You are on page 1of 10

DTV Software Automatic Download Program

CONTENTS

1. S/W Download Flow Chart


2. How to connect Jig
3. S/W Automatic Download Program
4. Precaution of EPLD Download
5. Rreferences(S/W Download Algorism)

LG Electronics/ DND Division/ QA Group

#Attachment 1/10
1. S/W Download Flow Chart
Start • Use Window 98/Window Me (for Window 2000, necessary to install drive)
• Make a directory, “DTV_Download”, in “C” Drive of window explorer.
PC Setting • Save all attached files from division in this directory.
(DTV_intf.exe, lgdtvup.enc, win2000.inf, Software File by Model : *.pac, *.phc, *.jbc)

Execute Program • Execute DTV_intf.exe in “DTV_Download” Directory.

• Check whether a item to download is CPU or EPLD and select a proper jig.
Choose Item
• For CPU(Rom) - RS-232C • For EPLD - Byte Blaster
CPU EPLD

Connect PC with Set Connect PC with Set


(use Jig for CPU) (use Jig for EPLD)

Select Model Name Select Model Name • Select a model name.

Select Service Select Service • Select Service among Laboratory/Service/Product Line.

Check Connection(Port1) Check Connection(Port1) • Select Check Connection to see Communication is “Ok”.

Download Rom Download EPLD • Select “Rom” Download for CPU and “EPLD” Download for EPLD.

• Check that the New Software is normally downloaded.


Check normal Download Check normal Download
- Debug → Down Load → Erasing → Up dating → Program restart

End End • Finally turn the set on to check.

2/10 LG Electronics/DND Division/ QA Group


2. How to connect Jig

CPU(ROM) Download Jig EPLD Download Jig


Don’t use.

+
To SET To PC
(Out side) (Byte Blaster) (Connector)
(RS-232C)
< Case1 > < Case2 >
• HN-64A10/ HN-56A20
• All Model • All models except left 4 Models
• HN-64A1/ HN-56A2
To SET To SET
• RS-232C (3-Wire Configurations) (In side) (out side)
To PC
- Not Standard Type
- common use for all Models

To
RXD 2 2 TXD
PC
TXD 3 3 RXD
GND 5 5 GND
DTR 4 4 DTR
DSR 6 6 DSR
RTS 7 7 RTS
CTS 8 8 CTS

DB 9 DB 9

3/10 LG Electronics/DND Division/ QA Group


3. S/W Automatic Download Program usage-1

< Main screen > --- execute DTV_intf.exe. screen outline

1.Automatic execution program to download


EPLD & CPU S/W for DTV drive.
1) screen classification : Main screen outline

screen explanation

1. The constitution of the screen

- Interface : model input & related files info


- Communication : Serial Port’s connection &
baud rate
- Menu for department : 3 menus such as
Laboratory,Service,Product Line

- Down Status : the status of Download


progress
- Window : the contents communication with
Set

precaution
1.Program File(DTV_intf.exe), Encryption
Environment File(lgdtvup.enc),
Download File shall be in the
same directory.

4/10 LG Electronics/DND Division/ QA Group


3. S/W Automatic Download Program usage-2

2) screen classification : Main > Interface

① select a model

Click on the dropdown list so models are displayed and select a model
And in ROM File and EPLD File, the file name is automatically displayed by selecting a model.

※ Environment file(lgdtvup.enc): In fact it has the info by model as below but for security, we can not see this info in PC
due to file encryption.

Model Password RomFileName EPLDFileName Baud Rate DownLoad Ver-Type Version Version-up
------15-------+-----15-------+----20-------------+---20--------------+--10-----+--10-----+--10-----+---10----+------16-
HN-64A1 HN64A10 32w_290.pak bill_top_ver1.jbc 57600 case1 case1 2.00 10:23/07/0
HN-56A2 HN64A10 32w_290.pak bill_top_ver2.jbc 57600 case1 case1 2.50 10:23/07/0
HN-32Q8 HN61A4 rom.pak bill_top_ver1.jbc 115200 case2 case2 2.00 11:14/05/0
HN-61A40 HN61A40 61a40_160.pak ready_top.jbc 115200 case2 case2 2.00 11:14/05/0
HN-61A40R HN61A40R Flash.phc ready_top.jbc 57600 case1 case1 2.00 11:14/05/0
RN-60SZ10H m Flash.phc ready_top.jbc 57600 case1 case1 2.00 11:14/05/0

5/10 LG Electronics/DND Division/ QA Group


3. S/W Automatic Download Program usage-3

3) screen classification : Main > department category

① Service

It has the function as below.


- EPLD Download : Download EPLD related S/W. File Type is jbc.
- Connection Check : Check the connection between Set and PC to download CPU S/W.
- Version Check : Before downloading CPU S/W, able to compare current version with the latest version.
( Latest Version : Latest CPU S/W Version , Set Version :Set CPU S/W Version connecting to PC )

- ROM Download : After checking the version, use this to download CPU S/W. And without checking others, it is
possible to complete the download only with this button.

* In the service department, there is no chance to use Laboratory or Product Line.

6/10 LG Electronics/DND Division/ QA Group


3. S/W Automatic Download Program usage-4

4) screen classification : Main > Communication

① Communication
• Connection : check the connection between PC & Set.
• PORT : change Port . Default is COM1.
• Baud Rate : general baud rate is 57600 and it is changed automatically when downloading in accordance with CPU type.
( 1st generation: 57600, 2nd generation : 115200 )

5) Others (Download status & Communication contents)


• Download Status

➣ Download Flow Chart

• Window (Window)

Debug → Down Load → Erasing

→ Up dating → Program restart

7/10 LG Electronics/DND Division/ QA Group


4. Precaution of EPLD Download

1) User operating system & Download cable check

<window before downloading EPLD > < Message of Download cable & operating system>

1) Windows 98 user:
- do not have to install drive, check the cable for EPLD S/W Download and click on ‘OK’ in the message box.

2) Windows 2000 user:

- must install driver, see the next page to install driver.

8/10 LG Electronics/DND Division/ QA Group


4. Precaution of EPLD Download

2) Driver Installation Procedures (Windows 2000 user)

Follow the below procedures.


• Open the Control Panel (start menu -> setting ->control panel).
• To start the Add/Remove Hardware Wizard, double click on the Add/Remove Hardware icon and
click Next to continue.
• In the Hardware Task Panel, select the Add tool/Troubleshoot radio button and click Next to
continue.
( Windows 2000 will search for the new Plug –in-Play hardware)
• In the Select Hardware Device, select Add New Device and click Next to continue..
• Select “No, I want to select the hardware from the list’ and click on the radio button and click
Next to continue.
• In the Hardware Type window, select sound, vide and game controller and click Next to continue.
• In the Select Device Driver window, click Have Disk.
• In the Install Disc window, set the whole path of win2000.inf( ex. \DTV_Upgrade) and click Confirm.
• In the ‘Digital Signature not found’ dialogue box, click Yes.
• In the Select Device Driver window, select Altera ByteBlaster and click Next.
• In the Start Hardware Installation window, click Next.
• In the Digital Signature Not Found dialog box, click Yes to continue the installation.
• In the Competethe Add/Remove Hardware Wizard window, click Finish.
• Reboot the system to apply the new settings.

9/10 LG Electronics/DND Division/ QA Group


5. References(S/W Download Algorism)

Start Data process Sample

1st generation 2nd generation remark


Select Model
HN-61A40R HN-32Q8 Environment file
Input Password
HN61A40R HN61A4 Environment file
Enter Debug Mode
d d
Check Version
90 fe
Output Version

Enter Download Mode


14 f0
Select Serial Port
3
Select File Type
b(Binary)

Download case2
type?
case1 case2 Environment file
case1
57600 Download 115200 Download

Unpacking

Rebooting
※ The environment file in the remark category reads the data from lgdtvup.enc
And the rest is processed with program internal algorism.
End

10/10 LG Electronics/DND Division/ QA Group