MAGNETOM Espree

The first Open Bore MR with Tim


CT-like dimensions
in MR
3

70
4

125
5

1.5T
6

Tim
7

=
8

70 + 125 + 1.5T
+ Tim
9

Open Bore MR
+ Tim
10

=
11

MAGNETOM Espree
A Tim system
Tim
15

Tim - Total imaging matrix


MAGNETOM Espree

Select exams, not coils.


Up to [76x18]. 76 coil elements. 18 channels.

Local becomes total.


205 cm. Whole body.

Parallel in all directions.


PAT. Unlimited.
16

Evolution from LP to Matrix

Performance of
MR coil technologies Siemens
Tim
only:
Conventional Combination of
systems coils

More
coverage
IP
Array  76 coil elements with
40% up to 32 channels.
more SNR CP  Whole body coverage

First
Array with matrix coils.
CP  Flexible combinations
local coils
coils of coil elements.
LP  PAT optimized

coils  Maximum SNR

1983 1988 1993 1997 2003


17

Tim
Matrix Coils
18
19

MAGNETOM Espree - A Tim System


The First Open Bore MR

Tim [76x18]
Tim [32x8]
Tim
21

Workflow Automation

 Intuitive & Easy to Use


 Cross Modality
 Less Training Required

 Drag&Drop Image to Scan


Inline Technology
 Processing instead of
Post-Processing
AutoAlign
Pre- Pro- Dia-
paration
Scan
cessing gnosis  Push-Button
 Reproducible
22

Workflow Automation

Pro- Dia-
Pre- Scan
cessing gnosis
paration

Tim - Total imaging matrix


 Patient whole body set-up = one time set-up
 Patient repositioning = not required
 Coil reconfiguration = not required
Tim
Tim
25

Easy Access
Lowest Patient Table Height

 47 cm (1’7’’)
26

Lay Down and Relax


Most Comfortable Coils

 950 gr (2.1 lbs)


27

Only an Arm’s Reach Away


Smallest Distance to Isocenter

 62.5 cm (2’1’’)
28

The Most Desirable Way


Feet-First Examinations
29

A Wider Outlook
Extra-Wide Viewing Angle

 65° viewing angle


30

Room to Breathe
The First Time Ever - 70 cm Open Bore

 … resulting in 55.5 cm (1’10’’) patient gap


31

Raise the Roof


The First Time Ever - 70 cm Open Bore
 … resulting in 30 cm (1’) head room
32

See the Sky -


During Lumbar Spine Examinations
33

Take a Look -
With only 125 cm Magnet Length

 60% of anatomy can be performed


head outside the magnet
34

Provides MRI also to Obese Patients


The First Time Ever - 70 cm Open Bore

 70 cm (2’3’’)
Open Bore
Tim
36

Unprecedented
1.5 Tesla Applications
in Open MRI
37

Tim Application Suite


Standard with all Tim systems
Head / Neck
39

High resolution, fast imaging in Open MRI

 Sub-millimeter spatial resolution


in-plane: 0.4 x 0.7 mm²
 No compromise in
acquisition time

Courtesy of Turville Bay MRI, Madison


T2 TSE
230 mm FoV
512 matrix
TA 2:13 min
40

High resolution, fast imaging in Open MRI

 Shortest acquisition times


with Tim and iPAT
 High spatial resolution

Courtesy of Mayo Clinic, Jacksonville, USA


T2 TSE
PAT 2
512 matrix
TA 1:36 min
41

Highest spatial resolution in Open MRI

 Sub-millimeter resolution
 Visualization of small
distal vascular branches

3D FLASH Time-of-Flight (ToF)


448 matrix
eff. SL 0.9 mm
Spine
43

Sub-millimeter resolution in Open MRI

 High resolution T2 contrast


 For best diagnostic confidence

Courtesy of Turville Bay MRI, Madison, USA


T2 TSE Restore
256 matrix
220 mm FoV
TA 3:12 min
Vertebral Disk Prolapse
44

High-resolution in Open MRI

 Fast and high resolution


in open MRI
 Parallel Imaging in all
directions with Tim and iPAT

T1 TSE
PAT 2
SL 3 mm
448 matrix
TA 2:56 min
45

Whole-spine imaging in Open MRI

 Unique whole-spine imaging


in Open MRI
 Tim extends the anatomical
coverage according to the
individual clinical question
 No coil or patient repositioning

T2 TSE Restore
PAT 2
448 matrix
SL 3 mm
46

Tim – The Optimal Technology for Short Magnets

Typical 45 x 45 x 30 cm3

MAGNETOM Espree
A Tim System
47

Tim – The Optimal Technology for Short Magnets

Typical 45 x 45 x 30 cm3

MAGNETOM Espree
A Tim System
48
49

Head-out L-spine imaging

Courtesy of Turville Bay MRI, Madison, USA

 High image resolution


 Lumbar spine exams with
patient head outside the
magnet

T2 TSE Restore
270 mm FoV
448 matrix
SL 4 mm
TA 3:50 min
50
51

Patients with Low Back Pain can Raise Their


Knees for Added Comfort

 No other system allows this possibility


Extremities
53

1.5 Tesla detailed morphology in Open MRI

 High SNR
,  Feet-first examination
 Head-out

T1 SE
TA 4:47
448 matrix
SL 2 mm
54

Spectral water excitation in Open MRI

 Excellent fat suppression


 1.5 Tesla applications
 Sub-millimeter resolution
 High SNR with Tim

Courtesy of Turville Bay MRI, Madison, USA


3D DESS
140 x 140 mm² FoV
256 matrix
eff. SL 1 mm
Water Excitation
55

Spectral water excitation in Open MRI

 Excellent fat suppression


 1.5 Tesla applications
 Sub-millimeter resolution:
0.3 x 0.3 x 1 mm³

3D DESS Courtesy of Mayo Clinic, Jacksonville, USA

Water excitation
512 matrix
160 mm FoV
eff. SL 1 mm
56

High off-center magnet homogeneity

Courtesy of Turville Bay MRI, Madison, USA

 off-center fat suppression


 Feet-first examination
 High SNR

3D MEDIC
Water Excitation
120 x 120 mm² FoV
256 matrix
SL 1 mm
57

Multi-joint imaging in Open MRI

 Flexible coil combination


with Matrix coils
 Unique anatomical coverage in Open MR
 Ultra-fast imaging
with HASTE
 Reduced scan times
with Tim and iPAT

HASTE
PAT 2
3 steps
384 matrix
TA 2 s/ slice
Vascular
59

Highest spatial resolution in Open MRI

 Sub-millimeter resolution

3D FLASH ce-MRA, MIP Courtesy of Mayo Clinic, Jacksonville, USA


FatSat
220 mm FoV, 512 matrix
eff SL 1.5 mm
TA 26 s
60

Coronal thoraic angio with 400 mm FoV

 Sub-millimeter resolution
 Reduced breath-hold times
with iPAT

ce-MRA, MIP Courtesy of Mayo Clinic, Jacksonville


PAT 2
333 x 400 mm² FoV
384 matrix
TA 22.6 s
61

Peripheral MRI with Tim

 Single injection of 40 cc Gd
 6 steps with 33 cm FoV each

ce-MRA Courtesy of Mayo Clinic, Jacksonville

MIP
Body
63

Shortest breath-hold times in Open MRI

 Tim and iPAT for reduced acquisition


times
 2D PACE for prospective motion
correction
 Enables multi breath-hold image
acquisition

T1 FLASH
PAT 2
FoV 300x400 mm2
320 matrix
TA 12 s (!)
64

A new dimension of patient comfort


in Open MRI

 Ultra light-weight coils


 Free breathing

T2 TSE, PAT 2
Respiratory-gated
448 matrix
SL 4 mm
TA 2:29 min
65

RF fat saturation in Open MRI

 Homogenous FatSat
throughout the FoV
 Ultra-light weight coils

3D VIBE, post contrast Courtesy of Mayo Clinic, Jacksonville, USA

Spectral FatSat
256 matrix
TA 23.7 s
66

Highest spatial resolution in Open MRI

 Sub-millimeter resolution
 2D PACE for prospective
motion correction for
free-breathing exams

3D TSE Restore, MIP Courtesy of Mayo Clinic, Jacksonville, USA

PAT 2
240 mm FoV
256 matrix, SL 1.5 mm
Sclerosing cholangitis
67

People Who Never Tolerated an MR Scan (e.g.


due to Claustrophobia or Obesity) Have Been
Scanned Successfully.
68

Liver imaging of obese patient

 Fast imaging with HASTE


 450 mm FoV

T2 HASTE
Dark Blood
320 matrix
TA 1:43 min
Breast
70

Fast breast examinations in Open MRI

 Water excitation
 iPAT in 3D
 Short scan times
 Reduced artifacts

3D FLASH
PAT 2
320 matrix
TA 1:17 min
Tim
72

We remove typical

limitations
of Mid-Field Open MRI
73

Limitations of Mid-Field Open MRI

Limited Patient Comfort


 Claustrophobic effects
… due to magnet poles close to the patient

 Feelings of panic
… due to head-first entry

 Long duration of examination


… slower acquisition times, compared to highfield short bores
74

MAGNETOM Espree
A Tim System

Excellent Patient Comfort

950 gr (2.1 lbs) coil weight Feet First Exams Lumbar Spine Exams at 1.5 T
with head outside

55.5 cm (1’10’’) patient gap 70 cm (2’3’’) patient bore 30 cm (1’) head room
75

Limitations of Mid-Field Open MRI

Expensive Siting Requirements


 Higher investment in the building
… due to higher amount of concrete
… due to room shielding (in some cases)
… due to larger space requirements
* Hitachi Altaire siting up to 80 m 2 (861 ft2)
* GE Open Speed siting 38.9 m2 (419.2 ft2)
Competitive information provided is based on interpretation of available data and may require independent verification
76

MAGNETOM Espree
A Tim System

Lower area requirements = Lower costs

< 30 m² (323 ft²)


77

Limitations of Mid-Field Open MRI

Limited Patient Throughput &


Image Quality
 … due to slower gradient systems

 … due to older or conventional coil technology

 … due to maximum field strength of 0.7 Tesla


78

MAGNETOM Espree
A Tim System

High Patient Throughput &


Best Image Quality

 Strongest gradients in the industry


Z-engine with 33 mT/m @ Slew rate 100 T/m/s
 Ultra-fast image acqusition
 Short examination times

 Tim technology
 Highest workflow efficiency
 Best image quality - highest diagnostic confidence

 1.5 Tesla Field Strength


 For 1.5 Tesla high-field applications
79

and last
but not least …
80

MAGNETOM Espree
A Tim System

Lower operating costs

MAGNETOM Hitachi GE
Espree Altaire OpenSpeed

0.00 l/h Not specified


0.03 l/h
Boil-off normal in datasheet normal
operation operation

Not specified
Refills none 2 / year in datasheet

Power Not specified


Requirement
85 kVA in datasheet
105 kVA

Competitive information provided is based on interpretation of available data and may require independent verification
81

and looking
forward to …
82

Business Perspective
Marketing Support Tool Kit

MAGNETOM Espree MAGNETOM Espree

 The Marketing Support Tool Kit contains:


 Multimedia: website-builder, PowerPoint templates, patient testimonials on
video, radio spot, ...
 Print media: press releases, advertisement, direct mailings, billboard ads ...
 On-site material: patient flyer, safety stickers, posters, calendars, ...
 Image gallery: product photographs, clinical images, ... Available 1Q/2005
Tim
84

MAGNETOM Espree
A Tim System
85

You might also like