Principle:
Confidential
Document
Principle:
In this figure, DXP detection
of this signal is temperature
PIN, it is connected to a
thermistor. normal working
hours, PWR_PSON # and
the PSON # is conduction,
DXP detect the CPU
temperature exceeds its
limit, Fengyun IC to Will
PWR_PSON # and PSON #
to turn off the system power
off, so to protect the CPU
overheat and burn Buzhi Yu.
Figure (f)
Confidential
Document
Confidential
Document
Confidential
Document
Confidential
Document
Confidential
Document
Confidential
Document
Check BIOS on ICHPCIRST # is OK, normal, then a +3 V voltage, the signal after pressing
the RSTCON # high to low by the sub-high.
2. Check BIOS on PCICLK_FWH is OK, normal, then you can measure with an oscilloscope
to the 33Mhz frequency.
3. Check BIOS on FWH_IC is OK, this signal is used to set the BIOS is a model which, when
high that the choice of the A / A MUX Mode (ISA architecture), is low that the FWH mode is
selected (LPC Architecture), the board in this machine through a resistor in this signals Pull
Low.
4. Check BIOS is on the FWHHINIT # OK, this is a BIOS initialization signal, normal, then you
can measure with an oscilloscope to the +3 V voltage.
5. Check BIOS on LAD0 ~ LAD3 four signals are normal, with three tables and the
oscilloscope with its two extremes and the voltage is normal.
6. If these signals are OK, as the BIOS information on the general air burning, can replace
the BIOS.
Confidential
Document
First Check Vcore voltage is normal, if not OK, then check the Vcore related lines.
2. Check CPU's CPUPWROK and CPU_RST # is normal, if CPUPWROK not, then check
whether the working conditions of South Bridge OK, if all OK, you can replace the South
Bridge. If not CPU_RST #, first check the supply voltage and frequency northbridge is
normal, then check the HUB-LINK between north and south bridge line is normal, if the
signal is OK, you can replace the North Bridge.
3. Check Host Bus frequency and CPU frequency is OK.
4. Check Host Bus's GTLREF is normal, the normal voltage of Vcore voltage two-thirds.
5. Check CPU's TESTHI signal is normal, if not correct for the CPU to the CPU will not work
there.
Confidential
Document
This is like the CPU has to move now, but in reading the address data file or data errors lead to the machine.
Specific maintenance steps are as follows:
1.
Check CPU of the HA [3:31] #, HD [0:63] #, HDSTBN [0:3] #, HDSTBP [0:3] # and HDBI
[0:3] # signals are those OK, mainly through the amount of Measured to determine the value
of two-body protection, for if there are Open or Short amount to the need to take the line to
determine Socket or North Bridge.
2. Check HUB_LINK between north and south bridge signal is normal. DEBUG lock step
when running, in the first time, DEBUG DATA and ADDRESS on the display is not correct,
such as: DATA: FFFFFFFF ADD: 00BFBFD0, then check these signals.
3. Check PCI interface signals AD [0:31] #, C / BE [0:3] #, FRAME #, DEVSEL #, IRDY #,
TRDY # and STOP # is OK.
4. If these signals are OK, it may be caused by bad bridge, south bridge replacement be
replaced, to replace the North Bridge.