Well Services Training Center
Function.
Types.
Components.
Body.
Energizer.
Stripper inserts or
stripper packers.
Lower and upper
bushings.
Non extrusion ring.
10 CTS Training Excellence in
Execution April 2009
Insert Materials
Characterized by their wear, temperature & chemical resistance.
Urethane (200F)
Nitrile (350F)
Viton (400F, H2S)
EPDM (500F)
Packing life depends on:
Hydraulic pressure.
Lubrication. HPHT stripper insert
Bushings condition.
http://www.benoil.com
11 CTS Training Excellence in
Execution April 2009
The Brass Bushings
Avoid contact friction
between the CT and the
Stripper body.
Minimize CT abrasion.
Guide the CT while stabbing.
Split
Decrease chance of
generating sparks.
Help prevent the extrusion
of the inserts.
Integral
Conventional assembly.
Side door assembly.
Tandem assembly.
Sidewinder.
Radial.
Over/under.
Function.
Components
.
Types.
Weep Hole
Blind Rams
Blind rams, which seals
the entire wellbore (no CT
inside).
Blind ram body
Blind ram front seal insert.
Rear seal in body rams.
Seal rubber material.
Only holds pressure in one
direction.
RAM BODY
35 CTS Training Excellence in
Execution April 2009
Actuator Assembly - Cutaway
HYDRAULIC
CLOSING
PASSAGES DRILLED RETAINER ELBOW
ADAPTER TUBE
THROUGH BONNET
SET SCREW &
WOODRUFF HEX
KEY INDICATOR
RETAINER
ACTUATOR
ROD
SLEEVE RETAINER
NUT BEARING
SEAL PISTON PISTON
CYLINDER ASSEMBLY
GUIDE ROD KEY
NUT STEM
SEAL PISTON
BONNET RETAINER HYDRAULIC
CAP
SEAL ELEMENT
RETRACT
PACK OFF
DWL0194 23 0797
Back up/
Emergency BOP
Pressure
Allow stripper
pressure to
increase & supply
51 CTS Training Excellence in to BOP circuit
Execution April 2009
Downhole Check Valves - BHA
Function: Prevents uncontrolled of fluids
from the well bore in case of CT pipe
failure
Types of check valve
Ball and Seat
Dart and Seat
Flapper
O Ring
Seat Removabl
e
Flapper Cartridge
containing
flapper
and seat
54 CTS Training Excellence in
Execution April 2009
TOT Hydraconn Quick Connector
Hazards while Stabbing the Injector
Head onto the BOP
Pinch Points WC: Hand Injury
Damaged Seals WC: NP
TOT is the only manufacturer of CT
injector head Hydraulic Quick
Connectors that are approved for
purchase by Schlumberger WS.
Must be ordered to match the union
configuration of the CA adapter
flange on top of the BOP
API Flanges
Open flanges - API 6B flange
Close face - API 6BX flange
Backup and
Nonextrusion Ring
O-ring
Reduced Pin OD
(For easier
stabbing.)
Beveled
Shoulders
Backup Ring
(some versions)
O-ring
R or RX Ring BX Ring
Pressure
Passage
Ring groove
Raised Face with 23 sides. Bolt Circle
HYD HYD
WHP
ROD
BOOSTER
WHP
seals
73 CTS Training Excellence in
Execution April 2009
HW Exercise
Assume Quad BOP 2.5 with the following hydraulic accumulator :
Gas precharge pressure : 1,400 PSI
Accumulator Volume : 10 gal
BOP Hyd cir. operation pressure : 2,700 PSI
BOP minimum Hyd. pressure : 1,500 PSI
How many times can the BOP rams be cycles in case of a power pack failure ?