FGD Observation report-5

RVDF & Scrubber spray Nozzles


( Shree power Beawar)

Harish Yadav
Devendra Singh
EEDC/PCDC

Slurry nozzle found chock due to scaling in scrubber

Up to 33% Slurry spray nozzle found chock due to slurry


deposition in nozzle

Many Slurry distribution header found chock due to slurry


deposition

Air diffuser found in slurry spray nozzle reason for nozzle


chocking

Max. end nozzle of spray distribution header found chock opposite to


slurry entry.

Heavy scaling found most of suction line in RVDF

Many suction header found 100% chock due to partial


deposition in RVDF internal header

FRP coating found damage at many places in RVDF internal


side

Most of nozzle found 60% chock in RVDF internal suction header

Internal header suction branches found 100 % chock at many


places