You are on page 1of 46

Linux Host Installation and Integration for

Block

Upon completion of this module, you should be able


to:
Describe Linux storage connectivity limits and
guidelines
Describe the implementation of Linux FC
connectivity
Describe the implementation of Linux iSCSI
connectivity

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 1
Linux Host Installation and Integration for
Block

Lesson 1: Linux storage connectivity


This lesson covers the following topics:
Linux system limits and guidelines
Linux HBA utilities
Linux data alignment

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 2
Linux Connectivity: Requirements
One or more VNX storage systems
One or more Linux hosts
Supported HBAs, HBA drivers, switches and cables
Correctly configured switch zoning
Correctly configured network
A management station in the environment
Supported host and OS
Supported browser
Supported JRE
Network connectivity to storage systems

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 3
Operating System Limits and Guidelines
Host Initiators

16 Fibre Channel initiator ports per Linux host (Single or dual ported)
No mixing of HBAs from different vendors or HBAs with different PCI-interfaces (PCI-Express
with PCI-X HBAs)

SAN connections used for multipathing must be homogenous

Logical Units

The number of logical units seen by a host system is dependent on the OS SCSI scan
algorithm and HBA LUN scan limits

Supported Protocols: Fibre Channel, Fibre Channel over Ethernet


(FC0E), and iSCSI

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 4
Host HBA Utilities
Depending on the supported HBA one of the
following utilities can be used to view host
connectivity
Emulex HBAs: OneCommand Manager
Qlogic: SANsurfer CLI or GUI
Brocade: Host Connectivity Manager

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 5
Emulex OneCommand Manager: Port
Information

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 6
OneCommand Manager: Target Mapping tab

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 7
Qlogic SANsurfer scli example

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 8
Brocade Host Connectivity Manager

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 9
Using fdisk to Align a Linux Partition

Create a new partition

Select the primary partition

2048
Enter expert mode

Offset to the begin at 128

Write the changes to disk

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 10
Linux Host Installation and Integration for
Block

Lesson 1: Summary
During this lesson the following topics were covered:
Linux system limits and guidelines
Linux HBA utilities
Linux data alignment

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 11
Linux Host Installation and Integration for
Block

Lesson 2: Linux FC and iSCSI Connectivity


This lesson covers the following topics:
VNX FC connections to a Linux host
VNX FCoE connections to a Linux host
VNX iSCSI connections to a Linux host

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 12
Viewing Block Storage Ports

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 13
Initiator Registration Records: Fibre

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 14
Initiator Registration Records Format: Fibre
Channel
Hostname
Host IP address
Host HBA WWNs
128 bit number - WWNN + WWPN
VNX port WWNs
128 bit number - WWNN + WWPN
Operating system type
Allows appropriate response to host SCSI commands

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 15
Unisphere Host Initiators: Fibre

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 16
Initiator Information: Fibre

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 17
Emulex hbacmd listbas and targetmappings
commands

VNX port numbers

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 18
Qlogic SANsurfer scli example

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 19
Viewing SP Fibre Channel Port Properties

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 20
Linux Servers and FCoE CNA Adapters

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 21
Initiator Registration Records: iSCSI Names
iSCSI address
Uniquely identifies nodes
Two variations
iqn. iSCSI Qualified Name (IQN)
iqn.1992-04.com.emc:cx.fnm00130702376.a5
iqn.1992-04.com.emc:cx.fnm00130702376.b5
eui. Extended Unique Identifier (EUI)
eui.50060162AEA5574E

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 22
Linux iSCSI NIC Initiator File and Target
Discovery
Each server connected to an iSCSI storage system
must have a unique iSCSI initiator name for its NICs
Linux iSCSI driver gives the same name to all NICs
in a server
/etc/initiatorname.iscsi
Displays the host iscsi iqn initiator name
/var/lib/iscsi/nodes
Displays discovered iSCSI target ports and iqn
identifier

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 23
Linux initiator and target discovery
commands

Display iscsi initiator name

Directory for iscsi node information

Display iscsi target port iqn


names

Displays iscsi network IP address

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 24
Unisphere Host Initiators: iSCSI

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 25
Initiator Information: iSCSI
Click icon to add picture

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 26
Viewing iSCSI Front-end Port Properties

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 27
Linux Host Installation and Integration for
Block

Lesson 2: Summary
During this lesson the following topics were covered:
VNX FC connections to a Linux host
VNX FCoE connections to a Linux host
VNX iSCSI connections to a Linux host

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 28
Linux Host Installation and Integration for
Block

Lesson 3: Implementing Linux Connectivity


This lesson covers the following topics:
Implementing Linux FC Connectivity
Implementing Linux iSCSI Connectivity

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 29
Linux Connectivity Steps

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block - 30
Host Registration

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 31
Unisphere Host Agent Installation

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 32
Configuring the Unisphere Host Agent
Host agent configuration file must include an entry
that defines the user who will issue the CLI
commands as a privileged user

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 33
Hostagent Commands
Hostagent can be:
Started
Stopped
Verified
Execute the ./hostagent command/s from the /etc/init.d
directory

Verify agent status

Stop the agent

Verify the hostagent process is stopped

Start the agent

Verify the hostagent is running

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 34
Verify Host Agent with Unisphere

Selecting the LUN Status tab and clicking on Update


produces a Error when the agent is not available.

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 35
Naviseccli port and getagent Commands

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 36
Unisphere Server Utility

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 37
Creating a Storage Group

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 38
Adding LUNs to a Storage Group

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 39
Adding Hosts to a Storage Group

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 40
LUN Scanning

Mechanisms for reconfiguring devices on a


Linux host
System Reboot
# reboot
HBA driver reload
Echoing the SCSI device list in /proc
Executing a SCSI scan function through
attributes exposed to /sys
SCSI scan through HBA vendor scripts
lun_scan for Emulex

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 41
Verifying LUNs after a reboot or rescan:
/proc/scsi
After a reboot or bus
rescan, verify the LUN
is available to the OS
by opening the scsi file
from the /proc/scsi
directory. LUN 60 is now
available.
LUN as viewed in the storage group
Selected LUNs

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 42
Create and mount a Linux File System
mkfs.ext3 to create a file system on the emcpower partiton

mkdir to make a directory and mount the file


on the directory

Use touch <data> to write data to the mounted file system

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 43
Linux iSCSI CHAP Configuration

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 44
Linux Host Installation and Integration for
Block

Lesson 3: Summary
During this lesson the following topics were covered:
Implementing Linux FC Connectivity
Implementing Linux iSCSI Connectivity

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 45
Summary
Key points covered in this module:
Connectivity requirements include:
Supported HBAs, HBA drivers, vendor management
software, and proper cabling to the fabric switches.
Fabric switches properly configured and zoned
Management station with supported OS, Web
Browser, Java, and network connectivity to the VNX.
Several configuration are key to successful host
integration, such as initiator records and port
properties
Steps to implement Linux connectivity in both a
Fibre Channel and iSCSI environment.

Copyright 2014 EMC Corporation. All Rights Linux Host Installation and Integration for Block 46