You are on page 1of 7

RINSE WATER RECYCLING

FOR CHROME PLATING PLANT

Polyfill Microns Pvt. Ltd., www.polyfillmicrons.com


2

 Objective:
 To Recycle the rinse water

 To Recover chromic acid

 To Reduce waste

Polyfill Microns Pvt. Ltd., www.polyfillmicrons.com


PROCESS
3

• Rinse water 2-5 ppm chromic acid passed through


1st Exchanger
• Metals absorbed in 1st Exchanger
• Rinse water passed through 2nd Exchanger
• Chromic Acid absorbed in 2nd Exchanger
• Pure deionised water which comes out of 2nd
Exchanger can be collected and reused
• Absorbed chromic acid is stripped from the 2nd
Exchanger with NaOH
• Excess Alkali is absorbed in 3rd Exchanger
• 3-5% Chromic Acid recovered after 3rd Exchanger

Polyfill Microns Pvt. Ltd., www.polyfillmicrons.com


4

IMPURITIES REMOVED
Fe3+
Zn2+
Cu2+
Ni2+
Cr3+
Polyfill Microns Pvt. Ltd., www.polyfillmicrons.com
5

• Exhausted Cation resin


regenerated with 2 BV of
10% H2SO4 (or 10% HCl)
• Exhausted Anion resin
Regeneration regenerated with 2 BV of
Procedure 4% NaOH

Polyfill Microns Pvt. Ltd., www.polyfillmicrons.com


DM Water

Regenerant Regenerant
H2SO4 NaOH

IX IX IX
H2CrO4

Fe3+
Cr3+ Na2CrO4
Cu2+ (50 g/l CrO3) H2CrO4
Ni2+ (50 g/l CrO3)
Zn2+
CrO42-

Waste Water

Distilled Water

Polyfill Microns Pvt. Ltd., www.polyfillmicrons.com 6 Chromating Bath. H2CrO4 (400 g/l CrO3)
7

Thank You !

Polyfill Microns Pvt. Ltd., www.polyfillmicrons.com