You are on page 1of 9

ACS 800 ACS800 Drive series

ACS800-01, ACS800-02, ACS800-04, ACS800-07, ACS800-17, ACS800-37,


ACS800-11, Pedestal Modules for Cabinet Cabinet Cabinet
Wall mounting mounting Panel builder Mounting Mounting with Mounting with
with DSU regenerative ISU Low harmonic ISU

R2 – R6 R7 – R8 R7 – R8 75 – 2800 kW
1.1 – 110 kW 55 – 500 kW 55 – 560 kW

ACS600 - 1, rev. 1 Copyright © ABB Industry Oy


ACS 800 ACS800-07, 55-500kW

ACS800-04 drive unit

ACS600 - 2, rev. 1 Copyright © ABB Industry Oy


ACS 800 ACS800-07, over 500kW
DSU INU Width/mm
1 2 1330
2 2 1630 Cabinet width
2 3 1830
3 3 2030
2 4 2230
3 4 2430 ACS 800-07
3 5 2630
3 6 2830
4 6 3230
Common DSU DSU INU INU INU
DC-bus

Frame for
-control board
-I/O
-options

ACS600 - 3, rev. 1 Copyright © ABB Industry Oy


ACS 800 ACS800 MCC, switchgear mounted drives

ACS600 - 4, rev. 1 Copyright © ABB Industry Oy


ACS 800 ACS800 Marine

•ACS800 drives series can be used in all marine applications.


•ACS800 can be ordered with marine options where vibrations and other marine
industry needs are fullfilled.
•ACS800 drives has a type approvals for ABS, RINA, BV, GL, DNV and Lloyd's.

ACS600 - 5, rev. 1 Copyright © ABB Industry Oy


ACS 800 ACS800 with circuit brakers

ABB Tmax Moulded case circuit breaker, ABB miniature circuit breaker and
manual motor starters can be use instead of fuses up to 440kVA drives.

Fuses are reguired in the US market even if there is breaker protection!

ACS600 - 6, rev. 1 Copyright © ABB Industry Oy


ACS 800 ACS 800-07 Redundancy
Non Redundant drive
 Built-in redundancy through parallel connected modules

 Each inverter module (INU) is a complete three-phase inverter

 Each DSU module is a complete three-phase rectifier

 Enables running with partial load if one module fails

 Provides higher drive availability and greater process uptime

 Unique in drives - not available in previous generation ABB


drives or in existing competitors’ drives

 Reduced Run Function for inverters with APBU-44 branching unit Redundant ACS800-07
If one inverter module is broken:
• remove broken inverter module
• drive diagnostics indicates that one inverter module is missing (INT CONFIG)
• user’s must change the value of parameter 95.03 (16.10 in multidrive SW) one
number smaller
• Reset fault
• Start the drive!

 DSU modules can run automatically with reduced power after broken
module is removed

ACS600 - 7, rev. 1 Copyright © ABB Industry Oy


ACS 800
ACS800 ACS600

CDP 312R
CDP 312

ACS600 - 8, rev. 1 Copyright © ABB Industry Oy


ACS 800

X2
8 7 6 5 4 3 2 1

R2NC R2CM R2NO R1NC R1CM R1NO

X2

RXD
NDIO-02
DI GIT AL I /O
EXT ENSIO N

T XD

X1
DI1A DI1B DI2 A DI 2B +24V 0V

1 2 3 4 5 6 7 8
X1

ACS600 - 9, rev. 1 Copyright © ABB Industry Oy