HYDRAULIC POWER
Hydraulic Power
Introduction
General Description
Hydraulic Power -General
Theory of Operation
Hydraulic-System Simplified Schematics
Hydraulic-System Components, Maintenance Access
Indication
General
1 2
3
Hydraulic System
SYSTEM 2
SYSTEM 3
Each system uses a primary and a back-up hydraulic pump to maintain system pressures
Description
•The hydraulic systems are installed with maximum segregation between the three systems
–Minimizes the possibility of a single failure causing the loss of more than one system
•Distribution of the flight control has been designed to make sure that the A/C remains controllable in the
event of any two of the hydraulic systems being unavailable
•Primary hydraulic power is supplied to the hydraulic system 1 by an engine driven pump (EDP)–1A EDP
and the secondary power is supplied to the hydraulic system by an AC Electric Motor-Driven Pump
(ACMP)–1B ACMP
•Primary hydraulic power is supplied to the hydraulic system 2 by an engine driven pump (EDP)–2A EDP
and the secondary power is supplier to the hydraulic system by Electric Motor-Driven Pump (ACMP)–
2B ACMP
Secondary power is supply to system 2 by means of a Power Transfer Unit (PTU) using hydraulic
system power from system 1
•Primary and secondary hydraulic power is supplied to the hydraulic system 3 by ACMPs
–3A ACMP (primary pump)
–3B ACMP (backup pump)
Hydraulic Systems
*NOTE: This valve is never to be used for the purpose of relieving thesystem bootstrap pressure. That function
is always accomplished by use of the manual pressure-relief valve (referred to as the dump valve).
1A 1B 2A 2B 3B
3A
PMP05V-34 PMP05V-34 Pump
AP6VSC-124 AP6VSC-124 PMP05V-34
PUV Unloader
Valve
FILTER MANIFOLD FILTER MANIFOLD
FILTER MANIFOLD
L.H. Thrust R.H. Thrust
PV PV
Reverser Reverser FLV Flow Limiter Valve
System System
ACCUMULATOR L.H.+R.H. G.S. #2 ACCUMULATOR L.H.+R.H. G.S. #1 PV
(OUTBOARD) (INBOARD)
System Priority
L.H.+R.H. M.F.S. #3 L.H.+R.H. M.F.S. #4 L.H.+R.H. M.F.S. #5 Valve
(INBOARD) (CENTER) (OUTBOARD) ACCUMULATOR
L.H. Outboard Upper L.H. Inboard R.H. Inboard Lower R.H. Outboard
ELEVATOR (A/S) RUDDER (A/S) ELEVATOR (A/S) ELEVATOR (A/S) RUDDER (A/S) ELEVATOR (A/S)
PV
Nose Wheel
Power Transfer Unit LANDING GEAR Steering
MPP1C-12
Retraction Extension
Nose Main
Emergency Uplock Landing Landing Emergency Uplock
Release (Mechanical) Gear Gear Release (Mechanical)
N° 1 System
System #1 and #2 capacities and pressures
Movie
System Components
System Components
System Components
PTU / SYNOPTIC
PTU Logic
EDP‘s / SYNOPTIC
EDP Operation
EDPs De-Pressurization Control Logic
ACMP
ERJ-170 Pump Motor Package
ACMP:
Flow- 3.7 gal/min
Press.-2700 +/-200 PSI
Hydraulic Power
ACMP´S / SYNOPTIC
ERJ-170/190
3.7 Gal/min
ACMP Logic
ACMP 1B Logic
ACMP 1B
Pre-Command
FLAP SPDA ELEC PMP 1
0º hold Low for 1.4
sec before COMMAND
going high
ENG
TRUE
AIR
TRUE Timer limits level of RMS motor current when
pressure hovers about pressure switch trip point
FLAP
0º
ENG
TRUE
AIR
TRUE
Energize
Reset EMER Park Brake Timer when
Signal transitions from ON set to ON not set ACMP 2B
Possible Contactor
Ground 2B
Taxi Hangar
hold HI for 360 sec Test
EMER Park Brake ON valid & not set before
going low
Left Engine N2 > 40% (active ch.) ACMP 2B
2B
ENABLE
Right Engine N2 > 40% (active ch.)
HYD ENG PMP 2 PRESS AC BUS 1
SWB LOW valid & set hold HI for 120 sec
before
NOT(Right Engine N2 valid & >40%) going low
(active channel)
Reset if AUTO
mode de-selected
HYD ELEC PMP 2 SWB AUTO valid & set
Set Points
Sys1 Sys2 Sys3
170 17% 22% 18%
190 19% 22% 18%
EICAS messages
“HYD 1 OVERHEAT”
HYD SYS 1 TEMP valid & > 145 degC 1.0 sec
Warning Message
set delay
Overheat Logic
WOWB = AIR
HYD ELEC PMP 1 SWA ON valid & set 8 sec
set delay
Electrical Pump Fail Logic
“HYD 3 LO PRESS” CAS Message not set
5.0 sec
HYD ELEC PMP 3A set delay
8 sec
SWA ON valid & set set delay
HYD ELEC PMP 3A PRESS
SWA LOW valid & set
“HYD3 ELEC PUMP A FAIL”
Advisory Message
WOWA = AIR
WOWB = AIR
IDG1 OFF valid & set
Generate a 9 sec LOW state
RAT
when input signal transitions
Deploy
IDG2 OFF valid & set from LOW to HIGH
APU GEN OFF valid & set
Task Approach