You are on page 1of 8

PILE WORK

Sn
o

Cod
e
no.

1.

001
5

2.

001
7

3.

Description

Unit

Rate

Per
day

6000

Hire and running charges of tipper.

Per
day

1700

001
8

Hire and running charges of loader

Per
day

5000

4.

002
4

PLANT
ANDpiling
MACHINERY
Hire and running charges
of hydraulic
rig with power unit etc.
including complete accessories and shifting at site.

Per
day

3400
0

5.

002
6

Hire and running charges of bentonite pump.

Per
day

4200

6.

002
7

Hire and running charges of vibrating pile driving hammer complete with
power unit and accessories.

Per
day

3500
0

7.

002
8

Hire and running charges of crane 20 tonne capacity.

8.

008

Hire and running charges of drill machine up to 400 mm dia (including

Per
9300
day
PerTEAM7500

Hire and running charges of Tripod and Mechanical Winch machine.

LABOUR CHARGES
Sn
o.

Code
no.

1.

114

2.

3.

Description

Unit

Rate

Beldar

Per day

329

130

Mistry

Per day

435

160

Technician

Per day

700

TEAM

REQUIRED
Sn cod
Description

MATERIALS
Unit

Rate

Kilogram

50

o.

1.

7181

2.

7182 M.S. clamps for pile shoe

Kilogram

45

3.

7183 Bentonite

Tonne

3100

C.I. pile shoe

TEAM

Load Testing Of Pile


7246 Vertical load testing (initial) of piles in accordance with IS : 2911 (Part-IV)
including installation of loading platform and preparation of pile head or
construction of test cap and dismantling of test cap after test etc. complete
as per specification and up to 50 tonne capacity pile

Per test

3320
0

7247

50 tonne and up to 100 tonne Capacity of pile

Per test

40300

7248 group of two or more pile having capacity up to 50 tonne

Per test

48500

7249 Cyclic vertical load testing of piles in accordance with IS : 2911 (Part-IV)
including preparation of pile head etc. for Single pile up to 50 tonne
capacity .

Per test

15000

7250

Per test

23000

Per test

15000

Per test

23600

7251
7252
7253

for Single pile above 50 tonne capacity pile and up to 100 tonne capacity
pile
for Group of two piles up to 50 tonne capacity each
Lateral load testing of single pile in accordance with IS : 2911 part -IV for
determining safe allowable lateral load on pile up to 50 tonne capacity.
pile above 50 tonne capacity

TEAM

20.
1

Providing, driving and installing driven cast-in-situ reinforced cement


concrete piles of grade M-25 of specified diameter and length below the
pile cap, to carry safe working load not less than specified, excluding the
cost of steel reinforcement but including the cost of shoe and the length of
pile to be embedded in the pile cap etc. all complete. (Length of pile for
payment shall be measured from top of shoe to the bottom of pile cap) :
- 400 mm dia piles
- 450 mm dia piles
- 500 mm dia piles
- 550 mm dia piles
- 750 mm dia piles
- 1000 mm dia piles
- 1200 mm dia piles
- 1500 mm dia piles

20.2

It includes the cost of boring with bentonite solution and temporary casing
of appropriate length for setting out and removal of same and the length
of the pile to be embedded in the pile cap etc.
-450 mm dia piles
-500 mm dia piles
-600 mm dia piles
-750 mm dia piles

Metre
Metre
Metre
Metre
Metre
Metre
Metre

1926.5
2316.5
2846.8
3090.2
5236.4
5
8637.3
11160.
7

Metre
Metre
Metre
Metre

1665.3
1
5953.8
2671
5
4022.9
5

TEAM

20.
2A

20.3

20.6

It includes the cost of boring with bentonite solution and


temporary casing of appropriate length for setting out and
removal of same and the length of the pile to be embedded in the
pile cap etc.
-600 mm dia piles
-750 mm dia piles
-1000 mm dia piles
-1200 mm dia piles
-1500mm dia piles
It excludes the cost of steel reinforcement but including the cost of boring
with bentonite solution and the length of the pile to be embedded in pile
cap etc. all complete.
-300 mm dia pile
-400 mm dia pile
-450 mm dia pile
-5500 mm dia pile
Vertical load testing of piles in accordance with IS 2911 (Part IV) including
installation of loading platform by Kentledge method and preparation of
pile head or construction of test cap and dismantling of test cap after test
etc. complete as per specification & the direction of Engineer in-charge.
- Single pile upto 50 tonne Safe capacity.
- Initial test (Test Load 2.5 times the Safe capacity
- Routine test (Test Load 1.5 times the Safe capacity
- Initial test (Test Load 2.5 times the Safe capacity

Metre
Metre
Metre
Metre
Metre

3,629.
255,21
5.408,
683.15
11,334
.416,2
41.8

Metre
Metre
Metre
Metre

2,123.
15
2,569.
05
2,835.
95
3,153.
35

TEAM

20.7

20.8

20.9

Cyclic vertical load testing of pile in accordance with IS Code


of practice IS: 2911 (part IV) by Kentledge method including
preparation of pile head etc
-Single pile
-Up to 50 tonne Safe capacity pile
-Above 50 tonne and up to 100 tonne Safe capacity pile
-Up to 400 tonne Safe capacity of group
Lateral load testing of single pile in accordance with IS Code of
practice IS : 2911 (Part IV) for determining safe allowable lateral load
on pile
- Upto 50 tonne capacity pile
- Above 50 tonne and upto 100 tonne capacity pile
Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic
Echo Test method in accordance with IS 14893 including surface
preparation of pile top by removing soil, mud, dust & chipping lean
concrete lumps etc. and use of computerized equipment and high
skill trained personal for conducting the test & submission of results,
all complete as per direction of Engineer-in-charge

per test
per test

17,422.5
0
26,714.5
0
34,264.2
0

per test

Per test
Per test

Per test

17,422.
5
27,411.
4
745.50

TEAM

TEAM

You might also like