You are on page 1of 61

Internal

OptiX SDH/OSN Series


Equipment General
Configuration
www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved


References

 OptiX T2000 Operator Guide for SDH


 OptiX iManager T2000 Administrator
Guide for SDH
 OSN3500&2500&1500 Configuration
Guide
 OSN7500 Configuration Guide

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 1


 Upon completion of this course, you will be able to:
 Understand the menus of OptiX iManager T2000
 Create Topology including create NE/Link
 Perform the NE configuration, board configuration, service
dispatching and protection configuration for equipment via
OptiX iManager T2000
 Perform the Security Management, including Create NE User,
managing NE/T2000 login

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 2


Chapter 1 Creating Topologies

Chapter 2 Configuring Protection

Chapter 3 Configuring Services

Chapter 4 Configuring Clock

Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3


Chapter 6 Configuring Alarm and Performance
Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4


Creating Topologies

 Recommended Creation Sequence

Step Description

1 Creating GNEs & NEs

2 Creating a Sub-racks and Boards

3 Creating Links

4 Creating a Topology Subnet

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5


Creating Topologies

 Creating Optical NEs in batch


 Select [File/Search for NE] from the Main Menu.
 Click <Start Search>. The NEs found are
displayed after the search.
 Click <Stop Search>, and click <Yes> in the
confirmation box.
 Click <Create NE>.
 Enter the NE user name and password.
 Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6


Creating Topologies
 Creating Optical NEs Manually
Creating Gateway Network Element (GNE)
1. Click File/Create/Topology Object.
2. Choose the NE type to be created.
3. Complete the following information: ID,
extended ID, name and remarks.
4. Select "Gateway" from the "Gateway Type"
drop-down list and "IP" from the "Protocol" drop-
down list. Enter the IP address and port number
of the GNE.
5. Enter the NE user and password.
6. Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7


Creating Topologies
 Creating Optical NEs Manually
Creating Non-Gateway Network Element
1. Click File/Create/Topology Object.
2. Choose the NE type to be created.
3. Complete the following information: ID,
extended ID, name and remarks.
4. Select "Non-Gateway" from the "Gateway Type"
drop-down list. Select the GNE the NE is
affiliated to from the "Affiliated Gateway" drop-
down list.
5. Enter the NE user and password.
6. Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 8


Creating Topologies

 Creating Sub-racks and Boards (1/2)


 Double-click unconfigured NE icon on the Main Topology.
 Select "Manual Configuration" and click <Next>.
 Click <OK> in the two "Confirm" dialogue box.
 Set the NE attributes and click <Next>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9


Creating Topologies

 Creating Sub-racks and Boards (2/2)


The NE Panel is displayed.
1. Right-click the slot and select the board type or Click
<Query Physical Slot (s)> to upload the data to the physical
slot from the NE.
2. After all the boards have been created, click <Next>.
3. Click <Finish>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10


Creating Topologies
 Creating fibers manually
 Searching fibers 1. Select the shortcut icon on the
 Select [File/Search for Fiber/Cable]. toolbar of the Main Topology and the
cursor changes to a "+".
 Click <Search>.
2. Click the source NE of the fiber or
 After finding the fibers, Click <Close>.
cable on the Main Topology.
 Click <Create Fibre>.
3. Select the source board and port.
4. Click <OK> and the cursor changes to
a "+".
5. Click the sink NE of the fibre or cable
on the Main Topology.
6. Select the sink board and port
7. Click <OK> twice.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11


Creating Topologies

 Creating a Topology Subnet

1. Select [File/Create/Subnet].
2. Select the "Basic Attributes" tab. Enter the
information of the subnet.
3. Select the "Object Selection" tab. Select the
created NEs or subnet from the "Object Not
Selected" pane, and add them to the "Selected
Object" pane by clicking the double-right-arrow
button.
4. Click <OK>.
5. Click in the Main Topology.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12


Chapter 1 Creating Topologies

Chapter 2 Configuring Protection

Chapter 3 Configuring Services

Chapter 4 Configuring Clock

Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13


Configuring Protection
Equipment level protection

Configuring TPS Protection Configuring Board-level Protection

Network level protection

Configuring MSP Ring Configuring SNCP

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14


Configuring Protection
Equipment Level Protection
 Configuring TPS Protection
 In the NE Explorer, click the NE and select [Configuration/TPS Protection]
from the Function Tree.
 Click <Create> to enter the dialog box .
 Select a protection board and working boards. Set switching priorities for the
working boards.
 Set the "WTR Time“.
 Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 15


Configuring Protection

 Creating Board-level Protection


 In the NE Explorer, click the NE and select [Configuration/Board-Level
Protection] from the Function Tree.
 Click <New>.
 Select Primary Board and Standby Board, and set Protection Group ID.
 Click <OK>.
 Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16


Configuring Protection
Network Level Protection

 Creating a Two-Fiber MS-SPRing


 Select [Configuration/Protection View]
 Select [Protection View/Create SDH Protection Subnet/2f_MS SPRing].
 Select the rate of the protection subnet.
 Double-click on the nodes to be in the protection subnet.
 Click <Next>.
 Click <Finish> to send the configurations.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17


Configuring Protection

 Configuring SNCP Protection


 Select [Configuration/Protection View] from the Main Menu.
 Right-click the NE to be created as the SNCP node, and select [Create
SNCP Node/Create xxx SNCP Node] ("xxx" refers to the name of the
protection subnet of this NE)

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 18


Chapter 1 Creating Topologies

Chapter 2 Configuring Protection

Chapter 3 Configuring Services

Chapter 4 Configuring Clock

Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19


Configuring Service
Configuration Method

Using the Trail Management Using the Single Station


Function Function

Service type

Configuring Configuring Configuring ATM


SDH/PDH service Ethernet service service

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20


Method 1 -- Using the Trail Management Function

 Configure SDH/PDH service


 It is recommended to configure SDH services by the process
below
Stage Description Remark
According to trail level:
 Creating a VC4 Server Trail
1 Creating an SDH trail
 Creating a VC4/VC4-Xc Trail
 Creating a VC12/VC3 Trail
2 Changing Trail Type Optional

3 Viewing Trail

Configuring the Maintenance Parameters


4
of a Created Trail
5 Deleting a Trail Optional

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21


Method 1 -- Using the Trail Management Function
 Creating a VC4 Server Trail
 Select [Trail/SDH Trail Creation] from the Main Menu.
 Set the service direction to "Bidirectional" and level to "VC4 Server Trail".
 Double-click the source NE and then the sink NE. The trail selected automatically
will be displayed between the NEs.
 Set a name and ID for the route.
 To send the configurations to the NE, select the "Activate" checkbox. (optional)
 Select the "Copy after Creation" checkbox if you want to create multiple trails with
the same route. (optional)
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates
operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 22


Method 1 -- Using the Trail Management Function

 Creating a VC4 Server Trail

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 23


Method 1 -- Using the Trail Management Function
 Creating a VC-12/VC3 Trail
 Select [Trail/SDH Trail Creation] from the Main Menu.
 Select the service direction and set the service level to "VC12" or "VC3".
 Double-click the source NE and then the sink NE. Select the port in the "Create Trail-
Select Board Port" dialogue box and click <OK>.
 Click the "Trail setting" tab. Set a name and ID for the route.
 To send the configurations to the NE, select the "Activate" checkbox.
 Select the "Copy after Creation" checkbox if you want to create multiple trails with the
same route. (optional)
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates
operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 24


Method 1 -- Using the Trail Management Function

 Creating a VC-12/VC3 Trail

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 25


Method 2 -- Using the Single Station Function

 Configure SDH/PDH service


 In the NE Explorer, click the NE
and select [Configuration/SDH
Service Configuration] from the
Function Tree.
 Click <Create>.
 Complete the information as
required.
 Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 26


Chapter 1 Creating Topologies

Chapter 2 Configuring Protection

Chapter 3 Configuring Services

Chapter 4 Configuring Clock

Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 27


Configuring Clock

 Setting the System Clock Source Priority List


 Setting Switching Conditions for a Clock Source
 Setting Restoration Parameters for a Clock Source
 Setting an External Clock Source
 Setting the Clock Subnet

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 28


Configuring Clock

 Setting the Priority Table for a Reference Clock


 Select [Configuration/Clock View] from the Main Menu.
 Right-click the NE icon in the Clock View and select [Clock Source Priority List].
 Click <Create>, and the "Add Clock Source" dialogue box is displayed.
 Select a reference clock source and click <OK>.
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates
operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 29


Configuring Clock

 Setting Switching Conditions for a Clock Source


 In the NE Explorer, click the NE and select [Configuration/Clock/Clock Source
Switching] from the Function Tree.
 Select the "Clock Source Switching Condition" tab. Click <Query>.
 Double-click the parameters to set clock switching conditions.
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates
operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 30


Configuring Clock
 Setting Restoration Parameters for a Clock Source
 In the NE Explorer, click the NE and select [Configuration/Clock/Clock
Source Switching] from the Function Tree.
 Select the "Clock Source Reversion Parameter" tab. Click <Query>.
 Double-click the parameters to set restoration parameters.
 Click <Apply>. The "Operation Result" dialogue box is displayed and
indicates operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 31


Configuring Clock
 Setting an External Clock Source
 Right-click the NE icon in the Clock View and select [Clock Source
Priority List].
 Set "External Clock Source Mode" and "Synchronous Status Byte" for
the external clock source.
 Click <Apply>. The "Operation Result" dialogue box is displayed and
indicates operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 32


Configuring Clock
 Setting the Clock Subnet ---- Setting a Clock Subnet Attributes
 Right-click the NE icon in the Clock View and select [Clock Subnet Settings].
 On the "Clock Subnet" tab, set the clock subnet parameters.
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation
succeeded. Click <Close>.
 Select the "Clock ID Status" tab. If a clock ID is assigned to the line clock source, set "Clock ID
Status" to "Enabled".
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation
succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 33


Configuring Clock
 Setting the Clock Subnet --- - Setting Clock Source Quality

 Right-click the NE icon in the Clock View and select [Clock Subnet Setting]. Click the "Clock
Quality" tab.
 Set "Configuration Quality".
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded.
Click <Close>.
 Select the "Manual Setting of 0 Quality Level" tab. Set the quality for the unknown clock source.
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded.
Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 34


Configuring Clock

 Setting the Clock Subnet ---- Setting SSM Output


 Right-click the NE icon in the Clock View and select [Clock Subnet
Setting]. Click the "SSM Output Control" tab.
 Set "Control Status" of the clock source.
 Click <Apply>. The "Operation Result" dialogue box is displayed and
indicates operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 35


Chapter 1 Creating Topologies

Chapter 2 Configuring Protection

Chapter 3 Configuring Services

Chapter 4 Configuring Clock

Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 36


Configuring Overhead Interface

 Configuring the Orderwire Phone


 In the NE Explorer, click the NE and
select [Configuration/Orderwire] from the
Function Tree. Select the "General" tab.
 Set "Call Waiting Time (s)", "Dialing
Mode", "Telephone No." and the
Orderwire ports.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 37


Chapter 6 Configuring Alarm and Performance
Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 38


Setting Alarm Dump Conditions
 1.Select [System Administration/Database
Management/Dump] from the Main Topology.
 2. Select the “Dumping Conditions” tab. In the
left-hand “Record Type” list, select “Alarm Event” .
 3. In the right-hand pane, under “Dumping when
Overflow”, set a value for “Max. Storage Capacity”,
“Number of Dumped Records” and “Capacity
Alarm Threshold” respectively.
 4. Under “Dumping in Schedule”, set "Dump
Periodically or not" to "Yes".Set "Dump Interval"
and "Time Limit" , then click <OK>

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 39


Setting Performance Monitoring Start/Stop Status
1.Select [Configuration/NE Time Synchronization] from the Main Topology
2. Select NEs from the object tree and then right click to select [Synchronize with NM Time]. Click
<Yes> in the pop-up confirmation box.
3.A dialog box is displayed to prompt that synchronization succeeded. Click <OK>
4.Select [Performance/NE Performance Monitor Time] from the Main Topology
6.Perform the following settings , then Click <Apply>
Set 15-minute Monitoring: Open
Set 24-hour Monitoring: Open
Start time: set as required and must be later than the current time of the NM and NE.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 40


Chapter 6 Configuring Alarm and Performance
Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 41


Synchronization and Data Management

 Synchronizing NE Time

 Synchronizing Current NE Alarms

 Managing NE Configuration Data

 Backing Up/Restoring the NE Database Using FTP

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 42


Synchronizing NE Time with the NM Server
 Manual Synchronization
 1.Select [Configuration/NE Time Synchronization] from the Main Menu
 In the left pane, select one or more NEs
 2.Modify the value of “Synchronize Mode” to “NM” then click <apply>--<close>
 3.Select one or more NE entries. Right-click and select [Synchronize with NM
Time].
 Automatic Synchronization
 1.Select [Configuration/NE Time Synchronization] from the Main Menu.
 2.In the left pane, select one or more NEs
 3.Set “Synchronize Starting Time” and “Synchronization Period”.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 43


Synchronizing Current NE Alarms
Synchronizing Networkwide Alarms

Select [Fault/Synchronize Networkwide Alarms]


from the Main Menu. A progress bar is displayed.
Synchronizing NE Alarms

Select an NE in the Main Topology

Right-click the selected object and select


[Synchronize Current Alarm]. A progress bar is
displayed.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 44


Backing Up NE Configuration Data

1.Select [Configuration/Configuration Data Management] from the Main Menu

2.In the left pane, select the desired NEs

3.Select one or more NEs in the “Configuration Data Management List”.

4.Click <Backup NE Database>. This is also available in the shortcut menu

5.A dialog box is displayed to prompt that backup succeeded. Click <Close>

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 45


Backing Up NM Configuration Data
1.Select [File/Logout] from the Main Topology. Click <OK> in the subsequent prompt.
2.Enter the following in the login interface
3.Select [System Administration/Single User Mode] from the Main Topology. Click <OK> in
the subsequent prompt.
4. To backup immediately :Select [System Administration//Database Management/Backup]
from the Main Topology. Select immediate backup, and the system backs up the NM database
to the appointed directory immediately
5.To backup periodically, perform the following settings

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 46


Chapter 6 Configuring Alarm and Performance
Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 47


Creating an NE User
1.Select [System Administration/NE Security Management/NE User Management] from
the menu
2.Select NE from the object tree. Select NE and click <Add>.
3.Enter the name, user level, user flag, password, and detailed description of the new NE
user: e.g. create a unified NE user “t2000” for NE1–NE5, as shown in the diagram below.
The length of the password of the NE user ranges from 6 to16 characters, including at least
one letter and one numeral. And the length of the “NE User” ranges from 2 to 8 characters

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 48


Chapter 6 Configuring Alarm and Performance
Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 49


Configuring communication
 Setting NE Communication
Parameters
 1. In the NE Explorer, click the
NE and select
[Communication/Set
Communication Parameters]
from the Function Tree
 2. Click <Refresh> to update the
communication parameters
 3. Modify the IP, Extended ID,
Gateway IP, Subnet Mask or
NSAP Address as you need, and
click <Apply>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 50


Configuring communication
 Changing an Ordinary NE into a GNE
 1. Select [System Administration/DCN Management] from the Main Menu
 2. Select the “NE” tab.
 3. Right-click an ordinary NE and select [Change to GNE]. The “Change to GNE”
dialog box is displayed;
 4. Set the “GNE type”, “IP Address” and “Port No.” as you need

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 51


Configuring communication
 Adding Standby GNEs for an NE

 1. Select [System Administration/DCN Management] from the Main


Menu
 2. Select the “NE” tab

 3. Select an NE entry, add standby GNEs

 4. Click <Apply>

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 52


Chapter 6 Configuring Alarm and Performance
Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 53


Configuring Board Parameters

 Configuring SDH Boards

 Configuring PDH Boards

 Configuring Ethernet Boards

 Configuring Optical Amplifier Boards

 …………………….

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 54


Configuring the Optical Transponder Unit

1, In the NE Explorer, select an SDH board and select [Configuration/SDH


Interface] from the Function Tree ;
2, Click the double-right-arrow button (red). Select "By Function" ;

3, Select the parameter in the drop-down list ;

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 55


Chapter 6 Configuring Alarm and Performance
Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 56


Reports
 The Network Diagram

 The Network wide Data Report

 The NE Information Report

 The Physical Location Information Report

 The Slot Configuration Report

 The Board Information Report

 The Slot Information Report

 The Board Details Report

 The Fiber/Cable Connection

 Report

 …………………..

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 57


Reports

The Network wide Data Report

1, Select [Report/Network wide Data


Report] from the Main Menu;
2, Click <Print> or <Save As>.

The Board Information Report

1. Select [Report/Board Information Report]


from the Main Menu ;
2. Select NEs from the left pane and click the
double-right-arrow button (red)
3. Select the "View Board Information" tab.
Click <Print> or <Save As>

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 58


 How to configure the SDH service?
Summary
answer
 How to configure the clock? answer

 How to backup the NE data configuration?


answer

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 59


Thank You
www.huawei.com

You might also like