
L L
O O
T T
6 7
622 1.25
M G

S S S S
L L L L
O O O O
T T T T
8 9 10 11

S
L
O
T
12

S
L
O
T
13

S
L
O
T S S S S
L L L L
14

O O O O
T T T T
S 15 16 17 18

2 2 2 2 2 1
. . . . . . A
5 5 5 5 5 25 P
G G G G G G

Fiber routing panel


SLOT 22
PIU

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

SLOT 23
FAN

Page18

SLOT 24
FAN

SLOT 25
PIU

OptiX OSN 3500 Sub-rack


Interface slot area
Auxiliary Unit
PIU
FAN boxes
Service slot area
SCC Unit
Cross-connect Unit
Air filter
Dimensions

497 (W) x 295 (D) x 722

(mm)

(H)

Weight (kg)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

20 (without boards and


fans)

Page19

OptiX OSN 3500 Sub-rack (Cont.)

Slot Relation
2 19, 20

S
L
O
T
1
9

S
L
O
T
2
0

S S
L L
O O
T T
2 2
1 2

S
L
O
T
2
3

S
L
O
T
2
4

S
L
O
T
2
5

S
L
O
T
2
6

3 21, 22
4 23, 24
5 25, 26
13 29, 30
14 31, 32

S
L
O
T
2
7

S
L
O
T
2
8

P
I
U

P
I
U

FAN
S
L
O
T
1

S
L
O
T
2

S
L
O
T
3

S
L
O
T
4

S
L
O
T
2
9

S
L
O
T
3
0

S
L
O
T
3
1

S
L
O
T
3
2

S
L
O
T
6

S
L
O
T
7

S
L
O
T
8

S
L
O
T
3
5

S
L
O
T
3
6

S
L
O
T
3
7

S
L
O
T
9

S
L
O
T
10

XCS

XCS

FAN
S S S
L L L
O O O
T T T
11 12 13

15 33, 34
16 35, 36
Fiber Routing
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

S
L
O
T
3
4

A
U
X

FAN
S
L
O
T
5

S
L
O
T
3
3

Page20

S S S S S
L
L L
L L
O O O O O
T T T T T
14 15 16 17 18
S
C
C

S
C
C

OptiX OSN 3500 Sub-rack (Cont.)

Configure 1

Access capacity :

FAN

35G

622 M x 8

2.5 G x 4

10 G x 2

FAN

FAN

S
L
O
T
1

S
L
O
T
2

S
L
O
T
3

S
L
O
T
4

S S S S
L L L L
O O O O
T T T T
5 6 7 8

S
L
O
T
9

S
L
O
T
10

S
L
O
T
11

S
L
O
T
12

S
L
O
T
14

S
L
O
T
15

S
L
O
T
16

6
2
2
M

6
2
2
M

6
2
2
M

6
2
2
M

6 2 2 10
2 . . G
2 5 5
M G G

G
X
C
S

G
X
C
S

10 2 2 6
G . . 2
5 5 2
G G M

6
2
2
M

6
2 S S
2 C C
M C C

Fiber Routing

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page21

S
L
O
T
13

S
L
O
T
17

S
L
O
T
18

OptiX OSN 3500 Sub-rack (Cont.)

Configure 2

Access capacity :

FAN

58.75G

1.25 G x 7

2.5 G x 4

10

Gx4

FAN

FAN

S
L
O
T
1

S
L
O
T
2

S
L
O
T
3

S
L
O
T
4

S S S S
L L L L
O O O O
T T T T
5 6 7 8

S
L
O
T
9

S
L
O
T
10

S
L
O
T
11

S
L
O
T
12

S
L
O
T
15

S
L
O
T
16

S
L
O
T
17

1
.
2
5
G

1
.
2
5
G

1
.
2
5
G

1 2 2 10 10
. . . G G
2 5 5
5 G G
G

E
/
U
X
C
S

E
/
U
X
C
S

10 10 2 2 1
G G . . .
5 5 2
G G 5
G

1
.
2
5
G

1.
25
G S
/ C
S C
C
C

Fiber Routing

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page22

S
L
O
T
13

S
L
O
T
14

S
L
O
T
18

OptiX OSN 3500 Sub-rack (Cont.)

Configure 3

Access capacity :

FAN

155G

5 Gx 7

10 G x 4

20 G x 4

S
L
O
T
1

S
L
O
T
2

S
L
O
T
3

S
L
O
T
4

FAN

FAN

S S S S
L L L L
O O O O
T T T T
5 6 7 8

S
L
O
T
9

S
L
O
T
10

S
L
O
T
11

S
L
O
T
12

5 5 5 5 10 10 20 20
G G G G G G G G

S
X
C
S

S
X
C
S

20 20 10 10 5 5 5G S
G G G G G G S/ C
C C
C

Fiber Routing

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page23

S
L
O
T
13

S
L
O
T
14

S
L
O
T
15

S
L
O
T
16

S
L
O
T
17

S
L
O
T
18

Questions

Please list the slot access capacity of the equipment.

Do you remember the relation between the processing


board slot and the interface board slot in different
equipment?

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page24

Contents
1.

Product Introduction

2.

Cabinet, Sub-rack

3.

Boards

4.

Common Network Elements and Configuration

5.

Features

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page25

Contents
3.

Boards
3.1 SDH Unit
3.2 PDH Unit
3.3 Ethernet Unit
3.4 ATM Unit
3.5 MST Unit
3.6 WDM Unit
3.7 Cross-connect and System Control Unit
3.8 Auxiliary Unit

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page26

SDH Unit

Boards appearance type

Processing with Interface

Processing

Interface
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page27

SDH Unit (Cont.)


SDH

Line Unit

16

Digital rate:
- : 1*STM-N signal
64:STM-64
D: 2*STM-N signals

Q: 4*STM-N signals 16:STM-16


4:STM-4
O: 8*STM-N signals 1:STM-1
T: 12*STM-N signals
H: 16*STM-N signals

Can you tell the main function of


SL64?
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page28

SDH Unit (Cont.)

Board Description
Connecto

Board

Full name

Module available

SF64

1 x STM-64 processing with optical


interface board (FEC)

Fixed wavelength output, I-64.2, S64.2b, L-64.2b, Le-64.2, Ls-64.2, V-64.2b


(with BA, PA, and DCU)

SL64

1 x STM-64 processing with optical


interface board

Fixed wavelength output, I-64.2, S-

SF16

1 x STM-16 processing with optical


interface board (FEC)

Fixed wavelength output


Ve-16.2c, Ve-16.2d, and Ve-16.2f

SLQ16

4 x STM-16 processing with optical


interface board

I-16, S-16.1, L-16.1, L-16.2

SL16 (A)

1 x STM-16 processing with optical


interface board

r type

64.2b, L-64.2b, Le-64.2, Ls-64.2,V-64.2b

Fixed wavelength output, I-16, S-16.1, L16.1, L-16.2, L-16.2Je, V-16.2Je (with
BA), and U-16.2Je (with BA and PA)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page29

LC

SDH Unit (Cont.)


SL 64

4 indicators

STAT
ACT
PROG
SRV

SF64
STAT
ACT
PROG
SRV

SF16
STAT
ACT
PROG
SRV

SL16
STAT
ACT
PROG
SRV

SLQ16
S TAT
ACT
P ROG
S RV

SL16A

SFP Module

STAT
ACT
PROG
SRV

CLASS1
LASER
PRODUCT
CLASS 1
LASER
PRODUCT

CLASS 1
LASER
PRODUCT

CLASS 1
LASER
PRODUCT

CLASS 1
LASER
PRODUCT

CLASS 1
LASER
PRODUCT

LC Connector
O U T 1IN 1
O U T I2N 2

OUT

OUT

OUT

IN

IN

IN

IN

OUT

O U T 3IN 3
IN

O U T 4IN 4

Electrostatic
Discharge

OUT

SL64

SF64

SF 16

SL16

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

SLQ4

Page30

SL16A

CLASS 1
LASER
PRODUCT

SDH Unit (Cont.)

Slot available
Slot available
Board
Name

OSN

OSN

OSN

1500A

1500B

2500

SF64
SL64
SF16
SL16(A)

12, 13

11~13

SLQ16

7, 8,
11 ~ 13

OSN 3500
40G

80G

8, 11

7, 8, 11, 12

6 ~ 8,
11 ~ 13

5 ~ 8, 11 ~ 14

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

200G

1 ~ 8, 11 ~
16

Page31

SDH Unit (Cont.)

Board Description

Board
SLQ4
SLD4
SL4
SLT1
SLO1
SLQ1
SL1

Full name

Module available

Connector
type

4 x STM-4 processing with optical interface


board
2 x STM-4 processing with optical interface
board
1 x STM-4 processing with optical interface

I-4, S-4.1, L-4.1, L4.2, Ve-4.2

board
12 x STM-1 processing with optical interface

LC

board
8 x STM-1 processing with optical interface
board
4 x STM-1 processing with optical interface

I-1, S-1.1, L-1.1, L1.2, Ve-1.2

board
1 x STM-1 processing with optical interface
board

Signal processing with optical interface board

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page32

SDH Unit (Cont.)


SLD4

S LQ4

STAT
ACT
PROG
SRV

STAT
ACT
PROG
SRV

SL4
STAT
ACT
PROG
SRV

CLASS1

CLASS1
LASER
PRODUCT

LASER
PRODUCT

CLASS1
LASER

O U T 2IN 2
SL4

SLT1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

CLASS1
LASER
PRODUCT

OUT

IN

O U T 4IN 4

O U T 4I N 4
SLD4

CLASS1
LASER
PRODUCT

O U T 3I N 3

O U T 3I N 3
SLQ4

CLASS1
LASER
PRODUCT

O U T 2IN 2

O U T 1IN 1

O U T I2N 2

CLASS 1
LASER
PRODUCT

SL1
STAT
ACT
PROG
SRV

O U T 1IN 1

O U T 1I N 1

IN

STAT
ACT
PROG
SRV

O U T1IN 1 O U T2 IN 2 O U T3IN 3 O U T4 IN 4 O U T5IN 5 O U T6 IN 6 O U T7IN 7 O U T8IN 8

OUT

SLQ1

SLO1
STA T
ACT
PR OG
SR V

O U T I1N 1 O U T 2IN 2 O U T I3N 3 O U T 4I N 4 O U T 5I N 5 O U T I6N 6 O U T I7N 7 O U T I8N 8 O U T I9N 9 O U T 1I N0 1 0O U T 1I N1 1 1O U T 1I N2 1 2

PRODUCT

SLT1
STAT
ACT
PROG
SRV

CLAS S1
LASE R
PRODUCT

SLO1

SLQ1

Page33

SL1

SDH Unit (Cont.)


Slot available
Board
Name

OSN

OSN

1500A

1500B

OSN 3500
OSN 2500

6 ~ 8,

SLQ4

SLT1

80G
5 ~ 8, 11 ~ 14

11 ~

SLD4
SL4

40G

13
12, 13

11~13

5 ~ 8,
11 ~ 13

1 ~ 8,

SLO1

11 ~

SLQ1

16

1 ~ 8, 11 ~ 17

SL1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page34

200G

SDH Unit (Cont.)


Boards Description

Board
SEP1

Full name
2 x STM-1 processing with electrical
interface board

Board

Full name

SLH1

16 x STM-1 processing board

SEP

8 x STM-1 processing board

Board

Full name

OU08

8 x optical signal access board


8 x electrical signal access

EU08
EU04
Board
TSB4
TSB8

board
4 x electrical signal access
Full name
board
Tributary Switch Board for 4

Signal
processing with
electrical
interface board

Connector type
SMB

Signal processing

Connector (Interface)
type
LC/SC (I-1 and S-1.1)

Interface

SMB
SMB

TPS

signals
Tributary Switch Board for 8
signals

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page35

SDH Unit (Cont.)

SEP1

No need for interface board

SMB interfaces on the front panel are used

Can be inserted in all line slots

SEP

Need interface board: EU08, OU08, EU04

SMB interfaces on the front panel are inhibited

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page36

SDH Unit (Cont.)

OUT1 IN1

OUT2 IN2

OUT3 IN3

OUT4 IN4

OUT5 IN5

OUT6 IN6

OUT7 IN7

OUT1IN1OUT2IN2OUT3IN3OUT4IN4OUT5IN5OUT6IN6OUT7IN7OUT8IN8

O UT1IN1 O UT2IN2 O UT3IN3 O UT4IN4

AOUT AIN BOUTBIN

OUT8 IN8

Page37
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

TSB8

OU08
OU08
EU04
EU08

CLASS 1
LASER
PRODUCT

C
o
n
n
e
c
t
o
r

SEP1

SLH1

SFP Module
OUT1IN1 OUT2 IN2 OUT3IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 O UT8IN8

S
M
B

TSB8

OU08
OU08
EU04
EU08

SC Connector
STAT
ACT
PROG
SRV
STAT
ACT
PROG
SRV

SEP1

SLH1

SDH Unit (Cont.)

Slot available
Board
Name
SEP1

OSN

OSN

OSN

1500A

1500B

2500

12,13

11~13

5 ~ 8,
11 ~ 13

SLH1
SEP
OU08
EU08

40G

80G

OSN 7500
200G

1 ~ 6, 13 ~ 16
2 ~ 5,
13 ~
16

12, 13

6 ~ 7,
12 ~ 13

2 ~ 5, 13 ~ 16

14, 16

1 ~ 4,
15 ~ 18

19, 21,
19 ~
23, 25,
26, 29

29, 31,
~ 36
33, 35
19, 21, 23, 25, 29, 31,
33, 35

14

1,17

19,35

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

240G

360G

1 ~ 3, 17, 18

EU04
TSB4
TSB8

Slot available
OSN 3500

2, 3, 17, 18

19 ~ 22, 35 ~
38

37,38

Page38

SDH Unit (Cont.)

Boards Description

Board
R1SLD4
R1SL4
R1SLQ1
R1SL1

Full name

Connector

Module available

type

2 x STM-4 processing with


optical interface board

I-4, S-4.1, L-4.1, L-4.2, Ve-

STM-4 processing with

4.2

optical interface board

LC

4 x STM-1 processing with


optical interface board

I-1, S-1.1, L-1.1, L-1.2, Ve-

STM-1 processing with

1.2

optical interface board


Signal processing with optical interface board

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page39

SDH Unit (Cont.)


SFP Module

R1SLD4

R1SL4
STAT
ACT
PROG
SRV

STAT
ACT
PROG
SRV

R1SLQ1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

O U TIN

R1SL4

R1SL1
STAT
ACT
PROG
SRV

O U T 1IN 1 O U T 2IN 2 O U T 3IN 3 O U T 4IN 4

O U T IN

O U T 1IN 1 O U T 2IN 2
R1SLD4

R1SLQ1
STAT
ACT
PROG
SRV

R1SL1

Page40

SDH Unit (Cont.)

Slot available
Slot available
Board
Name

OSN

OSN

OSN

1500A

1500B

2500

1 ~ 3, 11
~ 13

7, 21

R1SLD4
R1SL4
R1SLQ1
R1SL1

2, 3, 6 ~
9, 12, 13

1 ~ 3, 6
~ 9, 11 ~
13

OSN 3500
40G

80G

200G

5 ~ 7,19
~ 21

R1- boards are used in the small slots in OptiX OSN 1500 or when slots are
segmented in OptiX OSN 1500/2500.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page41

SDH Unit (Cont.)

Indicator
Indicator
STAT
Board
Status

ACT
Board
Activation

Status

Color

Description

On, green

Board works normally.

On, red

Board hardware fails.

Off

Board is powered off.

On, green

Board is activated/configured.

Off

Board is not activated/configured.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page42

SDH Unit (Cont.)

Slot available
Indicat
or

PROG
Board
Software

Status

Color

Description

On, green

Upload of board software to FLASH or the


FPGA upload is normal, or the board
software initialization is normal.

On for 100ms and off for


100ms alternatively,
green

Board software is being uploaded to FLASH


or FPGA.

On for 300ms and off for


300ms alternatively,
green

Board software is initializing, and is in BIOS


boot stage.

On, red

Board software in FLASH or the FPGA


configuration is lost, resulting in upload
and initialization failure.

Off

No power supply.

On, green

Service is normal and no service alarm


occurs.

SRV
Critical or major alarm occurs to service.
On, red
Service
Alarm 2006
Minor
or remote alarm occurs to service.
Copyright
reserved.
On,Huawei
yellowTechnologies Co., Ltd. All rights

Page43

SDH Unit (Cont.)

Functions of SL16
Collect Alarm
and
performance

C
o SC
t
d
Sen

TR
U-P
A
and ssing
H
O
ce
pro
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page44

Send to Cross-connect
unit

STM-16

16
X
VC
4

SDH Unit (Cont.)

Features of SL16

Fixed wavelength output

Automatic laser shutdown (ALS) function

Swappable optical module (SFP)

Support VC-4-4c, VC-4-8C and VC-4-16c


services

Inloop and outloop function

Setting and querying of the REG working


mode

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

1 Last six digits of BOM


2 Internal number
3 Board version
4 Board name
5 Board characteristic number

Page45

SDH Unit (Cont.)

Optical port parameters of SL16

Optical interface type

I-16
(01)

S16.1
(02)

L-16.1
(03)

L-16.2
(04)

L16.2Je
(02)

V-16.2Je
(BA)
(03)

U-16.2Je
(BA+PA) (04)

Wavelength (nm)

1310

1310

1310

1550

1550

1550

1550.12

Distance (km)

02

2 15

15 40

40 80

80
100

80 140

140 170

Launched power (dBm)

-10~3

-5~0

-2~3

-2~3

5~7

14

17

-18

-18

-27

-28

-28

-28

-34

-3

-9

-9

-9

-9

-10

(Board characteristic
#)

Receiver sensitivity
(dBm)
Receiver overload
(dBm)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page46

SDH Unit (Cont.)

Common alarms of SDH

unit
Alarm

level
Critical

Major

Colo
r

Alarm
name
R_LOS
MS_AIS
AU_AIS
POWER_
ABNORMAL
MS_RDI

Minor
HP_RDI
LOOP_ALM

Alarm reason
Receiver can not receive STM-N signal normally.
Critical alarm e.g. R_LOS happens.
Critical alarm e.g. R_LOS happens.
Wrong service configuration
Faulty SDH board
Power module of the line board fails.
Opposite station receives the R_LOS, R_LOF or MS_AIS
signal
Faulty receiver at the opposite node or transmitter at
the local node
Opposite node receives such alarms as AU_AIS and
AU_LOP.
Faulty receiver at the opposite node or transmitter at
the local node
Software inloop or outloop is being performed.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page47

SDH Unit (Cont.)

Common performance events of SDH unit


Performance name

Performance meaning

RSBBE

Regenerator section block of background error

MSBBE

Multiplex section block of background error

MSFEBBE

Multiplex section far end block of background error

HPBBE

High-order path block of background error

HPFEBBE

High-order path far end block of background error

RPLCUR

Current value of input optical power

RPLMAX

Maximum value of input optical power

RPLMIN

Minimum value of input optical power

TPLCUR

Current value of output optical power

TPLMAX

Maximum value of output optical power

TPLMIN

Minimum value of output optical power

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page48

PDH Unit
Board
Name

Description

Interface board

SPQ4

Processes 4 x E4/STM-1

MU04

PD3

Processes 6 x E3/T3

D34S

PL3

Processes 3 x E3/T3

C34S

PL3A

Processes 3 x E3/T3

PQM

Processes 63 x E1/T1

PQ1

Processes 63 x E1

PD1

Processes 32 x E1/T1

L75S,L12S,D75S,D12S,D12B

PL1

Processes 16 x E1/T1

D75S, D12S, D12B

PD1 and PL1 are used in the small slot in OptiX OSN 1500/2500.

L75S/L12S can be only used in OptiX OSN 1500A.

PD1 cooperates with L75S/L12S in OptiX OSN 1500A, and cooperates with
D75S/D12S in OptiX OSN 2500 or OptiX OSN 1500B.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page49

PDH Unit (Cont.)


Slot available

Slot available
Board
Name

OSN

OSN

OSN

1500A

1500B

2500

SPQ4
PD3

C34S

80G

200G

6, 7,
12, 13

2 ~ 5, 13 ~ 16

12, 13

11~13

5 ~ 8,
11 ~
13

1 ~ 8, 11 ~
16

14, 16

1, 3,
15, 17

19, 21, 23, 25, 29, 31, 33, 35

MU04
D34S

40G

12, 13

PL3
PL3A

OSN 3500

1 ~ 8, 11 ~ 17

PL3A is a processing board with cables led out from the front panel. .

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page50

PDH Unit (Cont.)

SPQ4/MU04

SPQ4

M U 04

STAT
ACT
PROG
SRV

SMB connector

Indicators

O U T 1 IN 1 O U T 2 IN 2 O U T 3IN 3 O U T 4 IN 4

SPQ4

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

M U 04

Page51

PDH Unit (Cont.)


PD3
STAT
ACT
PROG
SRV

PL3
STAT
ACT
PROG
SRV

D34S

P L3A

C34S

STAT
ACT
PROG
SRV

SMB connector
Indicators

PL3A

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

D34S

O U T 1I N 1 O U T 2I N 2 O U T 3I N 3

PL3

O U T 1I N 1 O U T 2I N 2 O U T 3I N 3 O U T 4I N 4 O U T 5I N 5 O U T 6I N 6

O U T 1I N 1 O U T 2I N 2 O U T 3I N 3

PD3

C34S

Page52

PDH Unit (Cont.)

Slot available
Slot available
Board
Name

PQM
PQ1

OSN 3500

OSN

OSN

1500A

1500B

11 ~
13

14 ~ 17

1 ~ 5, 13 ~ 16

14 ~
17

1 ~ 4, 15 ~ 18

19 ~ 26, 29 ~ 36

OSN 2500

40G

80G

D75S
D12S
D12B

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page53

200G

PDH Unit (Cont.)


Slot available

Slot available
Board
Name

OSN

OSN

OSN

1500A

1500B

2500

PD1

2, 12

1 ~ 3, 6
~ 8, 11
~ 13

PL1

6~9

6~9

6~7

L75S
L12S

5 ~ 7, 19
~ 21

OSN 3500
40G

80G

200G

PL1 is a processing board with cables let out from the front panel.

PD1/PL1 can be used in the small slot or used when slots are segmented in OptiX OSN
1500/2500.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page54

PDH Unit (Cont.)


Indicators
PQ1
STAT
ACT
PROG
SRV

DB44
D 75 S

PQM

D 12 S

D12B

STAT
ACT
PROG
SRV

18

18

18

2mmHM

L12S

L75S
1 72 4

1 72 4

1 72 4

D12S

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

D12B

Page55

1-16

D75S

1-1 6

2 53 2

2 53 2

2 53 2

PQM

91 6

PL1
STAT
ACT
PROG
SRV

1-16

PQ1

91 6

91 6

PD1
STAT
ACT
PROG
SRV

PDH Unit (Cont.)

Functions of PQ1

C
o SC
t
d
Sen

1 X VC4

63
X
E1
E1

and
H
O
LP

PTR
U
T

s s in
e
c
pro

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page56

Send to Cross-connect
unit

Collect Alarm
and
performance

PDH Unit (Cont.)

Features of PQ1

Interface Type: 75 or 120

Support Inloop and outloop functions

Support Warm and Cold reset

Support TPS function

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page57

PDH Unit (Cont.)

Common alarms of PDH unit


Alarm

Colo

level

Alarm name
ALM_SUBCARD_ABN

Major

T_ALOS

Alarm reason
The interface board and the processing
board are mismatched
No E1 service is accessed
Critical alarm e.g. R-LOS happens

TU_AIS

Wrong service configuration


Faulty PDH board

Minor

LP_RDI
LP_REI

Opposite node receives such alarms as


TU_AIS and TU_LOP
LPBBE happens on the opposite node

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page58

PDH Unit (Cont.)

Common performance of PDH unit


Performance name

Performance meaning

LPBBE

Low-order path block of background error

LPFEBBE

Low-order path far end block of background error

LPES

Low-order path errored second

LPFEES

Low-order path far end errored second

TUPJCHIGH

Count of positive TU pointer justifications

TUPJCLOW

Count of negative TU pointer justifications

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page59

Ethernet Unit
Number of ports on the front panel

Ethernet

G: Gigabit Ethernet (GE) T: Transparent transmission


S: L2 switching
F: Fast Ethernet (FE)
R: RPR (Resilient Packet Ring
M: Multiple (GE+FE)

Note:

If there is no port on the board, then the board must work with an interface board.
ETF8/EFF8 is the interface board. ETF8 accesses 8FE twisted pair signal, and
EFF8 accesses 8FE optical signal

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page60

Ethernet Unit

Boards Description
Board

Full name

Interface type

Connector

EGS4

4 x GE with L2 switching
processing with interface
board

1000BASE-SX/LX/ZX

LC

EGS2

2 x GE with L2 switching
processing with interface
board

1000BASE-SX/LX/ZX

LC

EGT2

2 x GE transparent
transmission processing with
interface board

1000BASE-SX/LX/ZX

LC

EMS4

4 GE + 16 x FE with L2
switching processing with
interface board

1000BASE-SX/LX/ZX,
100Base-FX (From interface
board)

RJ-45, LC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page61

Ethernet Unit (Cont.)


EGS 2

EGS4
STAT
ACT
PROG
SRV

EMS4

EG T 2

STAT

STAT
ACT
PROG
SRV
LINK1
ACT1
LINK2
ACT2

STAT
ACT
PROG
SRV
LINK1
ACT1
LINK2
ACT2

ACT
PROG
SRV

CLASS 1

CLASS 1
LASER
PRODUCT

LASER
PRODUCT

CLASS 1
LASER
PRODUCT

CLASS 1
LASER
PRODUCT

O U T 2IN 2

O U T 2IN 2

O U T 1IN 1

O U T 1IN 1

O U T 2IN 2

O U T 2IN 2

O U T 1IN 1

O U T 1IN 1

O U T 3IN 3

O U T 3IN 3

O U T 4IN 4

O U T 4IN 4
LINK

LINK

ACT

CLASS 1
LASER
PRODUCT

Indicator
LINK

EG S2

EG T 2

Status

EM S4

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Description

On

Link is established

Off

Link is not established

Flashin

ACT

ACT
EGS4

Color

g
Off

Page62

Data exchanged
No data being
exchanged

Ethernet Unit (Cont.)


Board

Full name

EGR 2

EMR0

STAT
ACT
PROG
SRV
LINK1
ACT1
LINK2
ACT2

EGR2

2 x GE RPR processing with interface board

EMR0

1 GE + 4 (12) x FE RPR processing with interface board

STAT
ACT
PROG
SRV
LINK
ACT

CLASS 1

O U T 2IN 2

O U T 1IN 1

Function

LASER
PRODUCT

O U T 1IN 1

CLASS 1

LASER
PRODUCT

EVPL/EVPLAN Service

FE1

QoS
FE2

Resilient Packet Ring Function

Weighted fair algorithm and three service levels

Auto discovery of topology

Wrap and steering protection

FE3

GE PORT
SFP Module
FE PORT
RJ 45 connector

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page63

FE4

EGR2

EMR0

Ethernet Unit (Cont.)

Slot available
Slot available
Board
Name

EGS4
EGS2
EGT2
EMS4

OSN

OSN

OSN

1500A

1500B

2500

40G

80G

200G

12, 13

EGR2
12, 13
EMR0

OSN 3500

11 ~ 13

5 ~ 8, 11
~ 13

(11)12,
13
(11)12,
13

1 ~ 8, 11 ~ 16

1 ~ 6, 13 ~ 16
6, 7, 12,
13

1 ~ 8, 11 ~ 16

5 ~ 8, 11
~ 13

1 ~ 6, 13 ~ 16

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

1 ~ 4, 15
~16

Page64

Ethernet Unit (Cont.)

Boards Description

Board

Full name

Interface type

Connector

EFS4

4 x FE with L2 switching
processing with interface board

10Base-T/ 100Base-TX

RJ-45

EFS0

8 x FE with L2 switching
processing board

EFT8

8 (16) x FE transparent
transmission processing with
interface board

10Base-T/ 100Base-TX

RJ-45

10Base-T/ 100Base-TX

RJ-45

10Base-T/ 100Base-TX

RJ-45

100Mbit/s-FX

LC

ETF8
ETS8
EFF8

8 x FE twisted pair signal access


board
8 x FE twisted pair signal access
switching board
8 x FE optical signal access board

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page65

Ethernet Unit (Cont.)


EFS4
STAT
ACT
PROG
SRV

EFS0

EFT 8

STAT
ACT
PROG
SRV

STAT
ACT
PROG
SRV

RJ 45 connector

FE1

FE2

FE1
FE3

FE4

EFT 4

FE2

STAT
ACT
PROG
SRV

FE5

FE6

FE3

FE7

FE1

FE8

FE2
FE3

FE4

FE4

EFS4

EFS0

EFT8

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page66

Ethernet Unit (Cont.)


ETS8

EFF 8

ETF8

1
2
3
4
5
6
7
8

FE PORT
RJ 45
Connector

LINK ACT

FE2 FE3
FE4

FE1 FE2
FE6 FE7

FE8

FE5

FE5 FE6 FE7

FE3 FE4

O U T 1IN 1O U T 2IN 2 O U T 3IN 3O U T 4IN 4O U T 5IN 5O U T 6IN 6 O U T 7IN 7O U T 8IN 8

FE1

CLASS 1
LASER
PRODUCT

Board
Name

Interface Board

EFT8

ETF8,EFF8

EFS0

ETF8,EFF8,EFS8

EMS4
EMR0

ETF8,EFF8

FE8

ETS8

EFF8

ET F8

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page67

Ethernet Unit (Cont.)

Boards Description
Slot available
Board
Name

EFS4

OSN

OSN

1500A

1500B

12, 13

11 ~
13

EFS0

OSN 3500
OSN 2500
5 ~ 8, 11 ~
13
6, 7, 12, 13
7, 12, 13
(5 ~ 8, 11
~ 13)

40G

80G

200G

1 ~ 8, 11 ~ 16 (17)
2 ~ 5, 13 ~ 16

12 ~
13

EFT4

2, 3, 6,
9, 12,
13

1 ~ 3,
6 ~ 9,
12, 13

5 ~ 7, 19 ~
21

ETF8
ETS8
EFF8

14 ~
16

1, 3, 15, 17

19, 21, 23, 25, 29, 31, 33, 35

EFT8

1 ~ 6, 13 ~ 16

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page68

Ethernet Unit (Cont.)

Function of EFS4

Collect Alarm
and
performance

4
X
FE

GFP
NVC12/VC3
VC-12Xv(x63), VC3-Xv(x12)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

8 X VC4

Page69

Send to Cross-connect
unit

FE

SCC
o
t
d
Sen

Ethernet Unit (Cont.)

Features of EFS4

Supports bandwidth auto-sensing

Supports MPLS

Supports LCAS

Supports Port based flow control

Supports receiving and transmitting Ethernet testing frame

Supports inloop at Ethernet port and inloop and outloop at VC3


level

Supports port level Ethernet performance monitoring

Supports EPL/EPLAN/EVPL/EVPLAN services and QoS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page70

Ethernet Unit (Cont.)

Common alarms of Ethernet unit


Alarm
level
Critical

Major

Color

Alarm name
HARD_BAD
ETH_LOS
TU_AIS_VC3
PROTOCOL_MM
LP_RDI_VC3

Minor

LCAS_BAND_
DECREASED

Alarm reason
Faulty board hardware
Interrupted Ethernet link
Interrupted contiguous VC3-xc
Mismatched encapsulation protocol
TU_AIS_VC3 happens in the opposite node
VC-Trunk bandwidth decreases

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page71

Ethernet Unit (Cont.)

Common performance events of Ethernet unit

Performance
name

Performance meaning

DropOv

Number of packet losses is over upper alarm threshold

DropUd

Number of packet losses is under lower alarm threshold

RxBadOctOv

Number of the bytes of bad packets received is over upper alarm


threshold

RxBadOctUd

Number of the bytes of bad packets received is under lower alarm


threshold

TxBadOctOv

Number of the bytes of bad packets transmitted is over upper


alarm threshold

TxBadOctUd

Number of the bytes of bad packets transmitted is under lower


alarm threshold

ColOv

Number of detected conflicts is over upper alarm threshold

ColUd

Number of detected conflicts is under lower alarm threshold

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page72

ATM Unit

Boards Description

Board

ADL4

ADQ1

Full name

Interface type

1 x STM-4 ATM processing with

S-4.1, L-4.1, Ve-4.1, L-

interface board

4.2

4 x STM-1 ATM processing with

Ie-1, S-1.1, Ve-1.2, L-

interface board

1.2, L-1.1

Connecto
r type

LC
IDL4

IDQ1

1 x STM-4 ATM/IMA processing with

S-4.1, L-4.1, L-4.2, Ve-

interface board

4.2

4 x STM-1 ATM/IMA processing with

Ie-1, S-1.1, L-1.2, Ve-

interface board

1.2, L-1.1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page73

ATM Unit (Cont.)


ADL4

ADQ1

STAT
ACT
PROG
SRV

CLASS 1

I DQ1

I DL4
STAT
ACT
PROG
SRV

STAT
ACT
PROG
SRV
CLASS 1

STAT
ACT
PROG
SRV

CLASS 1

CLASS 1

LASER

LASER

LASER

LASER

PRODUCT

PRODUCT

PRODUCT

PRODUCT

O U TI N1 1

O U T IN
1 1

O U T IN
1 1

O U T IN
1 1

O U TI 2N 2

O U T I2N 2

CLASS 1
LASER
PRODUCT

O U TI 3N 3

O U T I3N 3
ADQ 1

O U T I 4N 4

O U T 4IN 4

ADL4

IDL4

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

I DQ1

Page74

S
F
P
C
O
N
N
E
C
T
O
R

ATM Unit (Cont.)

Slot available
Slot available
Board
Name

OSN

OSN

OSN

1500A

1500B

2500

ADL4
ADQ1
12, 13
IDL4
IDQ1

(11),
12, 13

OSN 3500
40G

80G

200G

6 ~ 8,
11 ~ 13

1 ~ 8, 11 ~ 17

1 ~ 8,
11 ~ 16

1 ~ 8,11 ~ 17

7, 8, 1113

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page75

ATM Unit (Cont.)

Function of ADQ1

Collect Alarm
and
performance

4
X
ATM

Send to Cross-connect
unit

ATM

SCC
o
t
d
Sen

Mappe
r
VC-12, VC-4,
VC-4-Xv

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

8
X
VC4

Page76

ATM Unit (Cont.)

Features of ADQ1

Supports CBR, rt-VBR, nrt-VBR and UBR

Supports QoS

ATM switching capability: 1.25 Gbit/s

Max. uplink bandwidth: 8 VC-4, or 12 VC-3 + 4 VC-4

E3 traffic can be received from PDH board

Supports ATM multicast connection

Supports VP-Ring and VC-Ring

Uni-directional/bidirectional 1+1 and 1:1 board protection

Supports inloop and outloop

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page77

ATM Unit (Cont.)

Common alarms of ATM unit

Alarm
level

Color

Alarm
name
VPAIS

Alarm reason
More critical alarms e.g. R_LOS happens.

Critica

The faulty ATM board

More critical alarms e.g. R_LOS happens.

VCAIS

Major

The faulty ATM board

VPRDI

The VPAIS is reported on the opposite node ATM board

VCRDI

The VCAIS is reported on the opposite node ATM board

LCD

The cell heads are lost

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page78

ATM Unit (Cont.)

Common performance of ATM

unit
Performance name

Performance meaning

VC3BBE

VC3 block of background error

VC3ES

VC3 errored second

VC3FEBBE

VC3 far end block of background error

VC3FEES

VC3 far end errored second

ATM_INGCELL

Number of input cells in ATM link

ATM_EGCELL

Number of output cells in ATM link

ATM_CORRECTED_HCSERR

Number of corrected cells with HCS error at ATM interface

ATM_UNCORRECTED_HCSER
R

Number of uncorrected cells with HCS error at ATM


interface

ATM_RECV_CELL

Number of cells ATM interface received

ATM_RECV_IDLECELL

Number of idle cells ATM interface received

ATM_TRAN_CELL

Number of cells ATM interface transmitted

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page79

MST Unit

Board description

Board Name

Description
4 x multi-service transparent

MST4

transmission processing with


interface board

Slot available
Slot available
Board
Name

MST4

OSN

OSN

1500A

1500B

12, 13

11 ~ 13

OSN 2500

OSN 3500

5 ~ 8, 11 ~
13

1 ~ 8, 11 ~
16 (17)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page80

MST Unit

Service Types

Service type

Rate

Remarks

GE

1000 Mbit/s

Data service

FC50

531.25 Mbit/s

Storage Area Network (SAN)

FC100/FICON

1062.5 Mbit/s

SAN service

FC200

2125 Mbit/s

SAN service

ESCON

200 Mbit/s

SAN service

DVB-ASI

270 Mbit/s

Video service

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page81

MST Unit (Cont.)

M ST 4
STAT
ACT
PROG
SRV

O U T 1IN 1
O U T 2IN 2
O U T 3IN 3
O U T 4IN 4
M ST 4

S
F
P
C
O
N
N
E
C
T
O
R

Features of MST unit

Total uplink bandwidth 2.5G

Supports GFP-T encapsulation

Inloop and outloop function at the client

side

Distance extension function for ports 1 and

SFP Modules

Services

SDH side

Client side

FC100

3000km

40km

FC200

1500km

20km

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page82

MST Unit (Cont.)

Function

Collect Alarm
and
performance

Send to Cross-connect
unit

Multi-Services

SAN

C
o SC
t
d
Sen

GFP-T
VC-4-4c/8c/16c

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

16
X
VC4

Page83

Core Unit -OSN 1500/2500

The CXL1/CXL4/CXL16 is the core unit used in OptiX OSN 1500/2500.


Cross-connect Unit

Timing Unit

SCC Unit

Line Unit

Location in OptiX OSN 1500A and


OptiX OSN 1500B: slot 4 and 5

Location in OptiX OSN 2500: slot 4


and 5

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page84

Cross-Connect Unit
SDH unit

PDH unit

Data unit
Collect Alarm

to S
d
n
Se

High-order cross-connect
matrix

Low-order cross-connect
matrix

MultiGranularity:
VC12/VC3/VC4/V
C-4-xc

Flexible service cross-connect,


loopback, multicast and broadcast

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page85

CC

Cross-Connect Unit OSN1500/2500


CX L 1 6

CX L 4

CXL1

STAT
ACTX
ACTC
PROG
SRVX
SRVL
SYNC
ALMC

STAT
ACTX
ACTC
PROG
SRVX
SRVL
SYNC
ALMC

STAT
ACTX
ACTC
PROG
SRVX
SRVL
SYNC
ALMC

CLASS 1
LASER
PRODUCT

CLASS 1
LASER
PRODUCT

CLASS 1
LASER
PRODUCT

Indicato
r

Color

O U TIN

O U TIN

O U TIN

Board works normally


STAT

RESET

RESET

RESET

ALM CUT

ALM CUT

ALM CUT

Description

Board hardware fails


Board is powered off
Cross-connect unit is in active

ACTX

status
Cross-connect unit is in standby
status

CX L 1 6

CX L 4

CX L 1

Logical unit
GXCL (5G)
EXCL (20G)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page86

Cross-connect Unit OSN3500

The cross-connect unit is inserted in slot 9 or 10 of OptiX OSN


3500.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page87

Cross-Connect Unit OSN3500

OSN 3500

Cross-connect

Max

High-order

Low-order

For Extension

and timing

access

cross-connect

cross-connect

sub-rack HO

board

capacity

capacity

capacity

XC capacity

GXCS

35G

35G

5G

EXCS

58.75G

75G

5G

UXCSA

58.75G

60G

20G

UXCSB

60G

60G

20G

1.25G

SXCSA

155G

180G

20G

SXCSB

156.25G

180G

20G

1.25G

XCE

1.25G

1.25G

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page88

Cross-Connect and Timing Unit


OSN3500
GXCSA

EXCSA

UXCSA

STAT
ACT
PROG
SRV
SYNC

STAT
ACT
PROG
SRV
SYNC

STAT
ACT
PROG
SRV
SYNC

GXCSA

EXCSA

UXCSA

UXCSB
STAT
ACT
PROG
SRV
SYNC

XCE
STAT
ACT
PROG
SRV
SYNC

EXA

EXA

EXB

EXB

UXCSB

XCE

SXCSA
STAT
ACT
PROG
SRV
SYNC

SXCSB
STAT
ACT
PROG
SRV
SYNC

EXA

EXB

SXCSA

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

SXCSB

Page89

Cross-connect Unit OSN3500


UXCSB

XCE

STAT
ACT
PROG
SRV
SYNC

STAT
ACT
PROG
SRV
SYNC

EXA

EXB

UXCSB

DB26 Connector:
To connect the
main sub-rack and
the extension subrack together.

UXCSB/SXCSB
EXA

EXA

EXB

EXB

EXA

EXA

EXB

EXB

EXA

EXB

XCE

XCE

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page90

Cross-Connect Unit
10G line unit

10G line unit

Crossconnect

2.5G line unit

PDH unit

Crossconnect

2.5G line unit

Standby
PDH unit

Active
Ethernet unit

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Ethernet unit

Page91

Cross-Connect Unit (Cont.)

Features

Support SNCP protection for VC-4-4C, VC-4-8C, VC-4-16C,


VC-4-64C, VC-4, VC-12, VC-3

Support 1+1 hot backup

Active/standby Restoration

Inserted in slots 9 (Active) and 10 (Standby)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page92

Timing Unit OSN1500/2500

Indicator

Color

Description
Clock works in Normal mode

SYNC
Clock works in hold-over or free-run mode

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page93

Timing Unit OSN3500

Indicato

Colo

ACT
SYNC

Description
ON Board is active/OFF Board is standby
Clock works in Normal mode
Clock works in hold-over or free-run mode

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page94

Timing Unit

Features

Process traced clock signal from Line, Tributary and external clock

Process 2 x Input/ 2 x Output 2Mbits/2Mhz external clock signals

Support Normal (Trace), Hold-over and Free-run clock status

working modes

Process SSM byte to realize clock protection switching

Non-synchronization status message (SSM) mode

Standard SSM mode

Extended SSM mode

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page95

Cross-Connection & Timing Unit

Common alarms of Cross-Connect and Timing

unit
Alarm
level

Color

Alarm name
BUS_ERR

Major

Minor

Chip of the cross-connect board is damaged


Damaged backplane bus

APS_INDI

MSP switching happens

TEMP_OVER

Ambient temperature is too high.

W_OFFLINE

Ejector lever on the front panel is rotated to the open


position.

EXT_SYNC_LOS

Physical interface signal of the external clock source is lost.

CLOCK_ENTER_NO
_TRACE_MODE

Clock working mode changes from locked into holdover or


free-run.

APS_FAIL
Warning

Alarm reason

Multiplex section protection switching fails.


MS node information is lost or set incorrectly

SWITCH_DISABLE

Board switching is disabled

OTH_BD_STATUS

Another board pulled out or plugged in

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page96

System Control & Communication


Unit

SDH unit
Commands

PDH unit
Other unit

Collect Alarm and


performance

Cross-connect unit

NMS

DCC

Other NE

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page97

System Control & Communication


Unit OSN1500/2500
CXL1
STAT
ACTX
ACTC
PROG
SRVX
SRVL
SYNC
ALMC

Active SCC unit ACTC

Standby SCC unit ACTC

CLASS 1
LASER
PRODUCT

To warm reset board, press RESET


O U TIN

Reset board

To cut buzzer temporarily, press ALMC for 1 second


)

To cut buzzer permanently, press ALMC for 3 seconds


)

To re-enable buzzer, press ALMC for 1 second


)
Logical unit
SCC
GSCC (with ASON)

RESET
ALM CUT

Alarm cut
switch
(short and
long press)

CXL1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page98

System Control & Communication


Unit OSN3500 (Cont.)
Indicato
SCC
STAT
ACT
PROG
SRV
PWRA
PWRB
PWRC
ALMC

GSCC

Reset

STAT
ACT
PROG
SRV
PWRA
PWRB
PWRC
ALMC

Color

Description
The 48 V power supply A is normal.

PWRA

The 48 V power supply A is faulty (lost or


failed).
The 48 V power supply B is normal.

RESET

PWRB

The 48 V power supply B is faulty (lost or


failed).

ALM CUT

PWRC
RESET

Alarm cut

SCC

ALMC

ALM CUT

GSCC

The 3.3 V protection power is normal.


The 3.3 V protection power is lost.
Currently in permanent alarm cut-off status.

Give audible warning upon critical alarm.


To warm reset board, press RESET
To cut buzzer temporarily, press ALMC for 1 second

To cut buzzer permanently, press ALMC for 3 seconds

To re-enable buzzer, press ALMC for 1 second

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page99

System Control & Communication


Unit (Cont.)

Functions

Service configuration, grooming and monitoring

Collects alarm and performance events

Supports NE ID setting by software

1+1 hot backup

Extended ECC

Controls cabinet indicators and fans

3 Housekeeping alarm inputs and 1 alarm outputs

Supports ASON intelligent function

OSN3500: Inserted in slot 18 (Active) and/or Slot 17 (Standby)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page100

System Control & Communication


Unit (Cont.)

Extended ECC function

NMS

Ring A

Ring B

Ethernet
port

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

L< 50m

Page101

Ethernet
port

System Control & Communication


Unit (Cont.)

Four databases on the SCC

Issued data

MDB
Automatically saves the current
data in dynamic RAM.
If power fails, the data in MDB will
be lost.

MDB
DRDB
Automatically saves the
successfully verified data.
If power fails, the data in
DRDB will be lost.

FDB0, FDB1
Manually or periodically
saves the data. Enduringly
saves data and does not
need battery.

verify

Fail

NE in installing
status

Success

DRDB

Boards in
running status

Save manually or
periodically every 30 mins

FDB0
FDB1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page102

System Control & Communication


Unit (Cont.)

Common alarms of SCC unit

Alarm

Colo

level

Critical

Alarm name

Alarm reason

NESTATE_INSTALL

NE is in the installing state.

MSSW_DIFFERENT
WRG_BD_TYPE
Major

NESF_LOST

Software in the master and slave SCC are


mismatched
Inserted board and the configured board are
mismatched
Host software is lost.
Faulty power resource, e.g. the 3.3V power

POWER_ABNORMA

module of the SCC or AUX, and the 3.3V

backup power module, and 2 channels of


48V

POWER_FAIL

Too low battery voltage on the SCC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page103

Auxiliary Unit

Board Description

Board

Function

Remark

AUX

Auxiliary Interface Board

PIU

Power Interface Board

EOW

Orderwire Board

SAP

System Auxiliary Process

Only for OptiX OSN 2500

SEI

System Extended Interface

Only for OptiX OSN 2500

UPM

Uninterruptible Power Modules

External

AMU

Auxiliary Monitoring Unit

Only for OptiX OSN 1500

BA2

Booster Amplifier Board

BPA

Pre-amplifier Board

COA

Case-based Optical Amplifier

External

DCU

Dispersion Compensation Board

Only for OptiX OSN


3500/7500

FAN/FANA

Fan unit

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page104

Auxiliary Unit AUX&AMU (OSN 1500)


AUX

AUX

ETH: T2000 Interface

ETH

COM

CLK

ALM

OAM/F&f

The AUX board used in


OptiX OSN 1500 is

COM: Commissioning Interface


CLK : 120 ohms external clock input/output interface
ALM: House-keeping alarm input/output interface
OAM/F&f: NM and management serial interface

inserted in slot 10.

AMU

The AMU board used in


OptiX OSN 1500 is
inserted in slot 9.

STA T
PR OG

AM U

PHONE: Orderwire Interface

PHONE

S1

S2

LAMP1

LAMP2

S1&S2: Broadcast data channels interfaces


LAMP1&LAMP2: Provide drive current for cabinet indicators

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page105

Auxiliary Unit -SAP&SEI (OSN


2500)
ALMO1/2: Alarm output
ALMI1/2: 8 x Environment alarm input

LAMP1/2: Cabinet indicator output


OAM: X.25 OAM
F1: Co-directional data 64 Kbit/s
S1 ~ S4: Serial 1 ~ 4 broadcast data

SAP is the system auxiliary


processing board. It is inserted
in slot 14 in OptiX OSN 2500.
SEI provides various auxiliary
interfaces and management
interfaces. It is on top of the
sub-rack.

Q
1SAP
STAT
PROG
PWRA
PWRB
PWRC

F&f: LCT
PHONE: Orderwire
CLK1/2: 120 Ext clock input/output 1/2
V1/2: NNI Audio/Signaling
ALMO1 ALMO2

LAMP
1

LAMP
2

OA
M

F1

F&
f

PHONE

CLK1

CLK2

CO
M

CLKO1 CLKO2 CLKI1 CLKI2

ALMI1

ALMI2

S1

S2

S3

S4

V1

V2

E
TH

CLKO1/2: 75 Ext clock output 1/2


CLKI1/2: 75 Ext clock input 1/2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Q
1SAP

Page106

Auxiliary Unit -AUX (OSN 3500)

The AUX board used in OptiX OSN 3500 provides


system auxiliary interfaces. It is inserted in slot 37.
ALMI1 ~ 4: Environment alarm input
S1 ~ S4: Serial 1 ~ 4 broadcast data

75 Ext clock input 1/2


75 Ext clock output 1/2
Board status
CLKI2

CLK2

ETH

COM

EXT

ALMP1

ALMP2

ALMO1

ALMO2

ALMI1

ALMI2

ALMI3

ALMI4

CLK1

REV

F&f

F1

PHONE

V1

V2

OAM

S1

S2

S3

S4

CLKO1 CLKO2

NIAUX

STAT

NIAUX

CLKI1

CLK1/2: 120 Ext clock input/output 1/2


ETH: T2000
COM: Commissioning
EXT: Extended sub-rack
REV: F&f: LCT
F1: Co-directional data 64 Kbit/s

ALMP1/2: Cabinet indicator output


ALM01/2: Alarm output
Phone: Orderwire
V1/2: NNI Audio/Signaling
OAM: X.25 OAM

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page107

P IUA

NEG(-)

RTN(+)

Switch

CLK IN
PWR

NEG(-)

Interfac
e

75 synchronization
input/output (SMB) interface

PWR

48 V power access
interface

PWS

50 W power output
interface, supplying power
for COA or HUB

RTN(+) CLK OUT

R1PIU is applicable to the


OptiX OSN 1500B and seated
in slots 18 and 19

Description

CLK
IN/OUT

R 1 P IU

POW ER

PWS

R1PIUA is applicable to the


OptiX OSN 1500A and seated
in slots 1 and 11

R 1 P IU

POWER

P IUA

Auxiliary Unit -PIU

Indicat
or
Power
indicator

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Status

Description

On, green

Power input is
normal

Off

No power input or
power failure

Page108

Auxiliary Unit -PIU


PIU

NIPIU

PWS

RTN(+)

Used in OSN
3500

Inserted in slot
27 and 28

PWR
NEG(-)
PWR

Used in OSN 2500

Inserted in slot 22 and 25

PS1

PS2

Interface

Description

PWS

50 W power output interface,


supplying power for COA or
HUB

NIPI U

PWR

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

48 V power access interface

Page109

Auxiliary Unit PIU (Cont.)

Functions

Access power 38.4 V ~ 57.6 V DC or -48 V ~ -72 V

Lightning protection

Enhanced electro magnetic compatibility (EMC) by filtering and


shielding the power supply from EMI.

Provide 2 x 50 W power interfaces for external devices such as COA


and HUB.

1+1 hot backup protection

Supply power to FAN boards

Detect input power failures

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page110

Auxiliary Unit -EOW (OSN 1500)

The EOW board is the orderwire board used in OptiX OSN 1500,
which is inserted in slot 9 of the sub-rack.

The AMU/EOW or some SDH/PDH unit can be inserted in slot 9 of


the sub-rack. Insert different boards due to different demands.

PHONE: Orderwire interface

EOW

EOW

STAT
PROG

S1~S4: 4 broadcast data channel interfaces

PHONE

S1

S2

S3

S4

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page111

Auxiliary Unit UPM (OSN1500)

Functions of UPM

Convert AC 110/220V to DC -48V

Height 1U

Consists of converter and battery

Power feedback is 2 x 270W

Can be installed in 19 inch cabinet

Display CAU in T2000 NMS

Capacity of the battery is 40Ah

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page112

Auxiliary Unit UPM (OSN1500)


4
BAT

! CAUTION

BAT-

DO NOT INVERT POLARITY


BAT+
48V+
48VLOAD1

LOAD2

5
AC100~240

6
RUN

ALM Vout

ALM

ALM Vout
RS232

1: AC input
4: Battery input

2: AC-DC Converter, ventilation


5,6: Power feed interface

3: Communication interface

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page113

Amplifier Unit -BA2&BPA&COA


Board

Connecto
r

Description

BA2

Booster Amplifier Board

LC

BPA

Pre-amplifier Board

LC

COA

Case-based Optical Amplifier

LC

Slot available
Board

COA
BA2
BPA

OSN

OSN

OSN

1500A

1500B

2500

OSN 3500

External
12, 13

11 ~ 13

5 ~ 8, 11
~ 13

1 ~ 8, 11
~ 16 (17)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page114

Auxiliary Unit BA2


Input optical power
-6 ~ +3 dBm

Tx

Output optical power


+ 13 ~ + 15 dBm
+ 15 ~ +17 dBm

Rx

BA

Input/Output optical power detection

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page115

Auxiliary Unit BA2 (Cont.)


BA2
STA T
ACT
PR OG
SR V

O U T 1IN 1

1/ 2 BA
modules
LC connector

O U T 2IN 2

Specifications

IN1/2 (dBm)
CLASS 1
LASER
PRODUCT

6 ~ +3

BA2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Output 1

Output 2

(dbm)

(dbm)

+13 ~ +15

+15 ~ +17

+13 ~ +15

+13 ~ +15

+15 ~ +17

+15 ~ +17

+13 ~ +15

+15 ~ +17

Page116

Auxiliary Unit BA2 (Cont.)

Function

2 channel power amplification

Used on TX side

Fixed output optical power

Used for 1530 ~ 1565 nm signals

Reports laser performance parameter

ALS function

Automatic control of laser temperature and optical power of

the EDFA module

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page117

Auxiliary Unit BPA


Receiver sensitivity
-38 dBm

Gain
22 dB

Tx

Rx

PA

Detects the input/output optical power

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page118

Auxiliary Unit BPA (Cont.)


BPA
STA T
ACT
PR OG
SR V

P O U T P IN

Port 2:
PA module
LC connector

Specifications

B O U T B IN

Port 1:
BA module
LC connector

BIN (dBm)

BOUT (dBm)

-6 ~ +3
-

PIN

POUT

(dBm)

(dBm)

+13 ~ +15

-10 ~ -37

+11 ~ -16

+15 ~ +17

CLASS 1
LASER
PRODUCT

BPA

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page119

Auxiliary Unit BPA (Cont.)

Function

1-channel power amplification

1-channel pre-amplification

Fixed output optical power

Improving the receiver sensitivity to 38 dBm

BA used for 1530 ~ 1565 nm signals

PA used for 1550.12 nm signals

ALS function

Reports performance parameter

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page120

Auxiliary Unit COA


9

1. ID DIP switch
5. RS232-2
9. OUT output optical

10

2. Running

3. Alarm

indicator

indicator

6. MONITOR-1

7. MONITOR-2

10. Power switch

11. 48 V power interface

Copyright
2006 Huawei Technologies Co., Ltd. All rights reserved.
port

11

4. RS232-1
8. IN input optical
port

Page121

Auxiliary Unit COA (Cont.)

External installation

Types

61COA

Only one EDFA module

Can work as BA (+14 dBm or +17dBm), PA (with the receiver


sensitivity of 38 dBm ) or LA

62COA

Raman amplifier with good noise performance

used in the RX (with the receiver sensitivity of 39 dBm)

Ultra long hop transmission for a single span (>170 km )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page122

Amplifier Unit

Common alarms of Amplifier unit


Alarm level

Critical

Color

Alarm name

Alarm reason

IN_PWR_FAIL

No input signal

IN_PWR_HIGH

Input power is too high

IN_PWR_LOW

Input power is too low

OUT_PWR_ABN

Abnormal output power

PUM_COOL_ALARM

Faulty EDFA module

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page123

Amplifier Unit

Common performance of Amplifier unit

Performance name

Performance meaning

EDRPLAVG

Current value of input optical power

EDRPLMAX

Maximum value of input optical power

EDRPLMIN

Minimum value of input optical power

EDTMPCUR

Current value of environment temperature

EDTMPMAX

Maximum value of environment temperature

EDTMPMIN

Minimum value of environment temperature

EDTPLCUR

Current value of output optical power

EDTPLMAX

Maximum value of output optical power

EDTPLMIN

Minimum value of output optical power

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page124

Auxiliary Unit -DCU


DC U

Board
DCU

Description

Connector

Dispersion compensation
board

LC

1/2 DCM
LC connector
O U TI N1 1
O U T I2N 2

Slot available
Board

DCU

OSN

OSN

OSN

OSN

OSN

1500A

1500B

2500

3500

7500

1 ~ 8, 11
~ 17

1-8, 11-18,
26-31
DC U

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page125

Auxiliary Unit DCU (Cont.)


Compensates
Compensates
60km or 80km
60km or 80km

Tx

BA

DCU
DCU

PA

Insertion loss 7 dB
Used for 10G signals
Inserted in slots 1 ~ 8, 11 ~ 16
Works with BA and PA

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page126

Rx

Auxiliary Unit -FAN

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page127

Auxiliary Unit -FAN (Cont.)

Function

Support hot swapping

Intelligent speed adjustment


Indicator

Color

Description
Fan operates normally.

STAT

Fan, fan power board or FANA is abnormal.


Fan is turned off due to low temperature.

Alarm level
Major

Color

Alarm name
FAN_FAIL

Alarm reason
Faulty fan
Fan is power off

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page128

Questions

Please list different boards in OptiX OSN 1500/2500/3500.


SDH Boards
PDH Boards
Ethernet Boards
ATM Boards
MST Boards
WDM Boards
Cross-connect and
System Control Boards
Auxiliary Unit

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page129

Contents
1.

Product Introduction

2.

Cabinet, Sub-rack

3.

Boards

4.

Common Network Elements and Configuration

5.

Features

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page130

Contents
4. Common network elements
4.1 Terminal multiplexer (TM)
4.2 Add and drop multiplexer (ADM)
4.3 Multi-add and drop multiplexer (MADM)
4.4 Regenerator (REG)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page131

Terminal multiplexer

TM

Low rate signals


PDH: E1/T1, E3/T3, E4
SDH: STM-1e
DATA: FE, GE, ATM, ...

High rate signals


SDH: STM1/4/16/64

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page132

Terminal multiplexer (Cont.)

TM functions
Add and drop tributary signals

PDH signals: E1/T1, E3/T3, E4

SDH signal: STM-1e

Cross-connect tributary & line unit signals

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page133

Terminal multiplexer (Cont.)

TM configuration

Tributary unit
16 x E1s

Line unit

STM-16

PL3A

Slot 20 CXL16

Tributary unit

3 x E3s

FAN

Slot 1 PIU

CXL16

3 x E3s

32 x E1s

PIU

Line unit

STM-16

Slot 11PL1

Slot 6

Slot 12

Slot 7

Slot 13

Slot 8

Slot 4

EOW

Slot 9

Slot 5

AUX

Slot 10

Slot 1 PIU

Slot 11 L75S

Slot 6

Slot 2PD1

Slot 12 L75S

Slot 7

PL3A

Slot 13

Slot 8

CXL16

Slot 4EOW

Slot 9

Slot 5 AUX

Slot 10

PIU
FAN

Slot 20 CXL16

OptiX OSN 1500A


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page134

Terminal multiplexer (Cont.)

TM configuration

Tributary unit
63 x E1s
3 x E3s

Line unit

D75S
D75S
C34S

STM-16

Slot14
PIU
Slot15
Slot16
PIU
Slot 17

Slot19

Slot 11

Slot 6

PQ1

Slot 12

Slot 7

PL3

Slot 13

Slot8

CXL16

Slot 4EOW

Slot 9

CXL16

Slot 5 AUX

Slot 10

Slot 20

FAN

Slot18

OptiX OSN 1500B

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page135

Terminal multiplexer (Cont.)

TM configuration

Tributary unit
63 x E1s
4 x E3s

D
7
5
S

D
7
5
S

D
3
4
S

S
l
o
t
1

S
l
o
t
2

S
l
o
t
3

P
Q
1

P
D
3

S
l
o
t
6

S
l
o
t
7

Line unit

C
X
L
1
6

C
X
L
1
6

S
l
o
t
9

S
l
o
t
1
0

S
A
P

STM-16
S
l
o
t
4

S
l
o
t
5

S
l
o
t
8

S
l
o
t
1
1

S
l
o
t
1
2

S
l
o
t
1
3

S
l
o
t
1
4

S
l
o
t
1
5

S
l
o
t
1
6

S
l
o
t
1
7

S
l
o
t
1
8

Fiber routing panel


SLOT 22
PIU

SLOT 23
FAN

SLOT 24
FAN

OptiX OSN 2500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page136

SLOT 25
PIU

Terminal multiplexer (Cont.)

D
3
4
S

TM configuration

Tributary unit
126 x E1s

Line unit

STM-64

S
l
o
t
1
9

S
l
o
t
2
0

6 x E3s

S
l
o
t
2
1

D
7
5
S
S
l
o
t
2
2

S
l
o
t
2
3

D
7
5
S

D
7
5
S

S
l
o
t
2
4

S
l
o
t
2
5

D
7
5
S
S
l
o
t
2
6

A
U
X
P
I
U

P
I
U

FAN

S
l
o
t
1

S
l
o
t
2

S S S
l l l
o o o
t t t
3 4 5

S
l
o
t
3
0

S
l
o
t
3
1

S
l
o
t
3
2

S
l
o
t
3
3

S
l
o
t
3
4

FAN

P P P
D Q Q
3 1 1

2 x STM-1e

S
l
o
t
2
9

S
l
o
t
6

OptiX OSN 3500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

S
l
o
t
7

S
L
6
4

G
X
C
S

G
X
C
S

S
l
o
t
8

S
l
o
t
9

S
l
o
t
1
0

S
l
o
t
3
6

S
l
o
t
3
7

FAN
S
E
P
1
S
l
o
t
1
2

Fiber Routing

Page137

S
l
o
t
3
5

S
l
o
t
1
2

S
l
o
t
1
3

S
l
o
t
1
4

S
l
o
t
1
5

G G
S S
C C
C C
S
l
o
t
1
6

S
l
o
t
1
7

S
l
o
t
1
8

Add and drop multiplexer

ADM

High rate signals


SDH: STM1/4/16/64

Low rate signals


PDH: E1/T1, E3/T3, E4
SDH: STM-1e
DATA: FE, GE, ATM, ...
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page138

Add and drop multiplexer (Cont.)

ADM functions
Add and drop tributary signals

PDH signals: E1/T1, E3/T3, E4

SDH signal: STM-1e

Cross-connect tributary & line unit signals

Cross-connect line units pass-through signals

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page139

Add and drop multiplexer (Cont.)

ADM configuration

Tributary unit
16 x E1s

Line unit

Slot 1 PIU

PL3A

Slot 11PL1

Slot 7

Slot 13

Slot 8

Slot 20 CXL16

Line unit

STM-16

Slot 6

Slot 12

CXL16

Tributary unit

3 x E3s

FAN

STM-16

3 x E3s

32 x E1s

PIU

Slot 4 EOW

Slot 9

Slot 5 AUX

Slot 10

Slot 1 PIU

Slot 11 L75S

Slot 6

Slot 2PD1

Slot 12 L75S

Slot 7

PL3A

Slot 13

Slot 8

CXL16

Slot 4EOW

Slot 9

Slot 5 AUX

Slot 10

PIU
FAN

Slot 20 CXL16

OptiX OSN 1500A


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page140

Add and drop multiplexer (Cont.)

ADM configuration

Tributary unit
63 x E1s
3 x E3s

Line unit

D75S
D75S
C34S

STM-16

Slot14
PIU
Slot15
Slot16
PIU
Slot 17

Slot19

Slot 11

Slot 6

PQ1

Slot 12

Slot 7

PL3

Slot 13

Slot8

CXL16

Slot 4EOW

Slot 9

CXL16

Slot 5AUX

Slot 10

Slot 20

FAN

Slot18

OptiX OSN 1500B

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page141

Add and drop multiplexer (Cont.)

ADM configuration

Tributary unit
63 x E1s
4 x E3s

D
7
5
S

D
7
5
S

D
3
4
S

S
l
o
t
1

S
l
o
t
2

S
l
o
t
3

P
Q
1

P
D
3

S
l
o
t
6

S
l
o
t
7

Line unit

C
X
L
1
6

C
X
L
1
6

S
l
o
t
9

S
l
o
t
1
0

S
A
P

STM-16
S
l
o
t
4

S
l
o
t
5

S
l
o
t
8

S
l
o
t
1
1

S
l
o
t
1
2

S
l
o
t
1
3

S
l
o
t
1
4

S
l
o
t
1
5

S
l
o
t
1
6

S
l
o
t
1
7

S
l
o
t
1
8

Fiber routing panel


SLOT 22
PIU

SLOT 23
FAN

SLOT 24
FAN

OptiX OSN 2500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page142

SLOT 25
PIU

Add and drop multiplexer (Cont.)

D
3
4
S

ADM configuration

Tributary unit
126 x E1s

Line unit

STM-64

S
l
o
t
1
9

S
l
o
t
2
0

6 x E3s

S
l
o
t
2
1

D
7
5
S
S
l
o
t
2
2

S
l
o
t
2
3

D
7
5
S

D
7
5
S

S
l
o
t
2
4

S
l
o
t
2
5

D
7
5
S
S
l
o
t
2
6

A
U
X
P
I
U

P
I
U

FAN

S
l
o
t
1

S
l
o
t
2

S S S
l l l
o o o
t t t
3 4 5

S
l
o
t
3
0

S
l
o
t
3
1

S
l
o
t
3
2

S
l
o
t
3
3

S
l
o
t
3
4

FAN

P P P
D Q Q
3 1 1

2 x STM-1e

S
l
o
t
2
9

S
l
o
t
6

OptiX OSN 3500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

S
l
o
t
7

S
l
o
t
3
6

S
l
o
t
3
7

FAN

S
L
6
4

G
X
C
S

G
X
C
S

S
L
6
4

S
l
o
t
8

S
l
o
t
9

S
l
o
t
1
0

S
l
o
t
1
1

Fiber Routing

Page143

S
l
o
t
3
5

S
E
P
1
S
l
o
t
1
2

S
l
o
t
1
3

S
l
o
t
1
4

S
l
o
t
1
5

G G
S S
C C
C C
S
l
o
t
1
6

S
l
o
t
1
7

S
l
o
t
1
8

Multi-add and drop multiplexer

MADM

High rate signals


SDH: STM-1/4/16/64

Low rate signals


PDH: E1/T1, E3/T3, E4
SDH: STM-1e
DATA: FE, GE, ATM, ...
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page144

Multi-add and drop multiplexer


(Cont.)
MADM functions

Add and drop tributary signals

PDH signals: E1/T1, E3/T3, E4

SDH signal: STM-1e

Cross-connect tributary & line unit signals

Cross-connect line units pass-through signals

Used as intermediate node for topologies of different


optical signal rates

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page145

Multi-add and drop multiplexer


(Cont.)
MADM configuration

Tributary unit

Line unit

16 x E1s

STM-16

3 x E3s

STM-4

Tributary unit
32 x E1s
3 x E3s

Line unit

STM-16
STM-4

PIU
FAN

Slot 1 PIU

PL3A

Slot 11PL1
Slot 12

SLQ4

Slot 4

Slot 20 CXL16

PIU
FAN

Slot 7

Slot 13

CXL16

Slot 6

Slot 8
EOW

Slot 5 AUX

Slot 9
Slot 10

Slot 1 PIU

Slot 11 L75S

Slot 6

Slot 2 PD1

Slot 12

Slot 7

PL3A

Slot 13
R1SLD4

Slot 8

CXL16

Slot 4EOW

Slot 9

Slot 5AUX

Slot 10

Slot 20 CXL16

OptiX OSN 1500A


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page146

Multi-add and drop multiplexer


(Cont.)
MADM configuration

Tributary unit

Line unit

63 x E1s

STM-16

3 x E3s

STM-4

D75S
D75S
C34S

Slot14
PIU
Slot15
Slot16
PIU
Slot 17

Slot19

Slot 11

Slot 6

PQ1

Slot 12

Slot 7

PL3

Slot 13
R1SLD4

Slot8

CXL16

Slot 4EOW

Slot 9

CXL16

Slot 5AUX

Slot 10

Slot 20

FAN

Slot18

OptiX OSN 1500B

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page147

Multi-add and drop multiplexer


(Cont.)
MADM configuration

Tributary unit

D
7
5
S

D
7
5
S

D
3
4
S

S
l
o
t
1

S
l
o
t
2

S
l
o
t
3

P
Q
1

P
D
3

S
L
D
4

C
X
L
1
6

C
X
L
1
6

S
l
o
t
6

S
l
o
t
7

S
l
o
t
8

S
l
o
t
9

S
l
o
t
1
0

Line unit

63 x E1s

STM-16

4 x E3s

STM-4

S
l
o
t
4

S
l
o
t
5

S
A
P

S
l
o
t
1
1

S
l
o
t
1
2

S
l
o
t
1
3

S
l
o
t
1
4

S
l
o
t
1
5

S
l
o
t
1
6

S
l
o
t
1
7

S
l
o
t
1
8

Fiber routing panel


SLOT 22
PIU

SLOT 23
FAN

SLOT 24
FAN

OptiX OSN 2500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page148

SLOT 25
PIU

Multi-add and drop multiplexer


(Cont.)
MADM configuration
D
3
4
S

Tributary unit

Line unit

100 x E1s

STM-64

6 x E3s

STM-16

S
l
o
t
1
9

S
l
o
t
2
0

S
l
o
t
2
1

D
7
5
S

S
l
o
t
2
2

S
l
o
t
2
3

D
7
5
S
S
l
o
t
2
4

D
7
5
S
S
l
o
t
2
5

D
7
5
S
S
l
o
t
2
6

P
I
U

P
I
U

FAN
P P P S
D Q Q L
3 1 1 D
4

2 x STM-1e STM-4
S
l
o
t
1

S
l
o
t
2

S
l
o
t
2
9

S
l
o
t
3
0

S
l
o
t
3
3

S
l
o
t
3
4

G
X
C
S

S
L
6
4

S S S S S S
l l l l l l
o o o o o o
t t t t t t
3 4 5 6 7 8

S
l
o
t
9

S
l
o
t
1
0

S
l
o
t
1
2

Fiber Routing

Page149

S
l
o
t
3
5

S
l
o
t
3
6

S
l
o
t
3
7

FAN

G
X
C
S

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

S
l
o
t
3
2

FAN
S S
L L
1 6
6 4

OptiX OSN 3500

S
l
o
t
3
1

A
U
X

S
E
P
1
S
l
o
t
1
2

S
l
o
t
1
3

S
l
o
t
1
4

S
l
o
t
1
5

G G
S S
C C
C C
S
l
o
t
1
6

S
l
o
t
1
7

S
l
o
t
1
8

Regenerator

OptiX OSN 2500REG


High rate signals
SDH: STM-64, STM-16, STM-16
(FEC)

3R: Re-amplify, Re-shaping, Retiming

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page150

Regenerator (Cont.)

OptiX OSN 2500REG functions

Regenerates and pass-through line unit signals

Terminates and regenerates overhead bytes of the


regeneration section and transmit transparently other
overhead bytes

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page151

Regenerator (Cont.)

OptiX OSN 2500REG configuration

S
L
1
6

S
F
1
6

S
L
6
4

C
R
G

C
R
G

S
L
6
4

S
F
1
6

S S
L A
1 P
6

S
l
o
t
6

S
l
o
t
7

S
l
o
t
8

S
l
o
t
9

S
l
o
t
1
0

S
l
o
t
1
1

S
l
o
t
1
2

S
l
o
t
1
3

CRG:

Timing signal

System control &


communication

S
l
o
t
1

S
l
o
t
2

S
l
o
t
3

S
l
o
t
4

S
l
o
t
5

S
l
o
t
1
4

S
l
o
t
1
5

S
l
o
t
1
6

S
l
o
t
1
7

S
l
o
t
1
8

Fiber routing panel


SLOT 22
PIU

SLOT 23
FAN

SLOT 24
FAN

OptiX OSN 2500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page152

SLOT 25
PIU

Regenerator (Cont.)

OptiX OSN 2500REG fiber connection

Fiber connection for one REG

Fiber connection for multi-REGs

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page153

Regenerator (Cont.)

OptiX OSN 3500


High rate signals
SDH: STM-64, STM-16, STM-16
(FEC)

Low rate signals


PDH: E1/T1, E3/T3, E4
SDH: STM-1e
DATA: FE, GE, ATM, ...

3R: Re-amplify, Re-shaping, Retiming

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page154

Regenerator

OptiX OSN 3500 functions as REG & ADM


Add and drop tributary signals

PDH signals: E1/T1, E3/T3, E4

SDH signal: STM-1e

Cross-connect tributary & line unit signals

Cross-connect line units pass-through signals

Regenerates and pass-through line unit signals

Terminates and regenerates overhead bytes of the regeneration


section and transmit transparently other overhead bytes

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page155

Regenerator (Cont.)

D
3
4
S

OptiX OSN 3500


configuration as REG &
ADM

Tributary unit

Line unit

100 x E1s

STM-64

6 x E3s

STM-16 (FEC)

2 x STM-1e STM-16

S
l
o
t
1
9

S
l
o
t
2
0

S
l
o
t
2
1

D
7
5
S
S
l
o
t
2
2

S
l
o
t
2
3

D
7
5
S
S
l
o
t
2
4

D
7
5
S
S
l
o
t
2
5

D
7
5
S
S
l
o
t
2
6

A
U
X
P
I
U

P
I
U

FAN

S
l
o
t
1

S
l
o
t
2

S
l
o
t
2
9

S
l
o
t
3
0

S
l
o
t
3
1

S
l
o
t
3
2

S
l
o
t
3
3

FAN
G
X
C
S

G
X
C
S

S S S
L F L
6 1 1
4 6 6

S S S S S S
l l l l l l
o o o o o o
t t t t t t
3 4 5 6 7 8

S
l
o
t
9

S
l
o
t
1
0

S
l
o
t
1
2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Fiber Routing

Page156

S
l
o
t
3
5

S
l
o
t
3
6

S
l
o
t
3
7

FAN

P P P S S S
D Q Q L F L
3 1 1 1 1 6
6 6 4

OptiX OSN 3500

S
l
o
t
3
4

S
l
o
t
1
2

S
l
o
t
1
3

S
E
P
1
S
l
o
t
1
4

S
l
o
t
1
5

G G
S S
C C
C C
S
l
o
t
1
6

S
l
o
t
1
7

S
l
o
t
1
8

Regenerator (Cont.)

OptiX OSN 3500 fiber connection as REG & ADM

OSN
3500

SL64

SL64

IN

OUT

OUT

IN

IN

OUT

SL64

SL64

IN

OUT

OSN
3500

Fiber connection for REG

OSN
3500

IN

OUT

OUT

OUT

IN

IN

IN

OUT

OSN
3500

PQ1
SL16

SL16

SL16

SL16

Fiber connection for ADM

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page157

Common network elements


summary
ADM

ADM

MADM

REG

STM-64

REG

STM-16

STM-1

ADM

ADM
TM
Low-rate signals

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page158

Contents
1.

Product Introduction

2.

Cabinet, Sub-rack

3.

Boards

4.

Common Network Elements and Configuration

5.

Features

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page159

Equipment Protection -OSN1500


Items protected

Protection scheme

E1/T1 processing board

1:2 TPS

E3/DS3 processing board


E4/STM-1 processing board

1:1 TPS

FE Processing board
Core unit

1+1 hot backup protection

-48V power interface card

1+1 hot backup protection

3.3V card power supply


1:N centralized hot backup protection
* The OptiX OSN 1500 can support two TPS groups of different types of services at the one time.

1:2 TPS of E1/T1 board


SLOT 14
SLOT 15
SLOT 16
SLOT 17

Slot 20

FAN

1:1 TPS of E3/T3 board


SLOT 14
SLOT 15
SLOT 16
SLOT 17

SLOT 18 PIU
SLOT 19 PIU

Protection

SLOT 6 (622M)

Working

SLOT 7 (622M)
Slot 20

SLOT 18 PIU
SLOT 19 PIU

SLOT11

SLOT 6 (622M)

Protection

SLOT 7 (622M)

Working

SLOT 8 (622M)

Working

SLOT 8 (622M)

SLOT 4 CXL1/4, CXL16

SLOT 9 (622M)

SLOT 4 CXL1/4, CXL16

SLOT 9 (622M)

SLOT 5 CXL1/4, CXL16

SLOT 10 AUX

SLOT 5 CXL1/4, CXL16

SLOT 10 AUX

FAN

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page160

Equipment Protection OSN2500


Items protected

Protection scheme

E1/T1 processing card

1:N (N 4) TPS

E3/T3 processing card

1:1 TPS (2 Groups)

E4/STM-1 processing card

1:1 TPS (2 Groups)

FE processing board

1:1 TPS (2 Groups)

Core unit

1+1 hot backup protection

-48V power interface card

1+1 hot backup protection

3.3V card power supply

1:N centralized hot backup protection

* The OptiX OSN 2500 can support two TPS groups of different types of services at the
same time.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page161

Equipment Protection OSN2500


(Cont.)
S
L
O
T
1

S
L
O
T
2

S
L
O
T
3

S
L
O
T
4

S
L
O
T
5

S
L
O
T
6

S
L
O
T
7

S
L
O
T
8

S
L
O
T
9

S
L
O
T
10

C
X
L

C
X
L

S
L
O
T
11

W W

S
L
O
T
12

S
L
O
T
13

S
L
O
T
14

S
L
O
T
15

S
L
O
T
16

S
L
O
T
17

S
L
O
T
18

S
L
O
T
1

S
L
O
T
2

S
L
O
T
3

1:4 TPS of E1/T1 board

S
A
P
W W

2 groups 1:1 TPS for


E3/T3/E4/STM-1(e)/FE board

S
L
O
T
4

S
L
O
T
5

S
L
O
T
6

S
L
O
T
7

T
S
B
P

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

S
L
O
T
8

S
L
O
T
9

S
L
O
T
10

C
X
L

C
X
L

S
L
O
T
11

S
L
O
T
12

S
L
O
T
14
S
A
P

Page162

S
L
O
T
13

S
L
O
T
15

S
L
O
T
16

S
L
O
T
17
T
S
B

S
L
O
T
18

Equipment Protection OSN3500


Items protected

Protection scheme

E1/T1 processing board

1:N (N 8) TPS

E3/T3 processing board

1:N (N 3) TPS (2 Groups)

E4/STM-1e processing board 1:N (N 3) TPS (2 Groups)


FE Processing board
1:N (N = 1) (2 Groups)
Cross-connect and timing
unit

1+1 hot backup protection

SCC unit

1+1 hot backup protection

-48V power interface board

1+1 hot backup protection

3.3V board power supply

1:N centralized hot backup protection

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page163

Equipment Protection OSN3500


(Cont.)

1:8 TPS of E1/T1 board

Working

Working
Working

S
L
O
T
7

S
L
O
T
8

S
L
O
T
9

S
L
O
T
1
0

FE board1:1 TPS

S
L
O
T
1
1

S
L
O
T
1
2

S
L
O
T
1
3

S
L
O
T
1
4

S
L
O
T
1
5

S
L
O
T
1
6

S
L
O
T
1
7

S
L
O
T
1
8

S S
C C
C C

S
L
O
T
1

S
L
O
T
2

S
L
O
T
1

S
L
O
T
4

S
L
O
T
5

E1 Working

Working

S
L
O
T
6

E1 Working

Protection

S
L
O
T
5

3 groups of mixed TPS


S
L
O
T
3

E3 Working
E3 Protection
E1 Protection

S
L
O
T
4

Working

S
L
O
T
3

Working
Working

S
L
O
T
2

Working

S
L
O
T
1

S S S
2 3 L
O
T
4
F F
E E

P W

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

S
L
O
T
5

S
L
O
T
6

S
L
O
T
7

S
L
O
T
8

S
L
O
T
9

S
L
O
T
1
0

S
L
O
T
1
1

S
L
O
T
1
2

S
1
3

S S
1 1
4 5

E4
/1
5
5
M

E4 E4
/1 /1
5 5
5 5
M M

W WW

S
L
O
T
6

S
L
O
T
7

S
L
O
T
8

S
L
O
T
9

S
L
O
T
1
0

X
C
S

X
C
S

Page164

S
L
O
T
1
1

S
L
O
T
1
2

S
L
O
T
1
3

S S
L 1
O 5
T
1
4 F
E

S S S
1
L L
6
O O
T T
E4
1 1
/1
7 8
5
5
M
S S
P C C
C C

S S S
1 L L
6 O O
T T
1 1
F 7 8
E

S S
C C
W P C C

Equipment Protection (Cont.)

Fans

The mutual backup of power supplies for the fans

Automatic fan speed adjustment

Once one fan modules goes faulty, the others will operate at their full
speed.

Turns off the fans at low temperature

Abnormality-Specific Board Protection

Check function of application program and data

Over-voltage and under-voltage protection

Board temperature check

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page165

Network Level Protections


Protections
Linear MSP

Types
1+1 MSP
1:N (1 N 14) MSP
2-fiber bidirectional MSP ring

MSP ring

2-fiber unidirectional MSP ring


4-fiber bidirectional MSP ring

Mesh Protection

Intelligent function

SNCP
Dual node interconnection (DNI)
Fiber-Shared Virtual Path Protection
MS-Shared Optical Path Protection
RPR
VP-Ring/VC-Ring Protection

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page166

Intelligent Features

Service level agreement (SLA)

Topology automatic discovery function

Automatic end-to-end service configuration

Support mesh networking and protection

Traffic engineering

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page167

Resilient Packet Ring (RPR)

Topology automatic discovery function

Fair algorithm

3 service levels

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page168

Summary

Product Introduction

Cabinet, Sub-rack and Boards

Common Network Elements and Configuration

Features

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page169

Thank you
www.huawei.com

You might also like