Professional Documents
Culture Documents
1. Dual Trx Manual Power down Feature Licence Key has to be insatlled in the BSC. 2. Minimum CD level of the BSc should be S12 CD3.1E 3.Flexi 2+2+2 creation in BSC has to create on SEG level instead of BTS level.
ZEQC:BCF=XX,SEG=44, BTS=44:BAND=XXX
2. In 2+2+2 implementation there will be no change in cableing at BTS site, for further expansion there will change in cabling as per the diagram next page.
Configuration at BSC
SEG-1
BTS-1
BCCH BTS-1: TX1 and TX2 on separate antennas BTS-2: TX3 and TX 4 on separate antennas
BTS-2
TRX-3 TRX-4
DTRX 2
TRX-1 TRX-2
DTRX 1
TRX 1 is the BCCH TRX BTS 2 is locked prior to locking DTRX 2 (TRX 3 and 4) using a script *due of antenna hopping in use* TRX 1 and TRX 2 continue to be working on separate antennas with antenna hopping see next slide
2.For 4+4+4 implementation there will be change in cableing as discribed on next page.
Antenna 2
TX 1
TX 2
TX 1 and TX 3 on Antenna 1 TX 2 and TX 4 on antenna 2 DTRX 2 (TRX 3 and 4) to be powered off during low traffic hours DTRX 1 will supply power to DDU TRX 1 will be on Antenna 1 and TRX 2 will be on antenna 2 -> antenna hopping can still be used
Test execution:
Manual power down: Power down TRX(s) with MML command ZERS:BTS=<bts_id>,TRX=<trx_id>:,PD; Manual power up: Power up TRX(s) with MML command ZERS:BTS=<bts_id>,TRX=<trx_id>:,PU;