HUAWEI BTS3900
Hardware Structure and PrincipIe
ISSUE1.0
WireIess Case and Training
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 2
BTS3900 Base Station is the fourth generation base station
deveIoped by Huawei. It features a muIti-mode moduIar design
and supports three working modes: GSM mode, GSM+UMTS
duaI mode, and UMTS mode through configuration of different
software. In addition, the BTS3900 supports smooth evoIution
to the Long-Term EvoIution (LTE).
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 3
now the functions and features of BTS3900
Master the hardware structure and function of BTS3900
Master the typicaI configuration and RF CabIe Connections
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 4
BTS3900 Hardware Description(V100R001_01)
HUAWEI BTS3900&BTS3900A MRFU DepIoyment Guide
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 5
Chapter 1 Chapter 1 BTS3900 BTS3900 Product Description Product Description
Chapter 2 BTS3900 System Structure
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 6
Location
PSTN
SDN
PSPDN
Um nterface
BTS3900
BTS3900
BTS3900
BTS
OMC
HLR/AUC/ER
BSC/RNC
MSC/VLR
SMC/VM
A/u nterface
MAP
TUP,SUP
MS
MS
MS
MS: Mobile Station BTS: Base Transceiver Station BSC: Base Station Controller
HLR: Home Location Register AUC: Authentication Center RNC: Radio Network Controller
MSC: Mobile Switching Center VLR: Visitor Location Register SMC: Short Message Center
VM: Voice Mailbox ER: Equipment dentity Register OMC: Operation and Maintenance Center
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 7
BTS3900 Product Description
The BTS3900 is comprised of the BBU3900, MRFU, and indoor macro cabinet. The
BBU3900 and the MRFU are installed in the indoor macro cabinet. The PS4890 meets
the requirements of different applications when the backup power or transmission
equipment space is required.
BTS3900 system structure
PS4890 system structure
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 8
Features of BTS3900
Advanced PIatform-Based Architecture
Based on the unified hardware platform, the BTS3900 supports three working modes: GSM
mode, GSM+UMTS dual mode, and UMTS mode through configuration of different software.
n addition, the BTS3900 supports smooth evolution to the Long-Term Evolution (LTE).
The RF module integrates the duplexer and the Transceiver Unit (TRU), thus enhancing integrity
of RF parts and meeting future requirements for a compact, high-efficiency, and low-cost base
station.
Supports whole frequency band of PGSM 900MHz, high 45MHz frequency band and low 45MHz
frequency band of DCS1800MHz, high 40MHz frequency band and low 40MHz frequency band
of 1900MHz.
High Capacity
When the BTS3900 works in GSM mode, a BBU3900 supports the maximum cell configuration
of S24/24/24.
When the BTS3900 works in GSM+UMTS dual mode, a BBU3900 supports the maximum cell
configuration of GSM S4/4/4 + UMTS S2/2/2 or GSM S5/5/5 + UMTS S1/1/1.
When the BTS3900 works in UMTS mode, a BBU3900 supports 24 cells, 1,536 CEs in the
uplink, 1,536 CEs in the downlink, and the maximum configuration of 3 x 8.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 9
Features of BTS3900
Transmission Sharing
Sharing the CPR port. The CPR data of the GSM and UMTS networks can be multiplexed on the
same optical cable, which reduces the quantity of CPR ports.
Supports co-transmission between the GSM and the UMTS. Sharing transmission resources
between the Abis and the ub interfaces.
FIexibIe CIock Synchronization Modes
Upper synchronization clock, extract clock from Abis/ub interface.
Extract clock from GPS (Global Positioning System).
Synchronization with the P clock, a highly cost-effective clock solution, which can be obtained
through software upgrade without additional hardware.
Clock phase lock, tracing, and memory functions and free-run synchronization mode. When the
clock operates in free-run mode, the system can keep operational for at least 90 days at normal
temperature.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 10
Features of BTS3900
etworking CapabiIity
The BTS3900 supports multiple network topologies, such as star, tree, chain, and ring
topologies.
Supports Flex Abis networking.
When working in UMTS mode, the BTS3900 supports ATM and P dual stack to protect
operators' early investment in ATM transport.
Supports optimized transmission on the Abis interface.
Low Power Consumption
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 11
Chapter 1 BTS3900 Product Description
Chapter 2 BTS3900 System Structure Chapter 2 BTS3900 System Structure
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 12
Abbreviation
Abbreviation Description
GTMU Transmission& Timing& Management Unit for BBU
WMPT WCDMA Main Processing and Transmission Unit
WBBPa WCDMA Baseband Process unit Type A
UTRP Universal Transmission Processing Unit
UPEA
Universal power and Environment interface unit
Type A (-48v)
BSBC Universal BBU Subrack Backplane Type C (2U)
UBFA Universal BBU Fan Unit Type A (2U)
UEU Universal Environment nterface unit
UELP Universal E1/T1 Lighting Protection unit
UFLP Universal FE/GE Lighting Protection unit
CPR Common Protocol Radio nterface
APM30H Advanced Power Module
HEUA The Heat Exchange Unit Type A
HPM The Hert Power Monitoring nterface unit
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 13
Sector 1 BTS3900 Sector 1 BTS3900 Cabinet Cabinet
Sector 2 PS4890 Cabinet
Sector 3 BTS3900 Hardware Components
Sector 4 BTS3900 ew Hardware
Sector 5 MRFU Working Mode
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 14
Appearance of the BTS3900 Cabinet
The BTS3900 cabinet is designed in compIiance with the IEC297 standard. It is a
verticaI cabinet.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 15
Hardware Structure of the BTS3900
Typical configuration of the BTS3900 cabinet (-48V)
Hardware Structure of the BTS3900 (-48V)
The BTS3900 cabinet (-48V) uses the external -48V DC input. The DC power is directly led
into the DCDU-01 and the DCDU-01 distributes the DC power to each component in the
cabinet.
The BTS3900 cabinet (-48V) consists of the following components: the MRFUs, BBU,DCDU-
01, and FAN unit. You can optionally install devices of 3U in height in the spare space of the
cabinet.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 16
Hardware Structure of the BTS3900
Hardware Structure of the BTS3900 (+24V)
The BTS3900 cabinet (+24V) uses the external +24V DC input. The PSUs (DC/DC) convert
the external input power into -48V DC power and supply the -48V DC power to the DCDU-
01.Then, the DCDU-01 distributes the -48V DC power to each component in the cabinet.
The BTS3900 cabinet (+24V) consists of the following components: the MRFUs, BBU, DCDU-
01, PSUs (DC/DC), and FAN unit.
Typical configuration of the BTS3900 cabinet (+24V)
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 17
Hardware Structure of the BTS3900
Hardware Structure of the BTS3900 (~220V)
The BTS3900 cabinet (~220 V) uses the external 220 V AC input. The PSUs (AC/DC) convert
the external input power into -48 V DC power and supply the -48 V DC power to the DCDU-
01.Then, the DCDU-01 distributes the -48 V DC power to each component in the cabinet.
The BTS3900 cabinet (~220 V) consists of the following components: the MRFUs,
BBU,DCDU-01, PMU, PSUs (AC/DC), and FAN unit.
Typical configuration of the BTS3900 cabinet (220 V)
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 18
Sector 1 BTS3900 Cabinet
Sector 2 PS4890 Sector 2 PS4890 Cabinet Cabinet
Sector 3 BTS3900 Hardware Components
Sector 4 BTS3900 ew Hardware
Sector 5 MRFU Working Mode
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 19
Appearance of the PS4890 Cabinet
The PS4890 cabinet is designed in compIiance with the IEC297 standard. It is a
verticaI cabinet.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 20
Hardware Structure of the PS4890
1AC/DC power system 2DCDU-04
3DCDU-03
4Copper bus bar for the negative
poles of the battery group
5Battery support plate 6Baffle plate
7Copper busbar for the positive
poles of the battery group
The PS4890 cabinet contains the power system and moduIes such as DCDU-04
and DCDU-03.
The PS4890 cabinet configured with 48V 50 Ah, 48V 92 Ah, or 48V 184 Ah battery
groups provides the foIIowing functions:
The power system converts the AC power into -48 V DC power and provides three outputs to
the battery groups, DCDU-04, and DCDU-03 through power distribution.
The DCDU-04 provides two DC outputs to the BTS3900 cabinet or other primary BTSs.
The DCDU-03 provides nine DC outputs to the transmission equipment.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 21
InstaIIation of BTS3900 and PS4890 Together
CabIe umber CabIe ame Quantity
P1P2 DCDU-04 output power cables 2
S1
Environment monitoring signal cable
between the PMU and the BBU
1
InstaIIation of BTS3900 and PS4890 in stack mode and side-by-side mode.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 22
Sector 1 BTS3900 Cabinet
Sector 2 PS4890 Cabinet
Sector 3 BTS3900 Sector 3 BTS3900 Hardware Components Hardware Components
Sector 4 BTS3900 ew Hardware
Sector 5 MRFU Working Mode
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 23
BTS3900 Components
BTS3900 Hardware incIudes:
BBU3900 Equipment
MRFU (Multi carrier Radio Filter Unit)
DCDU-01 (Direct Current Distribution Unit)
FAN Unit
GATM(GSM Antenna and TMA Control module)
SLPUSignal Lightning Protection Unit
PMU module
PSU module DC/DC
PSU module AC/DC
Power subrackDC/DC
Power subrack AC/DC
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 24
BBU3900 Equipment
The BBU3900, which features a case structure, can be instaIIed in a 19-inch-wide
and 2U-high indoor space or outdoor protective cabinet.
BBU3900 equipment incIudes:
GTMU
WMPT
WBBP
UTRP
UPEU
UEU
UELP
UFLP
UBFA
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 25
Functions of the BBU3900
As the baseband processing unit, the BBU3900 provides ports for connection
between the duaI mode base station and the BSC/RC and between the BBU3900
and the RF moduIes.
The BBU3900 has the foIIowing functions:
Provides ports for communication between the base station and the BSC/RNC.
Provides CPR ports for communication between the BBU and the RF modules.
Provides USB ports, facilitating the automatic software upgrade of the dual-mode base station
when a USB disk is inserted during software installation and data configuration.
Provides an OM channel between the base station and the LMT or the M2000 to operate and
maintain the base station.
Processes uplink and downlink data.
Manages the entire dual-mode system in terms of OM and signaling processing.
Provides the system clock.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 26
BBU3900 SIots
The sIots of the BBU3900 GSM, BBU3900 GU, and BBU3900 UMTS are the same.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 27
Board configuration principIes of the BBU3900 GSM
BBU3900 GSM board incIudes: GTMUUBFAUPEUUEIUUELP.
Board
ame
OptionaI/
Mandatory
Maximum
umber
SIot Configuration
Limitations
GTMU Mandatory 1 Slot 5 and Slot 6 Only configured in slot 5 and slot 6
UBFA Mandatory 1 UBFA Only configured in the FAN slot
UPEU Mandatory 2 PWR1 or PWR2 Preferentially configured at the PWR2
slot in the case of a single UPEU
UEU Optional 1 PWR1
UELP Mandatory 2 Slot 0 or Slot 4 n the case of less than or equal to four E1s, one UELP is
required and installed in slot 0. n the case of more than four but
less than or equal to eight E1s, two UELPs are required and
installed in slot 0 and slot 4. n the case of more than eight E1s,
the SLPU is required and the UELPs are installed in the SLPU.
Typical configuration of the BBU3900 GSM
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 28
Board configuration principIes of the BBU3900 UMTS
BBU3900 UMTS board incIudes: WMPTWBBPUBFAUPEUUEIUUELP
UFLPUTRP.
Board
ame
OptionaI/
Mandatory
Maximum
umber
SIot
Configuration Limitations
WMPT Mandatory 2 Slot 6 or Slot 7 Preferentially configured in slot 7 in the case of a single WMPT
WBBP Mandatory 4 Slot 0 Slot 3
Preferentially configured in slot 3 ,slot 0 and slot 1 in the case of the WBBP
that transmits CPR signals,slot 2 is reserved.
UBFA Mandatory 1 FAN Only configured in the FAN slot
UPEU Mandatory 2 PWR1 or PWR2 Preferentially configured in the PWR2 slot in the case of a single UPEU
UEU Optional 1 PWR1 -
UELP Optional 2 Slot 0 or slot 4
n the case of less than or equal to four E1s, one UELP is required and
installed in slot 4. n the case of more than four but less than or equal to
eight E1s, two UELPs are required and installed in slot 0 and slot 4. n the
case of more than eight E1s, the SLPU is required and the UELPs are
installed in the SLPU.
UFLP Optional 2 Slot 0 or slot 4 Preferentially configured in slot 4
UTRP Optional 6 Slot 0 Slot 5
Typical configuration of the BBU3900 UMTS
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 29
Board configuration principIes of the BBU3900 GU
Board
ame
OptionaI/
Mandatory
Maximum
umber
SIot
Configuration Limitations
WMPT Mandatory 1 Slot 7 Preferentially configured in slot 7 in the case of a single WMPT
GTMU Mandatory 1 Slot 5 and slot 6 Only configuredin slot 5 and slot6
WBBP Mandatory 4 Slot 0 Slot 3
Only configured in slot 2 and slot 3 in the case of the WBBP that transmits
CPR Signals
UBFA Mandatory 1 FAN Only configured in the FAN slot
UPEU Mandatory 2 PWR1 o PWR2 Preferentially configured in the PWR2 slot in the case of a single UPEU
UEU Optional 1 PWR1 -
UELP Optional 2 Slot 0 or slot 4
n the case of less than or equal to four E1s, one UELP is required and
installed in slot 4. n the case of more than four but less than or equal to
eight E1s, two UELPs are required and installed in slot 0 and slot 4. n the
case of more than eight E1s, the SLPU is required and the UELPs are
installed in the SLPU.
UFLP Optional 2 Slot 0 or slot 4 Preferentially configured in slot 4
UTRP Optional 4 Slot 0 Slot 4
Typical configuration of the BBU3900 GU
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 30
BBU Hardware - GTMU Board
The GSM Transmission, Timing, and Management Unit for BBU (GTMU)
controIs and manages the entire BTS in GSM mode. It provides interfaces
reIated to the reference cIock, power monitoring, OM, and externaI aIarm
coIIection.
Functions:
Controlling, maintaining, and operating the BTS. Providing fault management,
configuration management, performance management, and security management.
Monitoring the fan module and the power supply module.
Providing four routes of E1 transmission.
Providing CPR ports for the communication with the RF modules.
Distributing and managing BTS clock signals.
Providing the Ethernet port for local maintenance.
Providing clock output for testing.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 31
Board Port Connector Type Description
GTMU
CPR0
CPR5
SPF
Ports for the communication between the BBU and the RF
module; support input and output of the optical and
electrical signal.
ETH RJ45 Port for local maintenance and commissioning
FE0 RJ45
Connects the BBU to a routing device in the equipment
room through the Ethernet cable to transmit network
information.
FE1 DLC
Connects the BBU to a routing device in the equipment
room through the optical cable to transmit network
information.
USB USB Enables the automatic software upgrade from a USB disk.
TST USB Provides a reference clock for the tester.
E1/T1 DB26 female
Provides the input and output of the four E1/T1 signals
between the GTMU and the UELP or between the GTMU
and the BSC.
BBU Hardware - GTMU Board
Ports on the GTMU paneI:
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 32
BBU Hardware - GTMU Board
LEDs on the GTMU:
LED CoIor Status Description
RUN Green
ON The board is faulty.
OFF No power supply is available or the board is faulty.
ON for 1s and OFF for 1s The board is operational.
ON for 2s and OFF for 2s The OML link is abnormal.
ON for 0.125s and OFF for 0.125s The board is loading software.
ALM Red
ON A fault occurs in the running board.
OFF No alarm is generated.
ACT Green
ON The board is operational.
OFF The board is faulty.
LU0~LU3 Green
ON This link is not used.
ON for 0.125s and OFF for 0.125s A remote E1/T1 alarm is generated.
OFF This link is operational.
CPR0~CPR5
Green ON The CPR link is normal.
Red ON
The reception of the optical module is abnormal and an
alarm is generated.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 33
BBU Hardware - GTMU Board
DIP Switches:
DIP Switch
DIP Status
Description
1 2
SW1
ON ON The E1 impedance is set to 75 ohms.
OFF ON The E1 impedance is set to 120 ohms.
ON OFF The T1 impedance is set to 100 ohms.
DIP Switch
DIP Status
Description
1 2 3 4
SW2
ON ON ON ON
When four 75- ohm E1 links are faulty, all the
DP bits of S2 should be set to ON
(unbalanced mode) so that the Faults are rectified.
OFF OFF OFF OFF
All the DP bits of S2 are set to OFF (balanced
mode) by default in all modes.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 34
BBU Hardware - GTMU Board
DIP Switches:
DIP Switch
DIP Status
Description
1 2 3 4
SW5
ON ON ON ON The E1 link cannot be bypassed.
OFF ON ON OFF The E1 link of the Level 1 cascaded BTS can be bypassed.
ON OFF ON OFF The E1 link of the Level 2 cascaded BTS can be bypassed.
OFF OFF ON OFF The E1 link of the Level 3 cascaded BTS can be bypassed.
ON ON OFF OFF The E1 link of the Level 4 cascaded BTS can be bypassed.
OFF ON OFF OFF The E1 link of the Level 5 cascaded BTS can be bypassed.
DIP Switch
DIP Status
Description
1 2 3 4
SW4
ON ON ON ON The E1 link can be bypassed.
OFF OFF OFF OFF The E1 link cannot be bypassed.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 35
BBU Hardware - WMPT Board
This describes the WCDMA Main Processing and Transmission unit
(WMPT). It is the BBU3900 main controI and transmission board that
processes the signaIs and manages the resources for other boards.
The WMPT has the foIIowing functions:
Providing Operation and Maintenance (OM) functions such as configuration
management, equipment management, performance monitoring, signaling processing,
and active/standby switchover and providing OM channels connected to the OMC
(LMT or M2000).
Providing the reference clock.
Processing signaling and managing resources for other boards in the BBU.
Providing USB ports, one of which facilitates automatic base station upgraded when a
USB disk is inserted during software installation and data configuration.
Providing four E1s/T1s which support ATM and P protocols.
Providing one FE electrical port and one FE optical port which support the P protocol.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 36
Board Port Connector Type Description
WMPT
E1/T1 DB26 connector E1
FE0 RJ45 connector FE electrical port
FE1 SFP connector
FE optical port
GPS SMA connector GPS antenna
ETH RJ45 connector Commissioning Ethernet port
USB USB connector USB loading port
TEST
USB connector
USB testing port
RST Resetting the BBU
BBU Hardware - WMPT Board
Ports on the WMPT:
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 37
BBU Hardware - WMPT Board
LEDs on the WMPT:
LED CoIor Status Description
RUN
Green
ON
The power input is available, but the board is
faulty.
OFF The power supply is available.
1s ON and 1s OFF
The board in normal configuration is running
properly.
0.125s ON and 0.125s
OFF
The software is being loaded to the board, or the
board is not in use.
ALM Red
ON The board has alarms on hardware.
OFF No alarm is generated.
ACT Green
ON The board is in active mode.
OFF The board is in standby mode.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 38
BBU Hardware - WMPT Board
LEDs beside the three ports:
LED CoIor Status Description
LEDs beside the FE1
optical port
Green (LNK)
ON The connections are functional.
OFF The connections are faulty.
Green (ACK)
Blinking Data transmission is ongoing.
OFF No data transmission is ongoing.
LEDs beside the FE0
electrical port
Green (LNK)
ON The connections are functional.
OFF The connections are faulty.
Yellow (ACK)
Blinking Data transmission is ongoing.
OFF No data transmission is ongoing.
ETH
Green (LNK)
ON The connections are functional.
OFF The connections are faulty.
Yellow (ACK)
Blinking Data transmission is ongoing.
OFF No data transmission is ongoing.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 39
BBU Hardware - WMPT Board
DIP switches on the WMPT:
DIP switch DIP Bit T1 Mode 120-ohm E1 Mode 75-ohm E1 Mode
SW1
1 ON OFF ON
2 ON OFF ON
3 OFF ON ON
4 OFF ON ON
DIP switch DIP Bit BaIanced Mode UnbaIanced Mode
SW2
1 OFF ON
2 OFF ON
3 OFF ON
4 OFF ON
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 40
BBU Hardware - WBBP Board
This describes the WCDMA Baseband Process Unit (WBBP) board. It is a
mandatory board of the BBU3900 that processes baseband signaIs.
The WBBP has the foIIowing functions:
Provides the CPR ports for communication between the BBU and the RFU, and supporting
CPR ports in 1+1 backup mode.
Processes uplink and downlink baseband signals.
There're two types of WBBP board: WBBPa and WBBPb.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 41
BBU Hardware - WBBP Board
Specifications of the WBBPs:
Board umber of CeIIs umber of UL CEs umber of DL CEs
WBBPa 3 128 256
WBBPb1 3 64 64
WBBPb2 3 128 128
WBBPb3 6 256 256
WBBPb4 6 384 384
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 42
BBU Hardware - WBBP Board
LEDs on the paneI of the WBBP:
LED CoIor Status Description
RUN
Green
ON There is power supply, but the board is faulty.
OFF There is no power supply, or the board is faulty.
ON for 1s and OFF for 1s The board is running properly.
ON for 0.125s and OFF for 0.125s The board is loading software.
ALM Red
ON The board has a hardware alarm.
OFF The board is normal.
ACT Green
ON The board is running.
OFF The board is not in use.
CPR0/
CPR1/
CPR2
Red/
Green
OFF The optical module is not configured, or it is powered off.
ON (green) The CPR link is normal, and the RFU has no hardware faulty.
ON (red) The optical module is not in position, or the CPR link is faulty.
ON for 0.125s and OFF for
0.125s (red)
The RFU on the CPR link has a hardware fault, and the RFU
needs to be replaced.
ON for 1s and OFF for 1s (red)
The RFU on the CPR link has a VSWR alarm, antenna alarm, or
external alarm.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 43
BBU Hardware - UPEU Board
This describes the UniversaI Power and Environment Interface Unit
(UPEU) board. It is a mandatory board of the BBU3900 that converts -48
V or +24 V DC to +12 V DC.
The UPEU has the foIIowing functions:
Converting -48 V or +24 V DC to +12 V DC that is applicable to the boards.
Providing two ports with each transmitting one RS485 signal and another two
ports with each transmitting four dry contact signals.
Providing reverse connection protection for power cable connectors.
The UPEU is cIassified into the UniversaI Power and Environment
Interface Unit Type A (UPEA) and the UniversaI Power and Environment
Interface Unit Type B (UPEB). The UPEA converts -48 V DC to +12 V DC
and the UPEB converts 24 V DC to 12 V DC.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 44
BBU Hardware - UEIU Board
This describes the UniversaI Environment Interface Unit (UEIU) board of the
BBU3900. The UEIU transmits monitoring signaIs and aIarm signaIs from
externaI devices to the main controI board.
Ports on the UEIU:
Port Connector Type Description
MON0 RJ45 One RS485 signal
MON1 RJ45 One RS485 signal
EXT-ALM0 RJ45 Four dry contact signals
EXT-ALM1 RJ45 Four dry contact signals
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 45
BBU Hardware - UELP Board
The UniversaI E1/T1 Lightning Protection (UELP) is a universaI E1/T1
surge protection unit. The UELP is optionaIIy instaIIed in the SLPU or BBU.
Each UELP provides surge protection for four E1s/T1s.
Port
Connector Type Description
NSDE DB25
E1 transfer transmission port
OUTSDE DB26
E1 transmission port
DIP Switch
DIP Status Description
1 2 3 4
S1 ON ON ON ON
75-ohm E1 cable
OFF OFF OFF OFF
120-ohm E1 cable or 100-ohm T1 cable
The UELP has one DIP switch, which is used to seIect whether the receive
terminaI is grounded.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 46
BBU Hardware - UFLP Board
The universaI FE Iightning protection (UFLP) board is optionaIIy instaIIed
in the SLPU or BBU3900. Each UFLP supports 2-way FE surge protection.
Port Location Port Quantity Connector Type
NSDE FE0FE1 2 RJ45
OUTSDE FE0FE1 2 RJ45
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 47
BBU Hardware - UTRP Board
This describes the UniversaI Transmission Processing unit (UTRP) board. It
is a transmission extension board of the BBU3900 and provides eight
E1s/T1s and one unchanneIized STM-1/OC-3.
The UTRP has the foIIowing functions:
Providing extension ub transmission ports which support eight E1s/T1s and one
unchannelized STM-1/OC-3.
Supporting ATM and P transport.
Supporting cold backup.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 48
BBU Hardware - UTRP Board
The paneI of the UTRP configured with the UAEU or UIEU is different from
that of the UTRP configured with the UUAS.
Sub-Board Port
UAEUUniversal ATM over E1/T1 nterface and Processing Unit Ports for eight ATM over E1s/T1s
UEUUniversal P Packet over E1/T1 nterface and Processing Unit Ports for eight P over E1s/T1s
UUASUniversal Unchannelized ATM over SDH/SONET Card
Port for one unchannelized
STM-1/OC-3
The UTRP can be configured with different sub-boards to support different ports.
PaneI of the UTRP (with eight E1s/T1s)
PaneI of the UTRP (with one STM-1)
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 49
BBU Hardware - UTRP Board
LEDs on the UTRP:
LED CoIor Status Description
RUN
Green
ON
The board has power input, yet the board is
faulty.
OFF The power supply or the board is faulty.
1s ON, 1s OFF The board is running properly.
0.125s ON, 0.125s OFF Software is being loaded to the board.
2s ON, 2s OFF The board is under test.
ALM Red
ON The board is reporting alarms and is faulty.
OFF The board is running properly.
ACT Green
ON The board is in active mode.
OFF The board is in standby mode.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 50
BBU Hardware - UTRP Board
The UTRP has three DIP switches: SW1 and SW2 for setting the protection
grounding for the RX end of the E1 cabIe and SW3 for seIecting the impedance
mode for the E1 signaI cabIe.
DIP Switch DIP Bit
BaIanced
Mode
UnbaIanced
Mode
SW1
1 OFF ON
2 OFF ON
3 OFF ON
4 OFF ON
DIP Switch DIP Bit
BaIanced
Mode
UnbaIanced
Mode
SW2
1 OFF ON
2 OFF ON
3 OFF ON
4 OFF ON
DIP Switch DIP Bit
75-Ohm E1
Mode
120-Ohm E1
Mode
T1 Mode
SW3
1 ON ON OFF
2 ON ON OFF
3 ON OFF ON
4 ON OFF ON
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 51
BBU Hardware - UBFA ModuIe
This describes the UniversaI BBU Fan Unit Type A (UBFA) moduIe of the
BBU3900. The UBFA controIs the fan speed and detects the temperature of
the fan board.
LED CoIor Status Description
STATE
Green
0.125s ON, 0.125s OFF
The module is not
registered, and no
alarm is reported.
1s ON, 1s OFF
The module is
running properly.
Red
OFF No alarm is reported.
1s ON, 1s OFF
The module is
reporting alarms.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 52
BBU CabIe Connection
This describes the BBU3900
cabIes. The BBU3900
cabIes are the BBU PGD
cabIe, BBU power cabIe, E1
cabIe, E1 surge protection
transfer cabIe, CPRI opticaI
cabIe, inter-CPRI signaI
cabIe, BBU aIarm cabIe,
monitoring signaI cabIe
between the APMI and the
BBU, FE cabIe, FE surge
protection transfer cabIe,
monitoring signaI cabIe for
the EMUA, and GPS cIock
signaI cabIe.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 53
BBU3900 CabIe
BBU3900 CabIe List:
Power Cable E1 Surge Protection Transfer Cable
FE Cable
CPR Optical Cable
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 54
BBU CabIe
BBU3900 CabIe List:
(1) RJ45
connector
(2) cold-pressed
terminal
Monitoring Signal Cable Between the OFB and the BBU
Monitoring Signal Cable Between the APM and the BBU
(1) RJ45
connector
(2) cold-pressed
terminal
(3) ring terminal (4) 3PIN connector
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 55
MRFU ModuIe
The MRFU is a muIti-carrier RF fiItering unit. One MRFU supports a maximum
of 6 carriers in GSM mode, 4 carriers in UMTS mode, 6 carriers in GSM+UMTS
mode.
Functions:
mplements the direct frequency conversion technique in the transmit channel, modulates
the baseband signals to GSM RF signals; then, sends the signals to the antenna for
transmission through the duplex filter after filtering, amplifying, and combining the RF
signals. The combining can be performed as required.
Receives RF signals from the antenna and performs down-conversion, amplification,
analog-to-digital conversion, digital down-conversion, matched filtering.
Provides power sharing. mproves the network coverage, reduces the interference and
power consumption and save the device cost.
Provides power control, reverse power detection.
Provides frequency synthesis and loopback test.
Generates the CPR clock, recovers the CPR clock of lost synchronization, and detects
alarms.
Provides the function of DPD/BPD.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 56
LogicaI structure of the MRFU
The MRFU consists of the high-speed interface unit, signaI processing unit,
power ampIifier, and dupIexer.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 57
MRFU Board
Size397.25mmhj70.62mmwj305mmd
Weight10g
Ports on the paneI:
Port Type LabeI Connector Type Description
Port for
transceiving
RF signals
ANT_RXB DN connector Connecting to the antenna subsystem.
ANT_TX/RXA
CPR CPR0
SFP female connector
Connecting to the BBU, or the upper-level
RFU during the cascading.
CPR1 Connecting to the lower-level RFU during
the cascading.
nterconnection
port for RF
Receive signals
RX_NB QMA female
connector
nput port of diversity signals in the
antenna channel.
RX_OUTA
Output port of diversity signals in the
antenna channel.
Power supply port PWR 3V3 power connector
Feeding power.
Monitoring port MON RJ45 connector
RS485 Monitoringdebugging port.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 58
MRFU Board
LEDs on the MRFU paneI:
LED CoIor Status Description
RUN Green ON
The power input is normal, but the module is faulty.
OFF
There is no power supply, or the module is faulty.
1s ON, 1s OFF The module is running properly.
0.2s ON, 0.2s OFF
The software is being loaded to the module.
ALM Red 1s ON, 1s OFF A fault alarm is generated.
OFF No alarm is generated.
ACT Green ON
The module is functional and is correctly connected to the BBU.
OFF
The connection with the BBU is not set up.
VSWR Red OFF No VSWR alarm is generated.
ON
The VSWR alarm is generated on the ANT_TX/RX port.
CPR0 Red/Green ON (green) The CPR link is normal.
ON (red)
The interface module fails to receive signals.
1s ON, 1s OFF (red) The CPR link is out of lock.
CPR1 Red/Green ON (green) The CPR link is normal.
ON (red)
The interface module fails to receive signals.
1s ON, 1s OFF (red) The CPR link is out of lock.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 59
FA Unit
The FA unit, aIso caIIed the fan box moduIe, dissipates the heat in the
cabinet. One FA unit has four independent fans.
The FA unit has the foIIowing functions:
Providing forced ventilation and dissipation for the cabinet.
Supporting the temperature detection.
The FA unit supports:
Adjustment based on the temperature and adjustment controlled by the main control
unit.
Fan rotation control function. The FAN unit stops the rotation of the fans when the
ambient temperature is low.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 60
FA Unit
Ports on the paneI of the FA unit:
Connector Port Connector Type Description
Socket for
power supply
-48V connector ntroducing the -48 V DC power
Temperature
sensor port
SENSOR RJ45 Connecting the external temperature sensor
Communication port
COM OUT RJ45 Cascading the lower-level FAN unit
COM N RJ45 Connecting the main control unit
LEDs on the paneI of the FA unit:
LED CoIor Status Description
RUN Green
0.125s ON, 0.125s OFF
The module runs normally but the communication with the main
control unit is not established.
1s ON, 1s OFF
The module runs normally and the communication with the main
control unit is established.
OFF steady There is no power input, or the module is faulty.
ALM Red
1s ON, 1s OFF The module is reporting alarms.
OFF steady No alarm is generated.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 61
GATM ModuIe
The GSM antenna and TMA controI moduIe (GATM) is a moduIe that
controIs the antenna and TMA. The GATM is optionaI. The GATM is
optionaIIy instaIIed in the power cabinet or transmission cabinet when the
MRFU moduIe is configured.
The GATM has the foIIowing functions:
Controlling the RET antenna.
Supplying power to the TMA.
Reporting the RET control alarm signals.
Monitoring the current from the feeder.
Not support common TMA and RET antenna at the same time.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 62
GATM ModuIe
Ports on the GATM:
Port Connector Function
ANT0ANT5
SMA female
connector
Providing power for the RET antenna and
transmitting control signals for the RET
antenna
COM1 RJ45 connector Connecting to the BBU
COM2 RJ45 connector
Providing the extended RS485 port to be
cascaded with other devices
-48V
3W3 power
connector
Receiving the -48 V power input
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 63
GATM ModuIe
LEDs on the GATM paneI:
LED CoIor Function Status Description
RUN Green
ndicator of the
board Running
status
On for 2s and off for 2s
The power supply is normal but the
communication with the BBU is abnormal.
On for 1s and off for 1s
The board is running normally and the
communication with the BBU is normal.
Off
No power input is available, or
the module is faulty.
ACT Green
ndicator of the
Service running
status
On The ASG link is normal.
Off The ASG link is abnormal.
Blinking frequently and
irregularly
The ASG link is transmitting data.
ALM Red Alarm indicator
On
An alarm is generated, such as
an over current alarm.
Off The module runs normally.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 64
SLPU
The signaI Iightning protection unit (SLPU), which can be optionaIIy configured
with the UFLP or UELP, provides the signaI surge protection. The SLPU is an
optionaI moduIe of the BTS3900 cabinet (-48 V) or the power distribution
cabinet.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 65
Power Subrack (DC/DC)
The power subrack (DC/DC) provides access for the externaI +24 V DC. In the
power subrack, the PSU (DC/DC) converts the +24 V DC power into the -48 V DC
power, and then Ieads the -48 V DC power to the DCDU-01 over the power cabIe
through the wiring unit of the power subrack.
PSU (DC/DC).
Wiring Unit (+24 V).
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 66
Power Subrack (DC/DC) -- PSU (DC/DC)
The power suppIy unit (PSU) converts the +24 V DC into the -48 V DC that is Ied
into the direct current distribution unit.
Function:
Converting +24 V DC power to -48 V DC power and leading the -48 V DC power to the DCDU.
Monitoring alarms related to module faults (such as output overvoltage, no output, and fan
faults), alarms related to module protection (such as overtemperature protection, and input
overvoltage/undervoltage protection), and power out-of-position alarm.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 67
Power Subrack (DC/DC) -- PSU (DC/DC)
LEDs on the paneI of the PSU (DC/DC):
o. LED CoIor Status Description
1
Power
running LED
Green
ON
steady
normal
OFF
steady
There is no power input, or the input
protection tube is damaged.
2
Protection
LED
Yellow
OFF
steady
normal
ON
steady
There is an abnormal input or output
voltage, or there is an overheated or
a loosely connected rectifier module.
3 Fault LED Red
OFF
steady
normal
Blinking fan fault
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 68
Power Subrack (DC/DC) -- Wiring Unit (+24 V)
The wiring unit of the power subrack (+24 V) provides the power input wiring
terminaI, power output wiring terminaI, ALM port, and PRESET port, which are
respectiveIy connected to the +24 V input power cabIe, -48 V output power cabIe,
PSU monitoring signaI cabIe, and PSU in-position signaI cabIe.
o. ame Description
1
Wiring terminal for
introducing power
The + wiring terminal and wiring
terminal are respectively connected to
the +24 V power cable and +24 V RTN cable.
2
Wiring terminal for
supplying power
The wiring terminals LOAD1(-) and LOAD2(-)
are connected to the -48 V power cable. The
RTN(+) wiring terminal is connected to the
-48 V RTN cable.
3 PRESENT port
The PRESENT port is connected to the
in-position signal cable for the PSU.
4 ALM port
The ALM port is connected to the
monitoring signal cable for the PSU.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 69
Power Subrack (AC/DC)
The power subrack (AC/DC) consists of the PMU, PSU (AC/DC) and the wiring
unit of the power subrack (220 V). The power subrack (AC/DC) converts the 220 V
AC power to the -48V DC power.
PMU
PSU (AC/DC)
Wiring Unit (220 V)
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 70
Power Subrack (AC/DC) -- PMU
The Power and Environment Monitoring Unit (PMU) provides a comprehensive
function of power suppIy management, power distribution check, and aIarm
reporting.
The PMU performs the foIIowing functions:
Communicating with the main control unit through the RS232/RS422 serial port.
Providing comprehensive functions of power system management and battery charge and
discharge management.
Detecting and reporting water damage alarms, smoke alarms, door status alarms, and
standby Boolean value alarms, and reporting ambient humidity and temperature, battery
temperature, and standby analog values.
Detecting power distribution, reporting related alarms, and reporting dry contact alarms.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 71
Power Subrack (AC/DC) -- PMU
Ports on the PMU:
Ports on the front panel of the PMU
Backplane of the PMU
o. Pot Function
1 RS232/RS422 port Used for communication with the main control unit
3
Power test port Used for measuring power voltages by using an ordinary
multimeter through -48 V and 0 V power test holes.
4 TEST port Used for testing
5 Battery control switch
Used for powering on and off the batteries through the ON
and OFF control ports.
Press and hold the port ON for 5s to 10s until the battery
is powered on.
Press and hold the port OFF for 5s to 10s until the
battery is powered off.
NOTE
You need to insert a small round bar into the hole when
you operate the battery
6 COM port Used for connecting to the external signal transfer board
7 Backplane port Used for connecting to the backplane
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 72
Power Subrack (AC/DC) -- PMU
LEDs on the paneI of the PMU:
o. LabeI CoIor Status Description
2
RUN
Green
Blinking (ON for 1s and
OFF for 1s)
The PMU is functional, and the communication
with the main control unit is normal.
Blinking (ON for
0.125s and OFF for
0.125s)
The PMU is functional, but the communication
with the main control unit fails. f the PMU does
ot communicate with the main control unit for
one minute, the communication fails.
ON or OFF
The PMU is faulty (not in the power-on
selfcheck state).
ALM Red
ON
The base station reports at least one of the
following alarms:
Mains overvoltage or undervoltage alarm
Busbar overvoltage or undervoltage alarm
Power module alarm
Load shutdown alarm
OFF No alarm is reported.
NOTE: n 3s to 5s after the PMU is powered on, the ALM and RUN LEDs are simultaneously ON for about 3s.
Ports on the front panel of the PMU
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 73
Power Subrack (AC/DC) -- PMU
DIP Switch:
The DP switch is positioned on the right panel of the PMU. The DP switch has eight bits,
which are set to OFF before delivery.
The bits of the DP switch are in binary format. The four least significant bits (1, 2, 3, and 4) of
the DP switch define the secondary node address of the PMU. The four most significant bits
(5, 6, 7, and 8) are not defined, and they are reserved for future use.
You can set the monitoring address by setting the four least significant bits of the DP switch.
The first bit corresponds to BT0, and the fourth bit corresponds to BT3.
The monitoring address of the PMU in main cabinet must be set to 3 (1100), and that in the
extension cabinet must be set to 7 (1110).
Right panel of the PMU
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 74
Power Subrack (AC/DC) -- PSU (AC/DC)
The power suppIy unit (PSU) converts the 220 V AC power to the -48 V DC power.
Function:
Converting 220 V AC power to -48 V DC power and supplying -48 V DC power to the DCDU.
Monitoring alarms related to module faults (such as output overvoltage, no output, and fan
faults), alarms related to module protection (such as overtemperature protection and input
overvoltage/undervoltage protection), and module out-of-position alarm.
LEDs on the PSU (AC/DC) paneI:
o. LED CoIor Status Description
1 Power running LED Green
ON steady Normal
OFF steady
There are faults (such as no AC input, or
overvoltage/undervoltage of AC input) on the mains, or the
PSU has no output.
2 Protection LED Yellow
OFF steady Normal
ON steady Temperature prealarm or fan prealarm
3 Fault LED Red
OFF steady
Normal, or the PSU has no output because of faults
(such as no AC input, or overvoltage/undervoltage of
AC input) on the mains.
ON steady
There is no output because of shutdown caused by
output overvoltage or by overtemperature, fan
fault, remote shutdown, or internal problems of the PSU.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 75
Power Subrack (AC/DC) --Wiring Unit (220 V)
The wiring unit of the power subrack (220 V) provides power input wiring
terminaI, power output wiring terminaI, and wiring terminaI for the battery, to
which the input power cabIe, output power cabIe, and power cabIe for the
battery are connected respectiveIy.
o. ame Description
1
Power input wiring
terminal
The L wire is connected to the L wiring
terminal and the N wire is connected to the N
wiring terminal.
2
Power switch of the
battery
The power switch of the battery controls the
battery current.
3
Power output wiring
terminal
The -48 V power cable is connected to the
wiring terminals LOAD1(-) and LOAD2(-).
The -48 V RTN cable is connected to the RTN
(+) wiring terminal.
4
Wiring terminal for
supplying the power of
the battery
The -48 V power cable of the battery is
connected to the BAT(-) wiring terminal. The
-48 V RTN cable of the battery is connected to
the BAT(+) wiring terminal.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 76
Sector 1 BTS3900 Cabinet
Sector 2 PS4890 Cabinet
Sector 3 BTS3900 Hardware Components
Sector 4 BTS3900 Sector 4 BTS3900 ew Hardware ew Hardware
Sector 5 MRFU Working Mode
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 77
APM30H
1 HPM
2 nner air
circulation fan
3 HEUA
4 Power system
(AC/DC)
5 PDU
6 Outer air
circulation fan
7 Core of the heat
exchanger
Components of APM30H:
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 78
HEUA
The Heat Exchange Unit Type A (HEUA) monitors the fans and reports the
reIated aIarms.
Port Quantity Function
3V3 power
supply socket
1 Leading DC input power to the HEUA
4-pin ports 2
Providing the terminals for the input of power
or alarm signals of the two outer air circulation
fans
LEDs 2
ndicating the running status and alarm status
of the fans
RJ45 ports 2
Receiving two Boolean inputs
COM OUT: providing inputs of PMU
monitoring signals
COM N: providing outputs of the APM30H
alarms
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 79
HPMI
The Hert Power Monitoring Interface unit (HPMI) transfers the power monitoring
signaIs and provides ports for the input and output of various aIarm signaIs.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 80
HPMI
Ports on the HPMI:
Port Functions
TO PMU DB50 Transferring the monitoring signals of the PMU
A:1.2.3.4 Transmitting two Boolean outputs
B:1.2.3.4 Receiving two Boolean inputs
C:1.2.3.4
1.2: receiving one Boolean input
3.4: detecting the fuse alarm signals
Gate Receiving the door status alarm signals
D:1.2.3.4
1.2: receiving the AC surge protection alarm signals
3.4: receiving the DC surge protection alarm signals
Bat1 Tmp Receiving the battery temperature monitoring signals
E:1.2.3.4 Receiving two Boolean inputs
Smoke Receiving the smoke alarm signals
Water Receiving the water alarm signals
Tem Humi Receiving the temperature and humidity alarm signals
Bat2 Tmp
Providing the backup port for the input of the battery
temperature monitoring signals
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 81
Sector 1 BTS3900 Cabinet
Sector 2 PS4890 Cabinet
Sector 3 BTS3900 Hardware Components
Sector 4 BTS3900 ew Hardware
Sector 5 MRFU Working Mode Sector 5 MRFU Working Mode
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 82
The main Iimitation of MRFU
MRFU supports whoIe frequency band of PGSM 900MHz, high 45MHz
frequency band and Iow 45MHz frequency band of DCS1800MHz. High 40MHz
frequency band and Iow 40MHz frequency band of 1900MHz.
MRFU DL UL
Whole 25MHz frequency band
of 900MHz
935-960MHz 890-915MHz
Low 45MHz of 1800MHz 1805-1850MHz 1710-1755MHz
High 45MHz of 1800MHz 1835-1880MHz 1740-1785MHz
Low 40MHz of 1900MHz 1930-1970MHz 1850-1890MHz
High 40MHz of 1900MHz 1950-1990MHz 1870-1910MHz
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 83
The main Iimitation of MRFU
The instantaneous frequency bands supported by MRFU.
Power sharing doesn't support Concentric ceII, Co-BCCH, IBCA, RA sharing whiIe
static power can support these functions.
MRFU supports 2-way RX diversity. 4-way RX diversity and TX diversity are not
supported.
MRFU Type umber of TX
frequency
band of TX
umber of RX
frequency
band of RX
GSM mode 1 15MHz 2 25MHz
UMTS mode 1 20MHz 2 25MHz
GU dual mode 1 15MHz 2 25MHz
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 84
Configuration principIe of MRFU
Basic configuration principIe:
One MRFU supports a maximum cell configuration of S6.
A single BTS3900 provides a maximum of 36 carriers with the maximum cell configuration of
S12/12/12. n addition, a site configured with the BTS3900s can support a maximum of 72
carriers with the maximum cell configuration of S24/24/24.
One MRFU does not serve two cells. Each cell with a single antenna can be configured with a
maximum of two MRFUs.
MRFU supports 1-way TX and 2-way RX.
Star, chain, and ring, are supported between the BBU and the MRFUs.
When star and chain topology is adopted between the BBU and MRFUs, the MRFU supports
3 levels of cascading in a chain and thus the BBU supports a maximum of 18 (6 x 3) MRFUs.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 85
Configuration principIe Base on Limitation
of MRFU
Assign frequency:
f the frequency interval of a cell is outside the range of 15MHz, 2 MRFUs can be considered
to be used and the range of frequency for each MRFU also should be within15MHz.
Generally, it is suggested that the number of carriers should be set to 2 MRFUs averagely if 2
MRFUs are used in a cell. For example: S8 should be configured as 4+4 when 2 MRFUs are
used. S7 should be configured as 3+4 when 2 MRFUs are used. f there's limitation of
frequency band, S8 also can be configured as 3+5 or 2+6.
Frequency hopping:
Cell without frequency hopping. The cell can work normally when the range of frequency is
within 15MHz for each MRFU.
Cell with Baseband frequency hopping. The frequency range of 2 MRFUs must within 25MHz
when 2 MRFUs are used. And the range of frequency also must be within 15MHz for each
MRFU.
Cell with RF frequency hopping. The cell cannot adopt RF frequency hopping if the range of
frequency is out of 15MHz. Because the frequency range of 2 MRFUs must be within 15MHz
when 2 MRFUs are used.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 86
Configuration principIe Base on Limitation
of MRFU
Output power:
The maximum output power of MRFU is 80W.
The output power for each cell must fulfil the requirement of network plan. When the
specification doesn't fulfil the requirement, it can be improved by adding MRFUs.
The output power of all the cell must be the same because power sharing is mutually
exclusive with concentric cell. For example, S7 configured as 3+4 when 2 MRFUs are
used. The output power of MRFU configured as 3 carriers must be the same as that
of MRFU configured as 4 carriers.
Specifications of output power is Class 2, please refer to the next page.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 87
Working mode GSM TRX UMTS TRX Output power of each GSM TRX(W Output power of each UMTS TRX(W)
GSM mode
1 0 80 0
2 0 40 0
3 0 31 0
4 0 27 0
5 0 18 0
6 0 16 0
GSM+UMTS
mode
1 1 40 40
1 2 40 20
2 1 20 40
2 2 20 20
3 1 24 10
3 1 20 20
4 1 20 10
4 1 17 20
3 2 20 10
3 2 12 20
4 2 13 10
5 1 15 10
UMTS mode
0 1 0 60
0 2 0 40
0 3 0 27
0 4 0 20
Specifications of output power is CIass 2:
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 88
Antenna Configuration of MRFU
SingIe Feeder.
Two module interconnection. 1TX and 2RX.
DoubIe Feeder.
Single module. 1TX and 2RX.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 89
Transmit Mode and Receive Mode of MRFU
Transmit Mode of MRFU.
Non-combination.
Receive Mode of MRFU.
2-way RX diversity.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 90
TypicaI configuration of MRFU
SingIe MRFU.
DoubIe feeder, 1TX + 2RX.
When a dual-polarized antenna is configured, one
TX channel and two RX channels are supported.
The ANT_RXB and ANT_TX/RXA ports receive the
signals from the antenna to achieve RX diversity.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 91
TypicaI configuration of MRFU
Two moduIe interconnection.
SingIe feeder, 1TX + 2RX.
When the cell configuration is from S7 to S12, two
MRFUs need to be configured.
The ANT_TX/RXA port on each MRFU supports the
receiving and transmitting of signals. Two MRFUs
provide RX signals for each other through the RF
interconnection ports. Thus, the RX diversity is
implemented.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 92
Summary
Functions of BTS3900
Hardware structure of BTS3900
New hardware of BTS3900
Features and working mode of MRFU
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 93