w 


 
? A multi-storey car park
or a parking garage is a
building (or part
thereof) which is
designed specifically to
be for automobile
parking
? there are a number of
floors or levels on which
parking takes place
V V  V   
PROJECT PLANNING

PROJECT CONSTRUCTION

PROJECT COMMISSIONING
TECHNICAL AND NON-
TECHNICAL INVESTIGATION

DEVELOPMENT OF
ALTERNATIVE SOLUTIONS

EVALUTION, COMPARISON
OF ALTERNATIVES

SELECTION OF THE MOST


FEASIBLE ALTERNATIVE

PREPARE THE DETAILED


PROJECT REPORT

SET OBJECTIVES OF A
PROJECT
DETAILED COST ESTIMATE OF THE
PROJECT

CONSTRUCTION METHOLOGY, SCH


EDULE

FINALISE PROJECT SUMMARY

DETAILED DESIGN AND PREPARATIO


N OF WORKING DRAWINGS

PREPARATION OF PLANS AND


SPECIFICATION
? planned manner preventing wastage of manpower,
materials and money
? ensuring completion of the project within stipulated
time, cost and quality
? the work of construction management along with
controlling and monitoring:
a) Activity schedule
b) Material schedule
c) Worker schedule
d) Fund schedule
e) Equipment schedule
? performance of the structure is evaluated

? nature of maintenance and repair is proposed

? quality inspection thoroughly to remove the defects

? prepare operating and maintaining manuals


Æ 
? Chennai airport site, tirusulam
? hard stratum
? hard rock at a depth of 2m
? water table at a depth of 6m.

? Need: The exponentially increasing frequency in the


use of airlines demands vast parking space, which is
obviously not feasible.
Project highlights
? Shear walls for seismic resistance
? Sufficient light and ventilation
? Fire safety
? Theft security
? Weather proof façade
? Water proofing
Project highlights͙
? Ramp (one way split level)
? Numerous entrance and exits
? Lift and stairs
? Hardcrete flooring
? Power supply room
? Security rooms
Project details
? Number of floors: 8
? Capacity: 500
? No. of cars per floor: 62
? Area of each floor: 940 sqm
? Total area: 7500 sqm
? Floor dimension: 31x31 sqm
? Floor height: 2.8 m
J 
? Since the site under construction is made of rocky
strata from a depth of 2m, pile foundation cannot be a
option.
? We suggest the design a shallow raft to suffice the 8
storey building.
amp design
? One way ramp Split level
 
 

 


  
  



The parking lot is as follows.
Parking space :
? width - 2.5 meters
? length - 4 meters
? Driving aisle width (2-way)
7 meters
? Two rows plus aisle width
15 meters V
J
? Since the flooring here should be abrasion resistant
and not be damaged by the vehicle movement we
provide hardcrete flooring.
? Hardcrete flooring is nothing but
V 
? Open and glass-backed elevator
? Security devices
-video, audio and emergency buttons that
call into the booth or local
? Eliminate potential hiding places, such as
under open stairs
? Handicap accessibility with vehicles close to
stair and elevator cores
? Non-slip floor surface

? Ventilation
? Energy efficiency in lighting
? Light should be vandal resistant and easy to
maintain.
? The lights should be placed in points such that no
place is in darkness.
? For the ventilation purpose the walls from the first
floor level is to the half height.
w 
? There are two entrance and exit.
? There are two sets of stairs and elevators.
? There is a power room and two security rooms.
? The roof of the 8th floor is given by truss over which
the roofing material is clad.
? The ramp is provided with glass walls in the exterior.
eferences and V codes
? IS 456:2000
? IS 875 (for calculation of design loads)
? IS 1893 (earthquake resistant design)
? IS 1904 (design and construction of foundation)
? SP 16 (design aid)
? Parking structures: planning, design, construction,
maintenance, and repair
(By Anthony P. Chrest, Mary S. Smith, Sam Bhuyan)

You might also like