You are on page 1of 14

3 PHASE CONTROLLED CONVERTER

WITH R LOAD
GROUP MEMBERS??
Ali Hamza EN15009
Fahad mehmood EN15005
Sarmad Razzaq EN15003
Tayyab Jatoi EN15007
Rana Zubair EN15001
INTRODUCTION
• Three phase convertors are 3-phase controlled rectifiers which are used to
convert ac input power supply into dc output power across the load.
Features of 3-phase controlled rectifiers:
• Operation from 3 phase ac supply voltage.
• They provide higher dc output voltage and higher dc output power.
• High output voltage ripple frequency
• They are used in high power variable speed industrial dc drives.
Circuit diagram
TO DERIVE AN EXPRESSION FOR THE AVERAGE OUTPUT VOLTAGE OF A 3-
PHASE HALF WAVE CONVERTER FOR CONTINUOUS LOAD CURRENT
TO DERIVE AN EXPRESSION FOR THE RMS VALUE OF THE OUTPUT VOLTAGE
OF A 3-PHASE HALF WAVE CONVERTER FOR CONTINUOUS LOAD CURRENT
Three phase half wave
controlled rectifier output
voltage waveforms for different
trigger angles with R load
TO DERIVE AN EXPRESSION FOR THE AVERAGE OR DC
OUTPUT VOLTAGE OF A 3 PHASE HALF WAVE
CONVERTER WITH RESISTIVE LOAD
• In the case of a three-phase half wave controlled rectifier with resistive
load, the thyristor T1 is triggered at ωt=(30°+α)and T1 conducts up to
ωt=180°=&pron; radians. When the phase supply voltage decreases to
zero at , the load current falls to zero and the thyristor T1 turns off.
Thus T1 conducts from ωt=(30° + α) to (180°).
• Hence the average dc output voltage for a 3-pulse converter (3-phase half
wave controlled rectifier) is calculated by using the equation
Thank You